Avamar:无法启动备份 — 重复的虚拟机目标

Summary: 本文介绍如何解决虚拟机 (VM) 映像备份失败并显示错误“重复的虚拟机目标”时的问题

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Symptoms

当 VMware 映像备份启动时,它会立即失败,并显示:

Group backup request initiating...
Failed to initiate backup.
Duplicate VM targets.
Client /vcenterLab/VirtualMachines/VM-ABC02

错误代码:31008 — 目标列表中有重复的目标。

备份失败后, /usr/local/avamar/var/var/mc/server_log/mcserver.log.0 会立即显示:

05/29-17:20:55.00639 [RMI TCP Connection(207834)-192.168.1.120#5452321] com.avamar.mc.grp.dynamic.VmRuleEngine.evaluate
FINE: Evaluating vm : (folder = /vm/LAB-PRIVATE-CLOUD/vXRAIL-MANAGEMENT/PRODUCTION,name = VM-ABC02,uuid = 502a18cf-0b7d-5d64-b211-7ef0a2a5489e)
...
...
...
05/29-17:21:00.00490 [RMI TCP Connection(207839)-192.168.1.120#5451733] com.avamar.mc.datatap.ConnectionPool.getConnection
FINE: mcdbPool: Getting 960347804 caller = com.avamar.mc.datatap.MCDataAccessObject.getSnapupHistory#6685
05/29-17:21:00.00490 [RMI TCP Connection(207839)-192.168.1.120#5451733] com.avamar.mc.datatap.MCDataAccessObject.getSnapupHistory
FINE: getSnapupHistory:select cid, gid, pid_number,last_weekly,last_monthly,last_yearly, contained_cid from snapup_history where gid='1598167177348' and cid='29e3cf78356a471bc6d30716f3459b22ef818de9' and pid_number=3016
...
...
...
05/29-17:21:00.00570 [RMI TCP Connection(207839)-192.168.1.120#5451733] com.avamar.mc.vmware.VmwareService.setupWorkorderOptions
WARNING: There are duplicate targets in the targetlist.
05/29-17:21:00.00571 [RMI TCP Connection(207839)-192.168.1.120#5451733] com.avamar.mc.cr.ClientRegistryService.doAdhocGroupBackup
WARNING: Encountered duplicate vm targets
...
...
...
05/29-17:21:00.00571 [RMI TCP Connection(207839)-192.168.1.120#5451733] com.avamar.mc.wo.JobScheduler.addWork
FINE: vlm 4260 JobScheduler:Workorder added: <WorkOrder cid="29e3cf78356a471bc6d30716f3459b22ef818de9" pid="vmimagew" wid="SCHED_OPEN_PROD_01-1717014060489" targetCid="29e3cf78356a471bc6d30716f3459b22ef818de9" snapset="ID: 1598167532577
type: backup
description: /DS-ABC-GLOBAL-VMWARE-FULL-DD-S10
ALLDATA: true
pathOverride: false
num targetList:15
Target = 3016 - [vSAN-POOL-01] d2af2a5f-00fc-c127-71e1-e4434bb2e4c0/VM-ABC02_2.vmdk recordid: null saveas: N/A canBackup: true skipped: false xmlAttributes:
Target = 3016 - [vSAN-POOL-01] d2af2a5f-00fc-c127-71e1-e4434bb2e4c0/VM-ABC02.vmdk recordid: null saveas: N/A canBackup: true skipped: false xmlAttributes:
Target = 3016 - [vSAN-POOL-01] f6d84c66-4606-6e6a-3f87-e4434bb2c000/VM-PRD0242.vmdk recordid: null saveas: N/A canBackup: true skipped: false xmlAttributes:
Target = 3016 - [vSAN-POOL-01] f6d84c66-4606-6e6a-3f87-e4434bb2c000/VM-PRD0242_1.vmdk recordid: null saveas: N/A canBackup: true skipped: false xmlAttributes:
Target = 3016 - [vSAN-POOL-01] f6d84c66-4606-6e6a-3f87-e4434bb2c000/VM-PRD0242_2.vmdk recordid: null saveas: N/A canBackup: true skipped: false xmlAttributes:
Target = 3016 - [vSAN-POOL-01] f6d84c66-4606-6e6a-3f87-e4434bb2c000/VM-PRD0242_5.vmdk recordid: null saveas: N/A canBackup: true skipped: false xmlAttributes:
Target = 3016 - [vSAN-POOL-01] f6d84c66-4606-6e6a-3f87-e4434bb2c000/VM-PRD0242_6.vmdk recordid: null saveas: N/A canBackup: true skipped: false xmlAttributes:
Target = 3016 - [vSAN-POOL-01] f6d84c66-4606-6e6a-3f87-e4434bb2c000/VM-PRD0242_4.vmdk recordid: null saveas: N/A canBackup: true skipped: false xmlAttributes:
Target = 3016 - [vSAN-POOL-01] f6d84c66-4606-6e6a-3f87-e4434bb2c000/VM-PRD0242_3.vmdk recordid: null saveas: N/A canBackup: true skipped: false xmlAttributes:
Target = 3016 - [vSAN-POOL-01] f6d84c66-4606-6e6a-3f87-e4434bb2c000/VM-PRD0242_7.vmdk recordid: null saveas: N/A canBackup: true skipped: false xmlAttributes:
Target = 3016 - [vSAN-POOL-01] f6d84c66-4606-6e6a-3f87-e4434bb2c000/VM-PRD0242_8.vmdk recordid: null saveas: N/A canBackup: true skipped: false xmlAttributes:
Target = 3016 - [vSAN-POOL-01] f6d84c66-4606-6e6a-3f87-e4434bb2c000/VM-PRD0242_9.vmdk recordid: null saveas: N/A canBackup: true skipped: false xmlAttributes:
Target = 3016 - [vSAN-POOL-01] f6d84c66-4606-6e6a-3f87-e4434bb2c000/VM-PRD0242_10.vmdk recordid: null saveas: N/A canBackup: true skipped: false xmlAttributes:
Target = 3016 - [vSAN-POOL-01] f6d84c66-4606-6e6a-3f87-e4434bb2c000/VM-PRD0242_11.vmdk recordid: null saveas: N/A canBackup: true skipped: false xmlAttributes:
Target = 3016 - [vSAN-POOL-01] f6d84c66-4606-6e6a-3f87-e4434bb2c000/VM-PRD0242_3.vmdk recordid: null saveas: N/A canBackup: true skipped: false xmlAttributes:
num includeList:0
num excludeList:0
num flagList:31

 

Cause

虚拟机 (VM) 客户端连接了不正确的磁盘。

 

Resolution

请求 VMware 管理员评估受影响的虚拟机 (VM-ABC02) 并分离不正确的磁盘 (VM-PRD0242)。

下一次备份必须正确运行。

 