PowerScale:Var 分区扩展问题
Summary: /var 分区扩展可能会导致 Isilon On-Cluster Analysis 工具 (IOCA) 中出现警告消息。这些问题与出于维护目的卸下驱动器底座时可能发生的节点崩溃有关。
This article applies to
This article does not apply to
This article is not tied to any specific product.
Not all product versions are identified in this article.
Symptoms
当前 Isilon On-Cluster Analysis 工具 (IOCA) 脚本生成以下与
当节点启动时,查看
/var 分区:
System Partition Free Space FAIL CRITICAL: The following nodes have /var mirrors of different sizes: 1-10 INFO: Please reference KB 000213248 (https://www.dell.com/support/kbdoc/000213248) for further information. INFO: For more information refer to KB article 000041465 found at https://www.dell.com/support/kbdoc/000041465.或:
Mirror Status FAIL CRITICAL: The mirror pair for var1 appear to be in the same fault domain on nodes: 1-10. CRITICAL: The following nodes have /var mirrors of different sizes: 1-10 INFO: Please open a Technical Support Service Request and reference this failure within the description. INFO: Please refer to KB 000213248 (https://www.dell.com/support/kbdoc/en-us/000213248) for further information.如果忽略,则在驱动器或底座更换过程中,第 6 代或第 6 代 MLK 节点上可能会发生死机。
当节点启动时,查看
/var/log/messages 节点的文件显示类似于以下内容的错误和死机消息:
(da21:pmspcbsd0:0:22:0): pccb 0xfffffe8543174480, ccb 0xfffff80e31347000: ccbStatus 3, scsiStatus 5 (da22:pmspcbsd0:0:23:0): pccb 0xfffffe8543151fe0, ccb 0xfffff807c4753000: ccbStatus 3, scsiStatus 5 (da21:pmspcbsd0:0:22:0): WRITE(10). CDB: 2a 00 00 04 dd 44 00 00 04 00 (da21:pmspcbsd0:0:22:0): CAM status: CCB request aborted by the host (da22:pmspcbsd0:0:23:0): WRITE(10). CDB: 2a 00 00 04 dd 44 00 00 04 00 (da21:pmspcbsd0:0:22:0): Retrying command, 3 more tries remain (da22:pmspcbsd0:0:23:0): CAM status: CCB request aborted by the host (da21:pmspcbsd0:0:22:0): pccb 0xfffffe8543151fe0, ccb 0xfffff80e31347000: ccbStatus 3, scsiStatus 2 (da22:pmspcbsd0:0:23:0): Retrying command, 3 more tries remain (da21:pmspcbsd0:0:22:0): cam_periph_error: SSQ_LOST removing device ccb 0xfffff80e31347000 status 0x8 flags 0x2 (da22:pmspcbsd0:0:23:0): pccb 0xfffffe8543151fe0, ccb 0xfffff807c4753000: ccbStatus 3, scsiStatus 2 (da21:pmspcbsd0:0:22:0): Invalidating pack (da22:pmspcbsd0:0:23:0): cam_periph_error: SSQ_LOST removing device ccb 0xfffff807c4753000 status 0x8 flags 0x2 (da22:pmspcbsd0:0:23:0): Invalidating pack (da21:pmspcbsd0:0:22:0): removing device entry (da21:pmspcbsd0:0:22:0): Periph destroyed panic @ time 1681142660.493, thread 0xfffffe874ee12000: mirror/var1: all devices failed (read, offset 1304707072, length 0) time = 1681142660 cpuid = 3, TSC = 0x5e76342b8e8e59 Panic occurred in module kernel loaded at 0xffffffff80200000: Stack: -------------------------------------------------- kernel:g_mirror_worker+0x251f kernel:fork_exit+0x82 -------------------------------------------------- Disabling swatchdog Dumping stacks (40960 bytes)
Cause
在版本 9.2.1.16 及更高版本、9.4.0.6 及更高版本以及 9.5.0.0 及更高版本中,OneFS 在升级期间将 /var分区大小扩展到 2 GB。扩展过程可能会导致触发这些消息或事件。
与镜像对位于同一容错域中的相关消息特定于 Gen6 和 Gen6 MLK 节点(A200、A2000、A300、A3000、H400、H500、H600、H5600、H700、H7000、F800 和 F810)。扩展可能无法正确验证分区容错域,从而将两个分区都用于
任一
截断
var 分区的不同大小可能会影响运行 OneFS 9.x 的任何 Isilon 或 PowerScale 节点类型。扩展
要确定此问题是否影响群集上的 LKG 分区,请使用以下命令:
在上面的示例中,lab-2 的
与镜像对位于同一容错域中的相关消息特定于 Gen6 和 Gen6 MLK 节点(A200、A2000、A300、A3000、H400、H500、H600、H5600、H700、H7000、F800 和 F810)。扩展可能无法正确验证分区容错域,从而将两个分区都用于
/var 在同一驱动器底座中的驱动器上进行镜像。如果已装载的两个镜像都适用于 /var 分区位于底座中。
任一
mirror/var0 或 mirror/var1 充当活动 /var 随时进行分区镜像。从示例中的死机消息中,我们看到 /mirror/var1 是活动镜像。看看 gmirror status 和 isi devices drive list 节点的命令输出:
截断
status 命令输出:
gmirror status mirror/var1 COMPLETE da14p3 (ACTIVE) <<<< da13p3 (ACTIVE) <<<<The
drive list 命令输出:
isi devices drive list Lnn Location Device Lnum State Serial Sled --------------------------------------------------------- 21 Bay 1 /dev/da1 15 L3 xxxxxxxxxxxx N/A 21 Bay 2 /dev/da2 16 L3 xxxxxxxxxxxx N/A 21 Bay A0 /dev/da5 12 HEALTHY xxxxxxxx A 21 Bay A1 /dev/da4 13 HEALTHY xxxxxxxx A 21 Bay A2 /dev/da3 14 HEALTHY xxxxxxxx A 21 Bay B0 /dev/da8 9 HEALTHY xxxxxxxx B 21 Bay B1 /dev/da7 10 HEALTHY xxxxxxxx B 21 Bay B2 /dev/da6 11 HEALTHY xxxxxxxx B 21 Bay C0 /dev/da11 6 HEALTHY xxxxxxxx C 21 Bay C1 /dev/da10 7 HEALTHY xxxxxxxx C 21 Bay C2 /dev/da9 8 HEALTHY xxxxxxxx C 21 Bay D0 /dev/da14 3 HEALTHY xxxxxxxx D <<<< 21 Bay D1 /dev/da13 4 HEALTHY xxxxxxxx D <<<< 21 Bay D2 /dev/da12 5 HEALTHY xxxxxxxx D 21 Bay E0 /dev/da17 0 HEALTHY xxxxxxxx E 21 Bay E1 /dev/da16 1 HEALTHY xxxxxxxx E 21 Bay E2 /dev/da15 2 HEALTHY xxxxxxxx E ---------------------------------------------------------在此示例中,
/mirror/var1 基于驱动器 D0 和 D1 构建。从群集中移除 D 底座时,由于无法访问 /var 文件系统。
var 分区的不同大小可能会影响运行 OneFS 9.x 的任何 Isilon 或 PowerScale 节点类型。扩展
/var 仅扩展活动的 /var 系统上的分区。最后一个已知好 (LKG) 分区保持原始大小。如果处于活动状态 /var 分区扩展并填充到超过 50%,如果必须轮换分区进行维护,这可能会导致问题。
要确定此问题是否影响群集上的 LKG 分区,请使用以下命令:
# isi_for_array -sX 'gmirror list var0 var1' | grep -A20 mirror | egrep "var|Media"示例:
lab-1# isi_for_array -sX 'gmirror list var0 var1' | grep -A20 mirror | egrep "var|Media" lab-1: 1. Name: mirror/var0 lab-1: Mediasize: 2147479552 (2.0G) lab-1: Mediasize: 2147483648 (2.0G) lab-1: Mediasize: 2147483648 (2.0G) lab-2: 1. Name: mirror/var0 lab-2: Mediasize: 2147479552 (1.0G) <<<< lab-2: Mediasize: 2147483648 (1.0G) <<<< lab-2: Mediasize: 2147483648 (1.0G) <<<< lab-3: 1. Name: mirror/var0 lab-3: Mediasize: 2147479552 (2.0G) lab-3: Mediasize: 2147483648 (2.0G) lab-3: Mediasize: 2147483648 (2.0G) lab-4: 1. Name: mirror/var0 lab-4: Mediasize: 2147479552 (2.0G) lab-4: Mediasize: 2147483648 (2.0G) lab-4: Mediasize: 2147483648 (2.0G) ....如果任何设备的大小为 (1.0G),则它会受到影响。
在上面的示例中,lab-2 的
var0 分区受到影响,必须修复。重新运行命令 var1 以确定它是否也受到影响。Resolution
仅容错域问题的永久修复程序包含在以下代码版本中:
- OneFS 9.5.0.6
- 9.4.0.16
- 9.2.1.25
不同大小的 /var 分区的永久修复正在处理中。要解决此问题,请按照脚本化过程操作。如果您无法升级,请按照脚本化过程进行操作。
注意: 在 以合规性模式运行的群集上,无法手动或使用以下脚本解决此问题。如果群集处于 SmartLock 合规性模式,则可以通过升级到上面列出的 OneFS 版本来修正此问题。如果无法升级以修复此问题,请联系 戴尔支持 并请求 DA 修补程序。有一个脚本可用于解决此问题。请联系 戴尔支持 以接收文件,然后按照以下说明进行操作。
要使用脚本,请执行以下操作:
- 将脚本和 md5 文件下载到群集。将文件复制到
/ifs/data/Isilon_Support在群集上,确认 MD5 哈希与 MD5 文件中的哈希匹配:
Lab-1# mv var_mirror_repair.sh /ifs/data/Isilon_Support/ Lab-1# mv var_mirror_repair.md5 /ifs/data/Isilon_Support/ Lab-1# md5 /ifs/data/Isilon_Support/var_mirror_repair.sh MD5 (/ifs/data/Isilon_Support/var_mirror_repair.sh) = 0881afeeb39fdaf02e2a90d784e4ed21 Lab-1# # cat /ifs/data/Isilon_Support/var_mirror_repair.md5 0881afeeb39fdaf02e2a90d784e4ed21
- 如果哈希不匹配,请从 FTP 站点下载脚本,然后再次将其复制到群集。如果哈希匹配,请以 root 用户身份运行以下命令:
lab-1# sh /ifs/data/Isilon_Support/var_mirror_repair.sh
- 该脚本通常需要 5-10 分钟的时间来运行。在大型(30+ 节点)或繁忙的群集上可能需要更长时间。脚本完成后,它将报告是否成功或是否存在问题。
启动脚本时,您会看到以下输出:
Lab-1# sh /ifs/data/Isilon_Support/var_mirror_repair.sh Full output can be found at: /ifs/data/Isilon_Support/var_mirror_repair.FULL_CLUSTER.2023-10-19T092522.csv Status: 0/4 Nodes checked, 0/4 var0 partitions, 0/4 var1 partitions
随着脚本的执行,状态行将更新:
Status: 4/4 Nodes checked, 4/4 var0 partitions, 4/4 var1 partitions
脚本成功完成后,您会看到以下内容:
Status: 4/4 Nodes checked, 4/4 var0 partitions, 4/4 var1 partitions No issues were identified. Moving files to: var_mirror_repair.2023-10-19T092522.d Bundle Location: var_mirror_repair.2023-10-19T092522.tgz
这表示任何受影响的节点都已修复,并且脚本没有问题。如果收到的输出与此示例不同,请联系 戴尔支持 并提供捆绑包位置中的输出和日志文件。
Affected Products
Isilon F800, Isilon F810, Isilon Gen6, Isilon H400, Isilon H500, Isilon H5600, Isilon H600, PowerScale Archive A300, PowerScale Archive A3000, PowerScale Hybrid H700, PowerScale Hybrid H7000Products
PowerScale F200, PowerScale F600, PowerScale F900Article Properties
Article Number: 000213248
Article Type: Solution