PowerFlex:在升級期間從閘道安裝 LIA 套裝失敗,並顯示錯誤「 命令失敗:適用於作業系統 rhel7 的套件 lia-3.6-700.103 未簽署」

Summary: 在 Powerflex Gateway 上從 v3.5 升級至 3.6.7000.103 或 v3.6.0.8 期間,lia 安裝可能會因為 RPM-GPG-KEY-ScaleIO 檔案而失敗。

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Symptoms

從閘道將 PowerFlex 叢集升級至 3.6-700.103 時,LIA 套件安裝可能會失敗,並在閘道 UI 中顯示下列錯誤。

在 Red Hat 或 CentOS
image.png

上在閘道
/opt/emc/scaleio/gateway/logs/operations.log

ERROR operations - Could not install lia with installationId <masked>, allowReboot false and arguments  on node 192.168.25.1,192.168.20.1,192.16.15.1,192.168.10.1 due to: Command failed: Package lia-3.6-700.103 for OS rhel7 is Not Signed


/opt/emc/scaleio/gateway/logs/scaleio-trace.log

DEBUG c.e.s.s.i.s.i.InstallationPackageServiceImpl - getLatestPackage called for ecsComponentType lia and linuxFlavour rhel7 returned InstallationPackage{packageFile=/opt/emc/scaleio/gateway/temp/scaleio/EMC-ScaleIO-lia-3.6-700.103.el7.x86_64.rpm}
DEBUG c.e.s.s.domain.installation.Version - servicePack 7, minor String 00, buildString 00700, patch 700
DEBUG c.e.s.s.d.i.InstallationPackage - Constructed version 3.6-700.103 for an InstallationPackage EMC-ScaleIO-lia-3.6-700.103.el7.x86_64.rpm
ERROR c.e.s.s.d.i.c.UpgradeLiaCommand - Error Package lia-3.6-700.103 for OS rhel7 is Not Signed executing command .UpgradeLiaCommand (abort) : com.emc.s3g.scaleio.im.services.installation.connectors.LIANodeConnection.installPackage(LIANodeConnection.java:784)
在 SLES 上 
Could not import RPM key on node 10.x.x.x due to gpg: WARNING: no command supplied.
error: /tmp/RPM-GPG-KEY-ScaleIO: key 1 not an armored public key.
image.png在閘道上
/opt/emc/scaleio/gateway/logs/operations.log
ERROR operations - Could not install lia with installationId null, allowReboot false and arguments AUTH_MODE=NATIVE_AUTHENTICATION TOKEN=XXXXXXXXX  on node 10.x1.x.x due to: Command failed: Could not import RPM key on node 10.x.x1.x due to: gpg: WARNING: no command supplied.
dos2unix: converting file /tmp/RPM-GPG-KEY-ScaleIO to Unix format...
error: /tmp/RPM-GPG-KEY-ScaleIO: key 1 not an armored public key.

Cause

/opt/emc/scaleio/gateway/conf/RPM-GPG-KEY-ScaleIO 檔案中遺失換行字元

Resolution

因應措施

登入已升級至目標版本的閘道。
使用 vi 編輯器開啟位於 /opt/emc/scaleio/gateway/conf/RPM-GPG-KEY-ScaleIO 的檔案。
向檔案添加換行符。
儲存檔案 (使用命令「Esc」和 wq!)在不進行任何變更
的情況下 確認執行「rpm --import /opt/emc/scaleio/gateway/conf/RPM-GPG-KEY-ScaleIO」時不會傳回任何錯誤。
重試升級作業。



此問題已在 PowerFlex v3.6.1、v3.5.1.9 和 v4.0.1 中修正。

Affected Products

PowerFlex Software

Products

PowerFlex rack, PowerFlex Appliance
Article Properties
Article Number: 000209882
Article Type: Solution
Last Modified: 17 Jun 2025
Version:  3
Find answers to your questions from other Dell users
Support Services
Check if your device is covered by Support Services.