ViPR SRM:VPLEX 错误 - 执行作业 VPlexData -> DISTRIBUTED-DEVICES-CLUSTER1 时出错,并将其从队列中删除

Summary: VPLEX 收集日志时出错 - 在执行作业 VPlexData -> DISTRIBUTED-DEVICES-CLUSTER1 时出错,并已将其从队列中删除

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Symptoms



即使所有数据都填充在报告中,客户也会在其 VPLEX 收集日志中收到以下错误。

这些错误仅涉及分布式设备和见证群集。


警告 [2017-03-13 11:39:18 EDT] HttpRequestGroup:: handleResponse ():无法连接到主机 XX.XX.XX.XX (404) 请求 https://@
{cluster1.host}/vplex/distributed-storage/distributed-devices/*。Server returned the following message: 未找到
严重 [2017-03-13 11:39:18 EDT] HttpRequestRetriever::execute():无法检索任何已配置请求组上的流!
严重 [2017-03-13 11:39:18 EDT] AbstractJobExecutor::executeJobRunner():Error while executing job VPlexData -> DISTRIBUTED-DEVICES-CLUSTER1 removing it from the queue
SEVERE [2017-03-13 11:39:18 EDT] AbstractJobExecutor:: executeJobRunner():Error while executing job VPlexData -> WITNESSES-CLUSTER1 remove it from the queue
watch4net.apg.concurrent.JobExecutionException:在作业 VPlexData 中运行步骤时出现意外错误 -> WITNESSES-CLUSTER1

Cause

在发现此问题的环境中,客户具有本地 VPLEX。

“”分布式设备是分布在 2 个 VPLEX 群集之间的卷,因此它们适用于 Metro 或 Geo 设置。由于客户使用的是本地 VPLEX,因此没有这些卷类型,因此未找到它们。

此外,群集见证是一个可选组件,主要用于 Metro 或 Geo 设置。因此,如果客户没有该指纹,则预期会显示“Not found”。


Resolution

要从收集日志中删除错误,请按照以下步骤作。

导航至 opt\APG\Collecting\Stream-Collector\emc-vplex\conf 位置。

注释掉data-distdevs-clstr1.xml并在文件“data-vplex-cluster1.xml”中data-witness-cluster1.xml,如下所示:
 
  <-- 习:include href=“conf/data-distdevs-clstr1.xml” xmlns:习=“http://www.w3.org/2001/XInclude” /><
习:include href=“conf/data-witness-cluster1.xml” xmlns:习=“http://www.w3.org/2001/XInclude” />
-->

然后重新启动 VPLEX 收集服务。
<              

Affected Products

SRM
Article Properties
Article Number: 000050343
Article Type: Solution
Last Modified: 27 Oct 2025
Version:  4
Find answers to your questions from other Dell users
Support Services
Check if your device is covered by Support Services.