VNX Storage Processor 报告事件71678001 ESP_ERROR_SPS_REMOVED

Summary: 71678001报告备用电源或备用电池组的事件。

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Symptoms

备用电源 (SPS) 故障可能会导致写入高速缓存被禁用。

阵列报告事件代码,如下所示:

71678001 ESP_ERROR_SPS_REMOVED
71678001 BBUA has been Removed

 

Cause

该事件针对 SPS 或备用电池组组件 (BBUA),具体取决于阵列类型。
此事件也可能报告为 SP 引导顺序的一部分,如果后跟如下事件,则不是故障:

espkg            71670002 BBUA Inserted.
espkg            71670003 BBUA State Changed (TestStarted to TestCompleted).
espkg            71670003 BBUA State Changed (NotBatteryReady to BatteryReady).
espkg            71670003 BBUA State Changed (Testing to BatteryReady).

 

Resolution

应收集并检查 SPcollects,以查看 SPS 或 BBU 是否仍然出现故障。
确定是否故意卸下了 SPS/BBU,或者是否存在一些问题,例如线缆松动或组件插入不正确。

 

Affected Products

VNX5200, VNX5400, VNX5600, VNX5800, VNX7600, VNX8000
Article Properties
Article Number: 000099142
Article Type: Solution
Last Modified: 19 Sept 2025
Version:  5
Find answers to your questions from other Dell users
Support Services
Check if your device is covered by Support Services.