Symptoms
从 /opt/emc/vproxy/runtime/logs/vbackupd/vbackupd-boost.log 文件中:
来自 /nsr/logs/daemon.raw:
./opt/emc/vproxy/runtime/logs/vbackupd/vbackupd-boost.log:YYYY-MM-DDTHH:MM:SSZ ERROR: [1268:7F4794001E30] ddp_connect_with_config_internal() failed, Hostname: 110DD###_T4, Err: 5037-Cannot resolve IP address from Host DD###_T4-failover for ip family 0
./opt/emc/vproxy/runtime/logs/vbackupd/vbackupd-boost.log:YYYY-MM-DDTHH:MM:SSZ ERROR: [1268:7F4794001E30] ddp_connect_with_config() failed, Hostname: DD###_T4, Err: 5037-Cannot resolve IP address from Host DD###_T4-failover for ip family 0
./opt/emc/vproxy/runtime/logs/vbackupd/vbackupd-boost.log:2023-11-01T07:08:43Z ERROR: [1268:7F4778001C80] ddp_connect_with_config_internal() failed, Hostname: DD###_T4, Err: 5037-Cannot resolve IP address from Host DD###_T4-failover for ip family 0
./opt/emc/vproxy/runtime/logs/vbackupd/vbackupd-boost.log:2023-11-01T07:08:43Z ERROR: [1268:7F4778001C80] ddp_connect_with_config() failed, Hostname: DD###_T4, Err: 5037-Cannot resolve IP address from Host DD###_T4-failover for ip family 0
---- Skipping Lines ----
./opt/emc/vproxy/runtime/logs/vbackupd/vbackupd-boost.log:2023-11-01T13:59:20Z ERROR: [1268:7F4778001C80] ddp_connect_with_config() failed, Hostname: DD###_T4, Err: 5037-Cannot resolve IP address from Host DD###_T4-failover for ip family 0
./opt/emc/vproxy/runtime/logs/vbackupd/vbackupd-boost.log:2023-11-01T14:06:29Z INFO: [1268:7F476C001C80] ddcl_nfs_open_tcp - Timed out trying to resolve the hostname: DD###_T4
./opt/emc/vproxy/runtime/logs/vbackupd/vbackupd-boost.log:2023-11-01T14:15:29Z ERROR: [1268:7F476C001C80] ddp_connect_with_config_internal() failed, Hostname: DD###_T4, Err: 5037-Cannot resolve IP address from Host DD###_T4-failover for ip family 0
./opt/emc/vproxy/runtime/logs/vbackupd/vbackupd-boost.log:2023-11-01T14:15:29Z ERROR: [1268:7F476C001C80] ddp_connect_with_config() failed, Hostname: DD###_T4, Err: 5037-Cannot resolve IP address from Host DD###_T4-failover for ip family 0
来自 /nsr/logs/daemon.raw:
71193 MM/DD/YYYY HH:MM:SS AM 0 0 0 4988 4616 0 my_networker_server nsrd NSR info Media Info: Failed to start nsrsnmd on host my_storagenode_name, error `RPC error: Failed to connect to host 'my_storagenode_name': Remote system error - No connection could be made because the target machine actively refused it.
请参阅戴尔文章 22793 NetWorker:如何使用nsr_render_log
Cause
vProxy 主机级别的名称解析问题
Resolution
在 vProxy 主机的 /etc/hosts 中手动添加 vCenter、Data Domain、NetWorker 和存储节点的 IP 地址、FQDN、短名称。
立即启动 vProxy 虚拟机备份。
立即启动 vProxy 虚拟机备份。
- 以管理员身份登录 vProxy PuTTY 会话,然后切换到 root:
sudo su - root
- 运行以下命令以创建 /etc/host 条目
# echo "IP_of_vCenter FQDN_of_vCenter ShortName_of_vCenter" >> /etc/hosts
样品:
# echo "10.10.10.10 myvcenter.abc.com myvcenter" >> /etc/hosts
# echo "IP_of_DD FQDN_of_DD ShortName_of_DD" >> /etc/hosts
# echo "IP_of_NWServer FQDN_of_NWServer ShortName_of_NWServer" >> /etc/hosts
# echo "IP_of_StorageNode FQDN_of_StorageNode ShortName_of_StorageNode" >> /etc/hostsProducts