Connectrix Série B: Pane do kernel do switch devido ao aumento do uso de memória do daemon do Weblinker

Summary: O switch relatou um problema de MEMORY_USAGE_STATE e, após 30 minutos, o switch reinicializou devido a uma pane no kernel.

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Symptoms

De errdump saída:

2025/07/22-22:50:19 (CST), [MAPS-1003], 293324, SLOT 2 | FID 128, WARNING, CC-MA001-SANX7-1, Chassis, Condition=CHASSIS(MEMORY_USAGE_STATE/NONE==WARNING), Current Value:[MEMORY_USAGE_STATE, WARNING], RuleName=defCHASSISMEMORY_USAGE_STATE_WARN, Dashboard Category=Switch Resource, Quiet Time=1 hour.

2025/07/22-22:52:19 (CST), [MAPS-1003], 293331, SLOT 2 | FID 81, WARNING, CC-MA001-SANX7-1-81, Chassis, Condition=CHASSIS(MEMORY_USAGE_STATE/NONE==WARNING), Current Value:[MEMORY_USAGE_STATE, WARNING], RuleName=defCHASSISMEMORY_USAGE_STATE_WARN, Dashboard Category=Switch Resource, Quiet Time=1 hour.

2025/07/22-23:10:09 (CST), [EM-1033], 156895, SLOT 1 | CHASSIS, ERROR, nevccsg31swb01, CP in Slot 2 set to faulty because CP ERROR asserted.

2025/07/22-23:10:09 (CST), [EM-1047], 156896, SLOT 1 | CHASSIS, INFO, nevccsg31swb01, CP in slot 2 not faulty, CP ERROR deasserted.

2025/07/22-23:11:19 (CST), [HAM-1004], 293376, SLOT 2 | CHASSIS, INFO, nevccsg31swb01, Processor rebooted - Software Fault:Kernel Panic

Cause

O switch encontrou FOS-863077 e esse defeito causou perda de memória.

Sintoma:
O weblinker daemon O uso da memória continua aumentando durante o monitoramento do SANnav e atividades como configupload começam a falhar. 

A versão atual do switch Fabric OS 9.2.2 não tem a correção. O cliente está usando uma ferramenta de monitoramento de terceiros, que também é afetada.

Os erros do SRM-5011 mostram que o atingiu 75% do limite a partir de 21 de julho de 2025, portanto, levou um dia entre lá para o failover:

2025/07/21-18:19:43:390633 (CST), [SRM-5011], 2330474/0, SLOT 2 | FID 128, INFO, CC-MA001-SANX7-1, phy memory utilization meets or exceeds threshold of 75 percent. Current value is 76 percent., osmisc.c, line: 405, comp:osmiscd, ltime:2025/07/21-18:19:43:390406

E vemos que há muitas mensagens de falha de login do LDAP. Como todas as falhas de log-in são provenientes do HTTPS, elas estão usando o weblinker . Eles estão drenando o disponível weblinker memória até que ela se esgote completamente e faça com que um kernel se recupere.  

2025/07/22-23:06:26:207115 (CST), [SEC-1347], 2336526/293364, SLOT 2 | FID 128, INFO, CC-MA001-SANX7-1, LDAP server 10.236.91.139 reachable, but failed to validate or authorize the user account 'svc_bs_brocade_local'., ldap_config.c, line: 1237, comp:weblinker, ltime:2025/07/22-23:06:26:206934

2025/07/22-23:06:26:207828 (CST), [SEC-1193], 2336527/293365, SLOT 2 | FID 128, INFO, CC-MA001-SANX7-1, Security violation: Login failure attempt via HTTPS. IP Addr: 10.236.90.16., public.c, line: 4039, comp:weblinker, ltime:2025/07/22-23:06:26:207430

2025/07/22-23:07:12:879161 (CST), [SEC-1347], 2336528/293366, SLOT 2 | FID 128, INFO, CC-MA001-SANX7-1, LDAP server 10.236.91.139 reachable, but failed to validate or authorize the user account 'svc_bs_brocade_local'., ldap_config.c, line: 1237, comp:weblinker, ltime:2025/07/22-

Resolution

Por padrão, em sistemas Gen7, o monitor de fluxo está ativado. No entanto, se qualquer switch que executa o FOS v9.1.0 ou posterior desativar o monitoramento de fluxo, esse problema pode ser exposto. Esse problema também pode ser exposto em plataformas de 6ª geração sem a licença de visão de fluxo instalada.

Solução temporária:
Ative o monitor de fluxo:

 flow --activate sys_flow_monitor

Em sistemas de 6ª geração sem licença de visão de fluxo, faça upgrade para uma versão FOS com uma correção para esse problema.

  • FOS9.1.1d6RN-Fechado 
  • FOS9.2.0c3RN-fechado 
  • FOS9.2.1bRN-fechado 
  • FOS9.2.2aRN-Fechado 

Additional Information