Data Domain: DD3300: Después de reemplazar un disco, la alerta de disco persiste

Summary: Después del reemplazo de un disco, la información del disco nuevo no se actualiza en el sistema operativo Data Domain (DDOS) y la alerta permanece.

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Symptoms

Nota: DD3300 ejecuta una versión modificada del software Data Domain (DD) Virtual Edition (DDVE).
 

Dentro de Data Domain Operating System (DDOS):

1. La información del disco nuevo no se actualiza:
# disk show hardware-detailed
Disk   Slot        Manufacturer/Model   Firmware   Serial No.         Capacity   Type       State  
       (pci/idx)                                                                                   
----   ---------   ------------------   --------   --------------   ----------   --------   --------
1.1    0           ST4000NM017A         CSJ7       WJG12JG9           3.64 TiB   SAS        In Use 
1.2    1           ST4000NM017A         CSJ7       WJG18M5C           3.64 TiB   SAS        In Use 
1.3    2           ST4000NM017A         CSJ7       WJG12HZN           3.64 TiB   SAS        In Use 
1.4    3           ST4000NM017A         CSJ7       WJG18M6X           3.64 TiB   SAS        In Use 
1.5    4           ST4000NM017A         CSJ7       WJG19CGX           3.64 TiB   SAS        In Use 
1.6    5           ST4000NM017A         CSJ7       WJG17136           3.64 TiB   SAS        In Use 
1.7    6           ST4000NM017A         CSJ7       WJG19B57           3.64 TiB   SAS        In Use 
1.8    7           ST4000NM017A         CSJ7       WJG19DQ3           3.64 TiB   SAS        In Use 
1.9    8           ST4000NM017A         CSJ7       WJG17YCG           3.64 TiB   SAS        In Use 
1.10   9           ST4000NM017A         CSJ7       WJG18MK0           3.64 TiB   SAS        Unknown  <<-- Old serial number
1.11   10          (absent)             (absent)   (absent)           (absent)   (absent)   Absent 
1.12   11          (absent)             (absent)   (absent)           (absent)   (absent)   Absent 
1.13   12          MZ7LH480HBHQ0D3      HG57       S5YJNE0N810008   447.13 GiB   SATA-SSD   Non-RAID 
 
2. La alerta de disco no se borra:
Current Alerts
--------------
Id      Post Time                  Severity   Class             Object                                         Message                                                                    
-----   ------------------------   --------   ---------------   --------------------------------------------   ----------------------------------------------------------------------------
p0-24   Thu Dec 30 05:00:57 2021   CRITICAL   HardwareFailure   Enclosure=1:Disk=10:Cause=NA                   EVT-STORAGE-00031: Disk has a hardware fault and may need to be replaced.  
p0-25   Thu Dec 30 11:11:29 2021   WARNING    HardwareFailure   Enclosure=1:Disk=10:Cause=Predictive failure   EVT-STORAGE-00032: Disk has a recoverable fault but may need to be replaced.
-----   ------------------------   --------   ---------------   --------------------------------------------   ----------------------------------------------------------------------------
There are 2 active alerts.
 

Dentro de Integrated Dell Remote Access Controller (iDRAC):

El registro de eventos PUEDE mostrar el descubrimiento de la operación de reemplazo del disco. Sin embargo, el cambio de hardware no se pasa a DDVE.
 
Eventos de iDRAC:
Timestamp           Record              Message
2022-02-04 11:47:06      7              The watchdog timer expired.
2022-01-07 22:12:46      6              Drive 9 is installed in disk drive bay 1.
2022-01-07 22:08:17      5              Drive 9 in disk drive bay 1 is operating normally.
2022-01-07 22:08:16      4              Drive 9 is removed from disk drive bay 1.
2021-12-30 11:41:02      3              Fault detected on drive 9 in disk drive bay 1.
2021-07-19 19:03:25      2              The watchdog timer expired.
 

En ESXi:

La variable PTAgent que escucha el iDRAC no contiene evidencia de la comunicación rota:
2022-01-07 23:40:01,173 INFO - DellPTAgent service [version: 1.9.1-59] found healthy 
2022-01-07 23:45:01,182 INFO - DellPTAgent service [version: 1.9.1-59] found healthy 
2022-01-07 23:50:01,182 INFO - DellPTAgent service [version: 1.9.1-59] found healthy 
2022-01-07 23:55:01,193 INFO - DellPTAgent service [version: 1.9.1-59] found healthy 
2022-01-08 00:00:01,223 INFO - DellPTAgent service [version: 1.9.1-59] found healthy 
2022-01-08 00:05:01,222 INFO - DellPTAgent service [version: 1.9.1-59] found healthy 
2022-01-08 00:10:01,262 INFO - DellPTAgent service [version: 1.9.1-59] found healthy 
2022-01-08 00:15:01,253 INFO - DellPTAgent service [version: 1.9.1-59] found healthy 

Cause

La iDRAC no actualiza su información de almacenamiento.
 
La expectativa de iDRAC siempre ha sido que debe ser capaz de actualizar su inventario de almacenamiento y proporcionar la información de disco más reciente y correcta a PTAgent (en ESXi) y vulcanmon (en DDOS) cuando se quita o inserta un disco.
 
En ocasiones, la iDRAC no se actualiza y se debe restablecer manualmente.

Resolution

  1. Restablezca iDRAC en línea mediante la interfaz de usuario.
  2. Realice un restablecimiento en frío (también conocido como "drenaje de aguas residuales") según el procedimiento de restablecimiento de BMC (también conocido como drenaje de aguas residuales).
  3. Compruebe y confirme que las alertas relacionadas se hayan borrado y que el hardware del disco se muestre según lo esperado.