Baneredundans til lagringsenhet xxx degradert / gjenopprettet etter oppgradering av ESXi (HBA-driver)

Summary: VCenter-varsler: Baneredundans til lagringsenhet naa.600601600xxxxxxxxx degradert. Path vmhba2:C0:T2:L14 is down. Berørte datalagre: Ukjent. advarsel 11/28/2018 5:15:30 AM Baneredundans til lagringsenhet naa.600601600xxxxxxxxx (Datastores: Ukjent) gjenopprettet. Path vmhba2:C0:T2:L14 er aktiv igjen. info 11/28/2018 5:15:30 AM ...

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Symptoms

Etter oppgradering til ESXi 6.0 build-10474991 nedenfor begynte feil å vises. (HBA-driver 2.1.50.0-1vmw.600.3.57.5050593 og nyere)

Miljø
Vertsmodell:  ProLiant BL460c Gen8
ESXi VMware ESXi 6.0.0 build-10719132
HBA QLogic Corp 2600-serien 16 Gb fiberkanal til PCI Express HBA
HBA-driver 2.1.73.0-1OEM.600.0.0.2768847
PowerPath/VE 6.x
Unity 450F-programvare 4.3.1.1525703027

Symptomer:
Når verter kjørte VMware ESXi 6.0.0 build-6921384 (eller tidligere) Unity LUNs var ikke feil.
Etter oppgradering til ESXi 6.0 build-10474991 nedenfor begynte feil å vises. (HBA-driver 2.1.50.0-1vmw.600.3.57.5050593 og nyere)

 utdrag fra vobd.log
2018-11-28T04:15:30.337Z: [scsiCorrelator] 1176699738791us: [vob.scsi.scsipath.pathstate.dead] scsiPath vmhba2:C0:T2:L14 changed state from on
2018-11-28T04:15:30.337Z: [scsiCorrelator] 1176687116200us: [esx.problem.storage.redundancy.degraded] Baneredundans til lagringsenhet naa.600601600xxxxxx degradert. Path vmhba2:C0:T2:L14 is down. Berørte datalagre: Ukjent.
2018-11-28T04:15:30.441Z: [scsiCorrelator] 1176699843060us: [vob.scsi.scsipath.pathstate.on] scsiPath vmhba2:C0:T2:L14 changed state from dead
2018-11-28T04:15:30.442Z: [scsiCorrelator] 1176687220485us: [esx.clear.storage.redundancy.restored] Path redundancy to storage device naa.600601600xxxxxxxxx (Datastores: Ukjent) gjenopprettet. Path vmhba2:C0:T2:L14 er aktiv igjen.

 extract from vmkernel.log
2018-11-28T04:15:30.336Z cpu19:33424)Debug:PowerPath:Path vmhba2:C0:T2:L14 CMD 12 Recieved platform Status Success SCSI Status: H:0xc D:0x0 P:0x0
2018-11-28T04:15:30.336Z cpu19:33424)Debug:PowerPath:Path vmhba2:C0:T2:L14 CMD 12 Recieved platform Status Success SCSI Status: H:0xc D:0x0 P:0x0
2018-11-28T04:15:30.336Z cpu19:33424)Debug:PowerPath:Path vmhba2:C0:T2:L14 CMD 12 Recieved platform Status Success SCSI Status: H:0xc D:0x0 P:0x0
2018-11-28T04:15:30.336Z cpu19:33424)Debug:PowerPath:Path vmhba2:C0:T2:L14 CMD 12 Recieved platform Status Success SCSI Status: H:0xc D:0x0 P:0x0
2018-11-28T04:15:30.336Z cpu19:33424)PowerPath:Path vmhba2:C0:T2:L14-sonden mislyktes med statussuksess H:0x0 P:0x0 D:0x0
2018-11-28T04:15:30.336Z cpu19:33424)PowerPath:Path "vmhba2:C0:T2:L14" endres til død fra på.
2018-11-28T04:15:30.336Z cpu19:33424)Debug:PowerPath:Path vmhba2:C0:T2:L14 CMD 12 Recieved platform Status Success SCSI Status: H:0xc D:0x0 P:0x0
2018-11-28T04:15:30.441Z cpu19:33424)PowerPath:Path "vmhba2:C0:T2:L14" endres til på fra død.

Cause

Årsak (fra VMware-driverteam):
Det er en endring i ESXi 6.0 EP15 sammenlignet med ESXi 6.0 P06: Hvis feilen H:0xc rapporteres, prøver vi kommandoen på driverlaget på nytt i stedet for HBA-laget.
Dette ble gjort for å unngå full kontroll i køen.

Resolution

Installer HBA-driveren 2.1.81.0 (eller nyere) og fastvare 8.08 (eller nyere) i henhold til VMware HCL

Additional Information

Article Properties
Article Number: 000168503
Article Type: Solution
Last Modified: 10 Sept 2025
Version:  4
Find answers to your questions from other Dell users
Support Services
Check if your device is covered by Support Services.