XtremIO: Alert: IPMI reported abnormal fan sensor indications on Storage Controller

Summary: IPMI reported abnormal fan sensor indications on Storage Controller.

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Symptoms

Raises Alert:
 
IPMI reported abnormal fan sensor indications.                                         major    Wed Jan 20 15:28:59 2016 StorageController X1-SC1        1     xtremio_array 1     node_fan_level_6_critical outstanding          0401206

 

Cause

The cause of this can be related to a fan issue in the storage controller mentioned.

Resolution

1. Connect to the XMS and issue command: show-storage-controllers-sensors
 
Example:
X1-SC1                  1     fan          System Fan 6B     level_1_clear 7920.0  0.0             1980.0          RPM
X1-SC1                  1     fan          System Fan 6A     level_1_clear 7440.0  0.0             1922.0          RPM
X1-SC1                  1     fan          System Fan 5B     level_1_clear 7920.0  0.0             1980.0          RPM
X1-SC1                  1     fan          System Fan 5A     level_1_clear 7440.0  0.0             1922.0          RPM
X1-SC1                  1     fan          System Fan 4B     level_1_clear 7980.0  0.0             1980.0          RPM
X1-SC1                  1     fan          System Fan 4A     level_1_clear 7750.0  0.0             1922.0          RPM
X1-SC1                  1     fan          System Fan 3B     level_6_critical 0.0  0.0             1980.0          RPM
X1-SC1                  1     fan          System Fan 3A     level_1_clear 7750.0  0.0             1922.0          RPM
X1-SC1                  1     fan          System Fan 2B     level_1_clear 7920.0  0.0             1980.0          RPM
X1-SC1                  1     fan          System Fan 2A     level_1_clear 7564.0  0.0             1922.0          RPM
X1-SC1                  1     fan          System Fan 1B     level_1_clear 8220.0  0.0             1980.0          RPM
X1-SC1                  1     fan          System Fan 1A     level_1_clear 7750.0  0.0             1922.0          RPM


2. If found, the fan speed is 0 RPM, and or the status is showing "level_6_critical." Contact Dell support.
 

Affected Products

XtremIO Family, XtremIO HW Gen2 400GB, XtremIO HW Gen2 400GB Encrypt Capbl, XtremIO HW Gen2 400GB Encrypt Disable, XtremIO HW Gen2 400GB Exp Encrypt Disable, XtremIO HW Gen2 400GB Expandable, XtremIO HW Gen2 800GB Encrypt Capbl , XtremIO HW Gen2 800GB Encrypt Disable, XtremIO HW Gen3 40TB ...

Products

XtremIO HW Gen3 40TB Encrypt Disable, XtremIO HW X2-R, XtremIO HW X2-R Encrypt Disable, XtremIO HW X2-S, XtremIO HW X2-S Encrypt Disable, XtremIO HW X2-T, XtremIO HW X2-T Encrypt Disable, XtremIO X1, XtremIO X2
Article Properties
Article Number: 000030517
Article Type: Solution
Last Modified: 17 Apr 2026
Version:  6
Find answers to your questions from other Dell users
Support Services
Check if your device is covered by Support Services.