Connectrix Brocade B-Series: On DS-6620B switches there is a chance that transient pcs errors are logged.

Summary: Transient PCS errors logged on middle port of the DS-6620B switches with FOS v8.2.3b, 8.2.3c1 and v9.1.1c

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Symptoms

Impact:

Unnecessary SFP / cable troubleshooting on the middle ports of the DS-6620B.

 

Environment:

Dell Hardware: Connectrix DS-6620B

Brocade Software: Fabric OS 8.2.3b

Brocade Software: Fabric OS 8.2.3c1

Brocade Software: Fabric OS 9.1.1c

 

Problem:

There is an issue that triggers the PCS error counter to increase and a message to be logged in the errdump, these errors are transient.

That initiates troubleshooting to be done on the port and cable, (Swapping and/or cleaning optics, cables.)

 

Example:

In the errdump:

[C4-1023], 88355/1719, CHASSIS, WARNING, G620, Single RDY/Frame Loss detected and recovered on Slot 0,Port 34(26) rdy(0x1)/frame(0x0)

 

 

In the porterrshow:

/fabos/cliexec/porterrshow:

          frames      enc    crc    crc    too    too    bad    enc   disc   link   loss   loss   frjt   fbsy  c3timeout    pcs    uncor

       tx     rx      in    err    g_eof  shrt   long   eof     out   c3    fail    sync   sig                  tx    rx     err    err



34:    1.2g 700.9m   0      0      0      0      0      0      0      0      0      0      0      0      0      0      0     98      8 

 

Note that:

The problem is only on the middle ports of the switch (ports 17-34).

The listed errors stay with the port and do not follow the cable and also after SFP swap the errors return.

Cause

There is a DEFECT in the Fabric OS code where the SFP electrical RX signal is over emphasized for the middle ports (ports 17-34), causing the pcs errors to increase on the physical switch port.

Brocade fixed this by optimizing the electrical RX signal of the SFP for those middle ports.

 

Brocade DEFECT FOS-860049

 

Resolution

Fix:

Upgrade to FOS v9.2.0c or higher.

Upgrade to FOS v9.2.2 or higher.

Once upgrade is complete, they recommend disable / enable the affected ports that had PCS errors.

(This will impact the attached device, make sure redundancy is in place.)

 

Brocade DEFECT FOS-860049

Affected Products

Connectrix, Connectrix DS 6620B
Article Properties
Article Number: 000256031
Article Type: Solution
Last Modified: 12 Mar 2025
Version:  2
Find answers to your questions from other Dell users
Support Services
Check if your device is covered by Support Services.