Connectrix Série B: Processador DS-65xx reinicializado - Falha de software: Pane do kernel

Summary: DS-65xx comuta a pane de software

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Symptoms

O DS-65xx reinicializa inesperadamente e volta a ficar on-line sem problemas.

switchType:        109.1
switchState:        Online

SO do fabric: v7.4.1b

Tempo de atividade:
03:18:40 até 27 min, 1 usuário, média de carga: 1,09, 0,60, 0,30


errdump -a:
2016/10/10-02:51:17:200273, [HAM-1004], 3037/451, CHASSIS, INFO, DFW3-2830130-793765-B, Processador reinicializado — falha de software: kernel Panic., reboot.c, linha: 113, comp:hamd, ltime:2016/10/10-02:51:13:175020

2016/10/10-02:51:20:119799, [EM-5012], 3052/0, CHASSIS, INFO, DFW3-2830130-793765-B, iniciar emd FSS_RECOV_COLD, emfss.c, linha: 437, comp:emd, ltime:2016/10/10-02:51:20:116608

2016/10/10-02:51:20:632805, [DIAG-6004], 3055/0, CHASSIS, INFO, DFW3-2830130-793765-B, test_thread: tname porttestd Chamando fcn - PID: 1314, parameter.c, linha: 1448, comp:insmod, ltime:2016/10/10-02:51:20:630948

2016/10/10-02:51:26:438892, [EM-5012], 3056/0, CHASSI, INFO, DFW3-2830130-793765-B, fim do FSS_RECOV_ACTIVE emd (frio), emfss.c, linha: 522, comp:emd, ltime:2016/10/10-02:51:26:433133

Cause

No arquivo SUPPORTSHOW, a saída do arquivo Core é gerada.

O switch tinha um machine check/i-cache parity error com vários códigos de erro problemáticos para a memória de acesso aleatório dinâmico síncrono de taxa de data dupla (SDRAM DDR), conforme visto abaixo.

PDSHOW:

______________________********________________________
* Arquivo:/core_files/panic/core.pd20161010024344 *
* SEÇÃO:CONSOLE_LOG *
-----------------------********------------------------
============= FIM DA CABEÇA & INÍCIO DA CAUDA

=========Verificação da máquina no modo kernel.
I-Cache Parity Error

PLB41 Arbiter: SDRAM DDR: DDR0_00=0x0000190a SDRAM DDR: DDR0_01=0x01000000 SDRAM DDR: DDR0_31=0x00000000 SDRAM DDR: DDR0_32=0x00000000 SDRAM DDR: DDR0_33=0x00000000 SDRAM DDR: DDR0_34=0x00000008 SDRAM DDR: DDR0_35=0x00000000 SDRAM DDR: DDR0_36=0xffffffff SDRAM DDR: DDR0_37=0xffffffef SDRAM DDR: DDR0_38=0x00000028 SDRAM DDR: DDR0_39=0x00000000 SDRAM DDR: DDR0_40=0x00000000 SDRAM DDR: DDR0_41=0x00000000

============= FIM DA CAUDA =========================

 

Resolution

Normalmente, esse tipo de erro indica um problema de hardware.

Solução temporária: Continue monitorando o switch para uma repetição nesse problema.

Consertar: Substitua o switch.

Additional Information

O switch está executando o FOS 7.4.1b.

Affected Products

Connectrix B-Series Hardware

Products

Connectrix, Connectrix B-Series Hardware, Connectrix DS-6505B, Connectrix DS-6510B, Connectrix DS-6520B
Article Properties
Article Number: 000065300
Article Type: Solution
Last Modified: 09 Sept 2025
Version:  3
Find answers to your questions from other Dell users
Support Services
Check if your device is covered by Support Services.