Data Domain: NVRAM Remote Battery Failure Alert | NVRAM-00202

Zusammenfassung: This article explains the cause and resolution of the NVRAMRemoteBatteryFailure alert (Event ID: EVT-NVRAM-00202) on Data Domain systems; This alert indicates a critical hardware fault with the NVRAM remote battery, which must be resolved before the file system can be accessed. ...

Dieser Artikel gilt für Dieser Artikel gilt nicht für Dieser Artikel ist nicht an ein bestimmtes Produkt gebunden. In diesem Artikel werden nicht alle Produktversionen aufgeführt.

Symptome

  • Event ID: EVT-NVRAM-00202
    • Alert: NVRAMRemoteBatteryFailure
    • Message: "A hardware fault was detected with an NVRAM remote battery and it may need to be replaced."
  • Filesystem is down with NVRAM alerts posted.

Example:

  • Alert ID:          EVT-NVRAM-00202
    Severity:         Critical
    Class:             hardwareFailure
    Object:            Slot=%s
    Info:                Cause=%s (see list below)
    
    Message:         A hardware fault was detected with an NVRAM remote battery and it may need to be replaced
    
    Description:     The remote battery for an NVRAM card is not in an usable state. The file system cannot be accessed until the fault is corrected or the NVRAM remote battery is replaced.

APPLIES TO

  • All Data Domain systems

Ursache

This alert is triggered when the system detects that the NVRAM remote battery is unreliable or unusable. The specific cause is detailed in the alert message (Info: Cause=). Possible causes include:

  • Unable to retrieve NVRAM battery status
  • Battery not detected
  • Battery not charging
  • Voltage levels critically high:
    • Battery 1 voltage: High Critical
    • Battery 2 voltage: High Critical
    • Battery 3 voltage: High Critical
  • Multiple battery failures detected

Lösung

      To resolve the issue:

      1. Check iDRAC (System Event Log) - SDPM/VOSS systems only 
      2. Inspect physical connections:

        • Ensure all cables between the NVRAM card, and the remote battery are securely connected.
        • Verify that the power cable from the system to the remote battery unit is properly seated.
        • If the system was previously powered off for an extended period of time, wait for the batteries to charge >=80%
      3. Replace faulty components:

        • If any cables are damaged or defective, replace them.
        • If all connections are intact and the alert persists, replace the remote backup battery unit.

      Betroffene Produkte

      PowerProtect Data Manager Appliance, Data Domain, PowerProtect Data Manager
      Artikeleigenschaften
      Artikelnummer: 000042368
      Artikeltyp: Solution
      Zuletzt geändert: 25 Aug. 2026
      Version:  7
      Antworten auf Ihre Fragen erhalten Sie von anderen Dell NutzerInnen
      Support Services
      Prüfen Sie, ob Ihr Gerät durch Support Services abgedeckt ist.