NetWorker: wersja 9.0 Nie można sklonować zadań VMware na urządzenie CloudBoost

Summary: Klonowanie zestawów zapisów VMware vProxy do CloudBoost kończy się niepowodzeniem. Nieprawidłowe identyfikatory zestawu zapisu, brak elementów roboczych, błąd: pula z nieobsługiwanymi węzłami; Przyczyna: Węzeł w wersji 9.1. ...

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Symptoms

 

Klonowanie ustawień zapisu kopii zapasowych VMware (kopia zapasowa vProxy) na urządzeniu CloudBoost kończy się niepowodzeniem.

mm/dd/yyyy hh:mm:ss meridiem Following savesets will be skipped please make sure saveset id is valid and target pool is valid
<SSID>
mm/dd/yyyy hh:mm:ss meridiem failed to get mmd reservation with err: There are no savesets to clone, mmd reservation is skipped. .
mm/dd/yyyy hh:mm:ss meridiem Unable to update '<SSID(53>/' status. Error: Work item <SSID(53)>/ not found in running list.
mm/dd/yyyy hh:mm:ss meridiem Unable to set work item status for all failed save sets
mm/dd/yyyy hh:mm:ss meridiem No valid input savesets - check CLONE SKIPPED SAVESETS!
mm/dd/yyyy hh:mm:ss meridiem No valid backend job
mm/dd/yyyy hh:mm:ss meridiem   [ORIGINAL REQUESTED SAVESETS]
mm/dd/yyyy hh:mm:ss meridiem <SSID(53)>/;
mm/dd/yyyy hh:mm:ss meridiem   [CLONE SKIPPED SAVESETS]
mm/dd/yyyy hh:mm:ss meridiem <SSID>, <SSID>/<CLONE_ID>;
mm/dd/yyyy hh:mm:ss meridiem Action clone 'clone' with job id <JOB_ID_number> is exiting with status 'failed', exit code 1
mm/dd/yyyy hh:mm:ss meridiem NSRCLONE failed for one or more savesets.

Przejrzyj dziennik demona w czasie <mm/dd/rrrr meridiem>gg:mm:ss błędu i znajduje się komunikat:

71193 mm/dd/yyyy hh:mm:ss meridiem  0 0 0 708478784 29038 0 <NetWorker_Server_name> nsrd NSR info Protection Policy Notice: Starting action '<Action_name>' for workflow '<Policy_name>/<Workflow_name>'
165718 mm/dd/yyyy hh:mm:ss meridiem  5 5 0 109037312 29038 0 <NetWorker_Server_name> nsrd NSR critical Unable to clone save set with ID '<SSID>': The '<Pool_name>' pool includes incompatible storage nodes: Ensure that you upgrade the following storage nodes to version 9.1 or later: <CloudBoost_Storage_Node_name>.
71193 mm/dd/yyyy hh:mm:ss meridiem  0 0 0 708478784 29038 0 <NetWorker_Server_name> nsrd NSR info Error Alert: Clone operation failed with error: 'NSRCLONE failed for one or more savesets. '.
38758 mm/dd/yyyy hh:mm:ss meridiem  0 0 0 708478784 29038 0 <NetWorker_Server_name> nsrd NSR info policy notice: action clone failed
38758 mm/dd/yyyy hh:mm:ss meridiem  0 0 0 708478784 29038 0 <NetWorker_Server_name> nsrd NSR info policy notice: workflow <Workflow_name> failed
89017 mm/dd/yyyy hh:mm:ss meridiem  1 5 0 708478784 29038 0 <NetWorker_Server_name> nsrd NSR notice Scheduled resource list: NSR Protection Policy <Policy_name> exited with return code 1.
 



 

Cause

Prośba o ulepszenie. Znany problem: NW-I-404: NetWorker: Klonowanie ustawień zapisu vProxy na urządzenie CloudBoost.

Resolution

Kierownictwo produktu bada tę prośbę o ulepszenie. Wniosek jest nadal w trakcie rozpatrywania. Skontaktuj się z Centrum pomocy technicznej, aby uzyskać pomoc i podaj ten numer artykułu.

OBEJŚCIE PROBLEMU: W przypadku strefy danych NetWorker 9.0.1 lub nowszej skonfiguruj zewnętrzny węzeł pamięci masowej. Zapoznaj się z "Podręcznikiem integracji NetWorker 9.1 CloudBoost 2.1" w sekcji "NetWorker 9.1: Konfigurowanie urządzenia przy użyciu zewnętrznego węzła pamięci masowej dla CloudBoost".

Affected Products

Cloud Backup & Protection, NetWorker
Article Properties
Article Number: 000065416
Article Type: Solution
Last Modified: 04 Dec 2025
Version:  5
Find answers to your questions from other Dell users
Support Services
Check if your device is covered by Support Services.