Løsningsaktiverer: Symclone-etablering mislykkes, når SRDF/A kører

Summary: Kunne ikke udføre den trinvise symclone-etablering, når R2-enheder som kilde er i en konsistent tilstand.

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Symptoms

Når SRDF-enheder er indstillet til Async-tilstand, vil R2-enheder være i en konsistent tilstand, så symclone-etableringen mislykkes som vist nedenfor: 
 
symrdf -g test_dg que 
 
Device Group (DG) Name       : test_dg
DG's Type                    : ANY
DG's Symmetrix ID            : 000xxxxxxxxx    (Microcode Version: 5876)
Remote Symmetrix ID          : 000yyyyyyyyy    (Microcode Version: 5876)
RDF (RA) Group Number        :  57 (38)         
Target (R2) View                         Source (R1) View     FLAGS
---------------------------------    ------------------------ ----- ------------
               ST                 LI       ST
Standard        A                  N        A
Logical  Sym    T R1 Inv  R2 Inv   K Sym    T R1 Inv  R2 Inv        RDF Pair
Device   Dev    E Tracks  Tracks   S Dev    E Tracks  Tracks  MCES  STATE
--------------------------------- -- ------------------------ ----- ------------
SRC01693  01693 WD      0       0 RW 04C32 RW       0       0 AX.E  Consistent
SRC03AA3 03AA3 WD       0       0 RW 02FCB RW       0       0 AX.E  Consistent 
Total             ------- -------             ------- -------
  Track(s)              0       0                   0       0
  MB(s)               0.0     0.0                 0.0     0.0 
Legend for FLAGS: 
(M)ode of Operation : A = Async, S = Sync, E = Semi-sync, D = Adaptive Copy Disk Mode
                    : W = Adaptive Copy WP Mode, M = Mixed, T = Active
(C)onsistency State : X = Enabled, . = Disabled, M = Mixed, - = N/A
(E)xempt            : X = Enabled, . = Disabled, M = Mixed, - = N/A
R1/R2 Device (S)ize : E = R1 EQ R2, 1 = R1 GT R2, 2 = R2 GT R1, - = N/A
symclone -g test_dg   establish -consistent -tgt 
 
Execute 'Incremental Establish' operation for device group
'test_dg' (y/[n]) ? y 
'Incremental Establish' operation execution is in progress for
device group 'test_dg'. Please wait... 

The request is not allowed for SRDF/A-capable devices in async mode

Cause

Når en R2-enhed i asynkron tilstand bruges som kloningskilde, mislykkes
symclone establish-kommandoen, fordi en "establish" udfører "genskab/aktiver" øjeblikke fra hinanden. Det indledende eksemplar vil aldrig få en chance for at være effektiv.

Men -precopy eller -copy kan bruges til at opretholde SRDF/A-konsistenssessionen under oprettelse af en klonet kopi.

Resolution

For at oprette en ensartet klonet kopi skal du udføre kommandoerne "genskab/aktiver" separat en smule fra hinanden i stedet for en enkelt etableringskommando, der inkluderer begge handlinger samtidig. 

Eksempel nedenfor: 
 
symclone -g "test_dg" recreate -precopy -tgt
symclone -g "test_dg" activate -tgt -consistent

Dette ville effektivt fungere i stedet for symclone-etableringen.

Affected Products

PowerMax, Solutions Enabler Series, VMAX, VMAX All Flash, VMAX3 Series
Article Properties
Article Number: 000208281
Article Type: Solution
Last Modified: 16 مايو 2026
Version:  2
Find answers to your questions from other Dell users
Support Services
Check if your device is covered by Support Services.