Storage Center has reported a faulted power supply unit (PSU). Follow these steps to isolate the problem.

  1. Check the PSU LEDs. Check the AC power status indicator first. If the green LED is off, and both the AC power fault and DC power fault indicators are amber perform these troubleshooting steps otherwise, go to step 2.

    1. Verify that the power switch is turned on.

    2. Reseat the power cable on both ends.

    3. Verify that the power outlet is good, either by plugging in a different device or using a different port on the power source.

    4. Test with a different power cable.

    5. Reseat the PSU.

  2. If the amber DC power fault indicator is the only LED illuminated, it indicates that the PSU is not fully seated into the chassis. Reseat the PSU, otherwise go to step 3.

  3. Any other combination of fault LEDs, reseat the PSU.

If the PSU is still reported as faulted, contact your service provider.