PowerEdge: M1000e AG switch port in persistentdisable state, with error: "Configuration is not capable"
Summary: PowerEdge M1000e: AG switch port in persistentdisable state.
This article applies to
This article does not apply to
This article is not tied to any specific product.
Not all product versions are identified in this article.
Symptoms
Impact:
F-port in persistentdisable state and unable to change to enable state.
Environment:
DELL PowerEdge M1000e
Brocade M6505 in Access Gateway mode
Issue:
F-port stuck in persistent disable state.
After reboot of the Access Gateway, the port changed to a persistent disable state.
Example:
switchshow : switchName: switchname switchType: 130.0 switchState: Online switchMode: Access Gateway Mode switchWwn: 10:00:00:00:00:00:00:00 switchBeacon: OFF Index Port Address Media Speed State Proto ================================================== <truncated> 6 6 010600 cu N16 In_Sync FC Disabled (Persistent) 7 7 010700 cu N16 Online FC F-Port <pwwn> 8 8 010800 cu N16 In_Sync FC Disabled (Persistent)
Error after trying to change to persistentenabling of the port:
switchname:admin> portcfgpersistentenable 8 Port 8: portcfgpersistentenable failed. Configuration is not capable(8).
Cause
Port stuck in persistentdisable configuration.
Resolution
Procedure:
- Collect the
ag --mapshow outputto see where the f-ports are mapped to which N-port. - Set the port back to factory default with the command
<portcfgdefault (port no) >.
Example: portCfgDefault 8
- Check the port status with the command switchshow if the port is out of
persistentdisablestate.
Example: After
portcfgdefault command, the status changed to: In_Sync FC Disabled (No mapping for F-Port)
- Enable the port with the command:
portenable (port no). - Map the port back to the original N-port with command:
ag –mapadd (n-port) (f-port).
Example:
ag --mapadd 20 "8"
- Check if the port is mapped to the N-port with the command:
ag --mapshow. - Check the port status with the command:
switchshow. Expect the port to be online.
Example:
Online FC F-Port
Affected Products
Brocade M6505, PowerEdge M1000EArticle Properties
Article Number: 000185988
Article Type: Solution
Last Modified: 12 Jun 2025
Version: 3
Find answers to your questions from other Dell users
Support Services
Check if your device is covered by Support Services.