Symptoms

Under udførelse af en opgradering af PowerFlex-klyngen til 3.6-700.103 fra gatewayen mislykkes installationen af LIA-pakken muligvis med følgende fejl i gatewaybrugergrænsefladen.

På Red Hat eller CentOS
image.png

gatewayen/opt/emc/scaleio/gatewayen/logfilerne/operations.log

ERROR operations - Could not install lia with installationId <masked>, allowReboot false and arguments  on node 192.168.25.1,192.168.20.1,192.16.15.1,192.168.10.1 due to: Command failed: Package lia-3.6-700.103 for OS rhel7 is Not Signed


/opt/emc/scaleio/gateway/logfiler/scaleio-trace.log

DEBUG c.e.s.s.i.s.i.InstallationPackageServiceImpl - getLatestPackage called for ecsComponentType lia and linuxFlavour rhel7 returned InstallationPackage{packageFile=/opt/emc/scaleio/gateway/temp/scaleio/EMC-ScaleIO-lia-3.6-700.103.el7.x86_64.rpm}
DEBUG c.e.s.s.domain.installation.Version - servicePack 7, minor String 00, buildString 00700, patch 700
DEBUG c.e.s.s.d.i.InstallationPackage - Constructed version 3.6-700.103 for an InstallationPackage EMC-ScaleIO-lia-3.6-700.103.el7.x86_64.rpm
ERROR c.e.s.s.d.i.c.UpgradeLiaCommand - Error Package lia-3.6-700.103 for OS rhel7 is Not Signed executing command .UpgradeLiaCommand (abort) : com.emc.s3g.scaleio.im.services.installation.connectors.LIANodeConnection.installPackage(LIANodeConnection.java:784)
På SLES 
Could not import RPM key on node 10.x.x.x due to gpg: WARNING: no command supplied.
error: /tmp/RPM-GPG-KEY-ScaleIO: key 1 not an armored public key.
image.pngPå gatewayen
/opt/emc/scaleio/gateway/logfiler/operations.log
ERROR operations - Could not install lia with installationId null, allowReboot false and arguments AUTH_MODE=NATIVE_AUTHENTICATION TOKEN=XXXXXXXXX  on node 10.x1.x.x due to: Command failed: Could not import RPM key on node 10.x.x1.x due to: gpg: WARNING: no command supplied.
dos2unix: converting file /tmp/RPM-GPG-KEY-ScaleIO to Unix format...
error: /tmp/RPM-GPG-KEY-ScaleIO: key 1 not an armored public key.

Cause

Det nye linjetegn mangler i filen /opt/emc/scaleio/gateway/conf/RPM-GPG-KEY-ScaleIO

Resolution

Løsning

Log på den gateway, der er blevet opgraderet til destinationsversionen.
Åbn filen placeret på /opt/emc/scaleio/gateway/conf/RPM-GPG-KEY-ScaleIO ved hjælp af vi-editoren.
Føj et nyt linjetegn til filen.
Gem filen (ved hjælp af kommandoen 'Esc' og wq!) Uden at foretage ændringer
Kontroller, at kørsel af 'rpm --import /opt/emc/scaleio/gateway/conf/RPM-GPG-KEY-ScaleIO' ikke returnerer nogen fejl.
Prøv at opgradere igen.


Reparere
Problemet er løst i PowerFlex v3.6.1, v3.5.1.9 og v4.0.1.

Affected Products

PowerFlex Software

Products

PowerFlex rack, PowerFlex Appliance
Article Properties
Article Number: 000209882
Article Type: Solution
Last Modified: 17 Jun 2025
Version:  3
Find answers to your questions from other Dell users
Support Services
Check if your device is covered by Support Services.