Symptoms

The replication link between the two DataDomain changed from microwave link to fiber link, also, enabled the encryption from the network link.

CCR clone takes 2-3 days, then fails with connection error.
NetWorker 8.2.3.5
CCR between two DD (prod and DR)
Clone scheduled within the backup

Cause

Not supported encryption on the network link

Resolution

Removed the encryption from the network link