Unisphere for VMAX: Error "Unisphere for VMAX Configuration Error. Installation will be aborted. SMAS Database timeout cannot be started"
Summary: During installation of host-based Unisphere, a postgres user and group is created, and this error message is seen: "Unisphere for VMAX Configuration Error. Installation will be aborted. SMAS Database timeout cannot be started" ...
This article applies to
This article does not apply to
This article is not tied to any specific product.
Not all product versions are identified in this article.
Symptoms
During installation of host-based Unisphere, a postgres user and group is created, and this error message is seen:
Unisphere for VMAX Configuration Error. Installation will be aborted.
----------------------------------------------------------------------
Please check the Unisphere for VMAX documentation to fix this configuration issue.
SMAS Database timeout cannot be started.
# service smas start
Looking for config file at /opt/emc/SMAS/jboss/domain/configuration/domain.xml.init
Info: Start DB with check
ROOT Info: Start DB without check
Message > smasdb_unix_helper.sh SMASDB is starting.
Message > smasdb_u
Message > This account is currently not available.
Cause
Check if the postgres user in /etc/passwd shows /sbin/nologin
For example:
/etc/passwd:postgres:x:504:504::/home/postgres:/sbin/nologin
/etc/group:postgres:x:504:
Resolution
To address this issue:
- Change the
/etc/passwdso that postgres user has a valid shell. For example:/bin/bash - Then uninstall and reinstall Unisphere for VMAX.
If this issue persists, then refer to knowledge article 466502 Errors often received when uninstalling or installing Unisphere from a Linux host
Affected Products
Enterprise Storage, Unisphere for VMAXArticle Properties
Article Number: 000064037
Article Type: Solution
Last Modified: 16 Sep 2025
Version: 5
Find answers to your questions from other Dell users
Support Services
Check if your device is covered by Support Services.