Connectrix B-Series: Switch Kernel Panic på grund av att minnesanvändningen för Weblinker-daemon ökar

Summary: Switchen rapporterade ett MEMORY_USAGE_STATE problem och efter 30 minuter startades switchen om på grund av kärnpanik.

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Symptoms

Från errdump utdata:

2025/07/22-22:50:19 (CST), [MAPS-1003], 293324, SLOT 2 | FID 128, WARNING, CC-MA001-SANX7-1, Chassis, Condition=CHASSIS(MEMORY_USAGE_STATE/NONE==WARNING), Current Value:[MEMORY_USAGE_STATE, WARNING], RuleName=defCHASSISMEMORY_USAGE_STATE_WARN, Dashboard Category=Switch Resource, Quiet Time=1 hour.

2025/07/22-22:52:19 (CST), [MAPS-1003], 293331, SLOT 2 | FID 81, WARNING, CC-MA001-SANX7-1-81, Chassis, Condition=CHASSIS(MEMORY_USAGE_STATE/NONE==WARNING), Current Value:[MEMORY_USAGE_STATE, WARNING], RuleName=defCHASSISMEMORY_USAGE_STATE_WARN, Dashboard Category=Switch Resource, Quiet Time=1 hour.

2025/07/22-23:10:09 (CST), [EM-1033], 156895, SLOT 1 | CHASSIS, ERROR, nevccsg31swb01, CP in Slot 2 set to faulty because CP ERROR asserted.

2025/07/22-23:10:09 (CST), [EM-1047], 156896, SLOT 1 | CHASSIS, INFO, nevccsg31swb01, CP in slot 2 not faulty, CP ERROR deasserted.

2025/07/22-23:11:19 (CST), [HAM-1004], 293376, SLOT 2 | CHASSIS, INFO, nevccsg31swb01, Processor rebooted - Software Fault:Kernel Panic

Cause

Switchen har stött på FOS-863077 och denna defekt orsakar en minnesläcka.

Symptom:
Den weblinker daemon minnesanvändningen fortsätter att öka under SANnav-övervakning, och aktiviteter som configupload börjar misslyckas. 

Den aktuella switchversionen Fabric OS 9.2.2 har inte korrigeringen. Kunden använder ett övervakningsverktyg från tredje part, vilket också påverkas.

SRM-5011-felen visar att den nådde 75 % av gränsen från och med den 21 juli 2025, så det tog 1 dag därifrån till failover:

2025/07/21-18:19:43:390633 (CST), [SRM-5011], 2330474/0, SLOT 2 | FID 128, INFO, CC-MA001-SANX7-1, phy memory utilization meets or exceeds threshold of 75 percent. Current value is 76 percent., osmisc.c, line: 405, comp:osmiscd, ltime:2025/07/21-18:19:43:390406

Och sett finns det massor av meddelanden om att LDAP-inloggningen misslyckas. Eftersom alla inloggningsfel kommer från HTTPS använder de weblinker process. De dränerar de tillgängliga weblinker minnet tills det töms helt och orsakar en kernelpanik att återställas.  

2025/07/22-23:06:26:207115 (CST), [SEC-1347], 2336526/293364, SLOT 2 | FID 128, INFO, CC-MA001-SANX7-1, LDAP server 10.236.91.139 reachable, but failed to validate or authorize the user account 'svc_bs_brocade_local'., ldap_config.c, line: 1237, comp:weblinker, ltime:2025/07/22-23:06:26:206934

2025/07/22-23:06:26:207828 (CST), [SEC-1193], 2336527/293365, SLOT 2 | FID 128, INFO, CC-MA001-SANX7-1, Security violation: Login failure attempt via HTTPS. IP Addr: 10.236.90.16., public.c, line: 4039, comp:weblinker, ltime:2025/07/22-23:06:26:207430

2025/07/22-23:07:12:879161 (CST), [SEC-1347], 2336528/293366, SLOT 2 | FID 128, INFO, CC-MA001-SANX7-1, LDAP server 10.236.91.139 reachable, but failed to validate or authorize the user account 'svc_bs_brocade_local'., ldap_config.c, line: 1237, comp:weblinker, ltime:2025/07/22-

Resolution

Som standard är flödesövervakaren aktiverad på Gen7-system. Men om någon switch som kör FOS v9.1.0 eller senare inaktiverar flödesövervakning kan det här problemet vara exponerat. Det här problemet kan också exponeras på Gen6-plattformar utan flödesvisningslicens installerad.

Lösning:
Aktivera flödesvakten:

 flow --activate sys_flow_monitor

På Gen6-system utan flow vision-licens uppgraderar du till en FOS-version med en lösning på det här problemet.

  • FOS9.1.1d6RN-Stängd 
  • FOS9.2.0c3RN – Stängd 
  • FOS9.2.1bRN-Stängd 
  • FOS9.2.2aRN – Stängd 

Additional Information

Article Properties
Article Number: 000357440
Article Type: Solution
Last Modified: 21 Nov 2025
Version:  2
Find answers to your questions from other Dell users
Support Services
Check if your device is covered by Support Services.