VxRail: Hardware Troubleshooting Using VxRail Triage Reports VxTii

Summary: This article summarizes how to generate VxTii reports from a VxRail node.

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Symptoms

The VxTii report is run as part of the health checks performed by the VxVerify minion. Configuration data is gathered from iDRAC and ESXi, and the results are also used to generate a VxTii report for each node.
For example, the HW-Inventory is downloaded from iDRAC and crosses referenced with ESXCLI data.
This report has the data that Support is most likely to need when diagnosing problems. For example, the health, driver and firmware levels of each Network Interface Card (NIC).

VxTii reports (vxtii.txt), can be found in the VxVerify folder after VxVerify has been run. This report contains reports for each node listed sequentially.  Typically, these reports can be found in whichever folders were used to run the VxVerify tool on VxRM: 

/tmp/vxv/vxtii.txt
/var/log/mystic/vxv/vxtii.txt

The detailed set of configuration and log data that is used to generate the report is saved as 'vxtii.json', in that same folder.
On the node, the report can be found at:

/tmp/vxtii.txt

VxTii node report

After the VxVerify minion is run on a node, the vxtii.txt in the /tmp folder on that node, will only have that node's information. This could be run as part of the VxRail Manager health-checks.

 
======================================================================================================================== 
Dell VxTii report version 3.21.121 on VMware ESXi 7.0.2 build-18426014 
======================================================================================================================== 
Product          Tag    Product_Serial#   Report_Date_GMT     Inventory_Date    Hostname 
------------------------------------------------------------------------------------------------------------------------ 
VxRail_E560F   FP9P9T9   FP9P9T90000000   2022-11-22_09:17   2022-04-11_14:06   lab-12-esxi-02.any-lab.local 
------------------------------------------------------------------------------------------------------------------------ 
Dell    BIOS     iDRAC     Uptime   CPU    DIMM   PCIE   CLPD    Manufacturer     ____System_Board____ 
Gen.    Vers.    Vers.     (days) Sockets  Slots  Slots  Vers.       Name         Part#        Serial# 
------------------------------------------------------------------------------------------------------------------------ 
 14G  2.11.2    4.40.40.00   224     2      24      3    1.0.2    Dell_Inc.     0PHYDRA00   CNIVC0000P1111  
------------------------------------------------------------------------------------------------------------------------ 
RP4VM  NSX  GPU  NTP  Maint-mode      Nameservers       Unmap:Guest/Fairness   Certificate: expiry & issuer 
------------------------------------------------------------------------------------------------------------------------ 
  No    No   No  Yes   No      [172.99.0.11, 172.99.0.12]       No / Yes       1586 days   vmca@vmware.com        
======================================================================================================================== 
Recommendations For Support 
------------------------------------------------------------------------------------------------------------------------ 
No action items found   <- Action plans for some faults can be found here, such as for MEM8000
======================================================================================================================== 
CPU ...


VxTii cluster report

When the VxTii report is downloaded to VxRM, along with the health-check data, then each node's report is merged with reports from the rest of the nodes and general cluster summary data.

 
########################################################################################################################
VxTii - VxRail 8.0.311 Triage Report from VxVerify
========================================================================================================================
Dell VxTii 4.50.117 report for VxRail Manager 8.0.311 at 2025-01-18 09:16 GMT (see vxtii.txt) .
Cluster Name:    VxRail-Virtual-SAN-Cluster
Cluster_UID:     52f57a37-968e-0e20-b538-669ac2bd11b8      vSAN_Licence: Evaluation Mode         
Deployment_Type: STANDARD                                     LCM_Status: No Upgrade in progress  
vCenter_FQDN:    cluster101-vcsa.lab007.local                    EVC_Mode: intel-icelake           
========================================================================================================================
VCSA   Stretch  VCF  RP4VM  vLCM  NSX  ELM  GPU  CHM  AdvM  Satt  Health  vCenter-Build  Port  VC-API_host .
Internal   No    No    No   Yes    No   No  Yes  Yes   No   No   Healthy  8.0.3-24322831  443  vCenter_FQDN    
========================================================================================================================
VxRM-Build         VxRM_VM_UID                            MFID    VM_Latest_boot     VxRM_FQDN         .
8.0.311-28839942   564dda19-3200-3c00-7800-6d0bfeeebf00   vm-24   2025-01-18_04:36   vxrm.lab007.local 
========================================================================================================================
Plugin         |  Version (refer to KB 189279)    .
VxRM (local)      9.5.0    
hsm               7.0.410-27831806
========================================================================================================================
CHM: Cluster Health Monitoring ("No" means cluster suppressed; KB 195874).   GPU: At least one node contains a GPU (KB 191633)?
Int/Ext: Whether vCenter is Internal or External (KB 45053).         NSX: VIB for NSX present on nodes (KB 43126)?
RP4VM: RecoverPoint installed (KB 42295)?         Stretch: vSAN witness present for stretched clusters (KB 66108)?
vLCM: vSphere Lifecycle Manager enabled?       AdvM: Advanced mode enabled in LCM?  Satt: Satellite nodes present?
########################################################################################################################
VxTii report for first node etc. ...

Cause

If the VxTii report (vxtii.txt) is not automatically generated when the VxVerify script has completed, one typical cause is related to those nodes not having iDRAC (such as Quanta or virtual nodes).
A large proportion of the VxTii node report is based on iDRAC data (cross-referenced with ESXi data), and so VxTii only supports iDRAC based nodes.

VxTii abbreviations for node report

Key             VxTii heading definition
At_risk_obj     Number of Objects that would have Redundancy Reduced if the node went offline
BIOS Vers       Dell VxRail node Basic Input/Output System version
Certificate     Certificate expiry date and issuer name
CLPD            Complex programmable logic device (version found from iDRAC)
CPU sockets     Number of CPU sockets in the VxRail node
Dell Gen.       Dell PowerEdge product family Generation. E.g. 14G is the 14th Server Generation.
DIMM slots      Number of Dual Inline Memory Modules in the node
DU_objects      Number of Objects that would have Data Unavailability if the node went offline
ESA             Enterprise Storage Architecture used for vSAN
Evacuation_Data Data that would need to be moved if the vSAN node was evacuated
GPU             Graphics Processor Unit board present on the node
iDRAC Vers      Integrated Dell Remote Access Controller version
Inventory_Date  Date of the last iDRAC hardware inventory change
LACP            Link Aggregation Control Protocol in use
Lockdown        ESXi or iDRAC lockdown mode status
Maint-mode      Maintenance Mode for ESXi server
Nameservers     DNS nameservers listed in resolv.conf
NSX             VMware Network Software X found on this node
NTP             Network Time Protocol configured on this node
PCIe Slots      PCIe sockets in this model of VxRail
Prediction      Maintenance mode and evacuation outcome prediction
Product_Serial  Serial number. If not present then only the Service Tag is being used.
Rack            Node Height in Rack Units
RP4VM           RecoverPoint for Virtual Machines bundle is present
SecurBoot       Secure boot status
System_Board    Part and serial numbers if the node motherboard
Tag             Dell Service Tag for the node
TPM             Trusted Platform Module status
TPM-vers        Trusted Platform Module version
Unmap           vSAN Guest and Fairness Unmap settings
Uptime          Time in days since the last ESXi boot
VxVIB           Version of VxRail vSphere Installation Bundle on this node

Resolution

If errors occur with generating VxTii reports from VxVerify, see article: Dell VxRail: VxVerify Troubleshooting Guide
The cause of the report not being saved will probably be listed in the minion.log, such as iDRAC not responding.

Affected Products

VxRail, VxRail 460 and 470 Nodes, VxRail Appliance Series, VxRail G Series Nodes, VxRail D Series Nodes, VxRail D560, VxRail D560F, VxRail E Series Nodes, VxRail E460, VxRail E560, VxRail E560F, VxRail E560N, VxRail E660, VxRail E660F, VxRail E660N , VxRail E665, VxRail E665F, VxRail E665N, VxRail G560, VxRail G560F, VxRail P Series Nodes, VxRail P470, VxRail P570, VxRail P570F, VxRail P580N, VxRail P670F, VxRail P670N, VxRail P675F, VxRail P675N, VxRail S Series Nodes, VxRail S470, VxRail S570, VxRail S670, VxRail Software, VxRail V Series Nodes, VxRail V470, VxRail V570, VxRail V570F, VXRAIL V670F, VxRail VD-4510C, VxRail VD-4520C, VxRail VD Series Nodes, VxRail VE-660, VxRail VE-6615, VxRail VP-760, VxRail VP-7625, VxRail VS-760 ...
Article Properties
Article Number: 000066467
Article Type: Solution
Last Modified: 21 Jan 2026
Version:  7
Find answers to your questions from other Dell users
Support Services
Check if your device is covered by Support Services.