PowerMax: Health Check in Embedded Unisphere is Failing with "The request to run config changes failed"
Summary: Health check in Embedded Unisphere 9.2.3.22 is failing with "Config change. The request to run config changes failed, see the SYMAPI logs for more information."
This article applies to
This article does not apply to
This article is not tied to any specific product.
Not all product versions are identified in this article.
Symptoms
- Ran Health check from the backend, it came clean. There were no hardware failures or failed scripts.
- Deleted failed health checks in Job list and tried running the HC in Unisphere, still it failed with the below error.

From SYMAPI logs:
07/04/2023 06:13:26.414 30549 run health check; 07/04/2023 06:13:26.414 30549 } 07/04/2023 06:13:28.830 30549 Initiating COMMIT of maintenance changes................Queued. 07/04/2023 06:13:29.849 30549 155 EMC:UNIVMAX cfgLogSymmwinError SymConfigChangeControl call to cfgControlPoll for Polling failed with code: SWRS_ERR 07/04/2023 06:13:29.854 30549 SID 00019790XXXX: Script handling returned sts code 0x23: Message 0x00000023 SwProc.exe failed. 07/04/2023 06:13:29.856 30549 SID 00019790XXXX: API msg : The Configuration Server failed to complete the operation. Please examine the SYMAPI log file for details 07/04/2023 06:13:29.856 30549 COMMIT monitoring failed 07/04/2023 06:13:31.552 30549 Terminating session with configuration server.............Done. 07/04/2023 06:14:03.864 30549 156 EMC:UNIVMAX iSymConfigChangeSess Starting a local Maintenance session for SID 00019790XXXX, symapi V9.2-2637 (3.6) ucode 5978 07/04/2023 06:14:04.155 30549 Establishing session with Local cfg srvr (00019790XXXX)...Established. 07/04/2023 06:14:04.155 30549 Session ID 16811264 (0x01008500) 07/04/2023 06:14:04.259 30549 156 EMC:UNIVMAX iSymConfigChangeCont iSymConfigChangeControl: session_id = 1 07/04/2023 06:14:04.264 30549 { 07/04/2023 06:14:04.264 30549 run health check; 07/04/2023 06:14:04.264 30549 } 07/04/2023 06:14:06.660 30549 Initiating COMMIT of maintenance changes................Queued. 07/04/2023 06:14:07.635 30549 156 EMC:UNIVMAX cfgLogSymmwinError SymConfigChangeControl call to cfgControlPoll for Polling failed with code: SWRS_ERR 07/04/2023 06:14:07.640 30549 SID 00019790XXXX: Script handling returned sts code 0x23: Message 0x00000023 SwProc.exe failed. 07/04/2023 06:14:07.640 30549 SID 00019790XXXX: API msg : The Configuration Server failed to complete the operation. Please examine the SYMAPI log file for details
Cause
Unknown
Resolution
- Reboot MMCS
- Delete the failed Health check tasks in the Job list and refresh the Unisphere.
- Re-run Health check in Unisphere.
Affected Products
Unisphere for PowerMaxArticle Properties
Article Number: 000215585
Article Type: Solution
Last Modified: 31 Jan 2024
Version: 4
Find answers to your questions from other Dell users
Support Services
Check if your device is covered by Support Services.