Customer is seeing excessive NVMe error in the error log
Summary: Customer says they are seeing Excessive nvme login on powermax volumes. Errors to include cpu9:2097845)PowerPath: Invalid length RTPG Descrptr Vol 60000970000197601947533030383435 StSys 000197601947 ...
This article applies to
This article does not apply to
This article is not tied to any specific product.
Not all product versions are identified in this article.
Symptoms
Customer says they are seeing Excessive nvme login on powermax volumes.
Streaming error seen,
Streaming error seen,
2023-02-20T05:01:38.229Z cpu13:2097846)WARNING: NvmeScsi: 172: SCSI opcode 0x4d (0x45b9e32eba88) on path vmhba65:C0:T1:L2134 to namespace eui.19475330303835370000976000019760 failed with NVMe error status: 0x2 translating to SCSI error 2023-02-20T05:01:38.229Z cpu13:2097846)WARNING: H:0x0 D:0x2 P:0x0 Valid sense data: 0x5 0x24 0x0
Also,
2023-02-20T05:01:50.326Z cpu9:2097845)PowerPath:Invalid length RTPG Descrptr Vol 60000970000197601947533030383435 StSys 000197601947
Cause
The reason that we are seeing Invalid length RTPG descriptor messages in the logs is because of a problem in the scsi translation layer. Wherein length does not account for extended header size of 4 bytes in the extended header format. So the overall length is less by 4 bytes. RTPG payload size is 24 bytes, but VMware is sending 28 bytes because of the extended header format.
Resolution
First set of errors are benign and can be ignored. second error has been addressed by VMware engineering. (DCPN 109006) and also powerpath EE (PPVM-2104) is aware of this.
Fix was firstly to be incoporated into esxi 8.x series but this customer has an issue with their esxi 7.*. VMware engineering team has confirmed that the fix for this issue will be available in 7.0 u3L release (7.0p07) which is expected to release in march end (tentative) and in 8.0 u1 release.
Fix was firstly to be incoporated into esxi 8.x series but this customer has an issue with their esxi 7.*. VMware engineering team has confirmed that the fix for this issue will be available in 7.0 u3L release (7.0p07) which is expected to release in march end (tentative) and in 8.0 u1 release.
Affected Products
PowerMax, PowerPath/VE for VMware, VMware ESXi 7.xArticle Properties
Article Number: 000210866
Article Type: Solution
Last Modified: 21 Mar 2023
Version: 2
Find answers to your questions from other Dell users