Symptoms
Nota: DD3300 ejecuta una versión modificada del software Data Domain (DD) Virtual Edition (DDVE).
Dentro de Data Domain Operating System (DDOS):
1. La información del disco nuevo no se actualiza:
# disk show hardware-detailed
Disk Slot Manufacturer/Model Firmware Serial No. Capacity Type State
(pci/idx)
---- --------- ------------------ -------- -------------- ---------- -------- --------
1.1 0 ST4000NM017A CSJ7 WJG12JG9 3.64 TiB SAS In Use
1.2 1 ST4000NM017A CSJ7 WJG18M5C 3.64 TiB SAS In Use
1.3 2 ST4000NM017A CSJ7 WJG12HZN 3.64 TiB SAS In Use
1.4 3 ST4000NM017A CSJ7 WJG18M6X 3.64 TiB SAS In Use
1.5 4 ST4000NM017A CSJ7 WJG19CGX 3.64 TiB SAS In Use
1.6 5 ST4000NM017A CSJ7 WJG17136 3.64 TiB SAS In Use
1.7 6 ST4000NM017A CSJ7 WJG19B57 3.64 TiB SAS In Use
1.8 7 ST4000NM017A CSJ7 WJG19DQ3 3.64 TiB SAS In Use
1.9 8 ST4000NM017A CSJ7 WJG17YCG 3.64 TiB SAS In Use
1.10 9 ST4000NM017A CSJ7 WJG18MK0 3.64 TiB SAS Unknown <<-- Old serial number
1.11 10 (absent) (absent) (absent) (absent) (absent) Absent
1.12 11 (absent) (absent) (absent) (absent) (absent) Absent
1.13 12 MZ7LH480HBHQ0D3 HG57 S5YJNE0N810008 447.13 GiB SATA-SSD Non-RAID
2. La alerta de disco no se borra:
Current Alerts
--------------
Id Post Time Severity Class Object Message
----- ------------------------ -------- --------------- -------------------------------------------- ----------------------------------------------------------------------------
p0-24 Thu Dec 30 05:00:57 2021 CRITICAL HardwareFailure Enclosure=1:Disk=10:Cause=NA EVT-STORAGE-00031: Disk has a hardware fault and may need to be replaced.
p0-25 Thu Dec 30 11:11:29 2021 WARNING HardwareFailure Enclosure=1:Disk=10:Cause=Predictive failure EVT-STORAGE-00032: Disk has a recoverable fault but may need to be replaced.
----- ------------------------ -------- --------------- -------------------------------------------- ----------------------------------------------------------------------------
There are 2 active alerts.
Dentro de Integrated Dell Remote Access Controller (iDRAC):
El registro de eventos PUEDE mostrar el descubrimiento de la operación de reemplazo del disco. Sin embargo, el cambio de hardware no se pasa a DDVE.
Eventos de iDRAC:
Timestamp Record Message
2022-02-04 11:47:06 7 The watchdog timer expired.
2022-01-07 22:12:46 6 Drive 9 is installed in disk drive bay 1.
2022-01-07 22:08:17 5 Drive 9 in disk drive bay 1 is operating normally.
2022-01-07 22:08:16 4 Drive 9 is removed from disk drive bay 1.
2021-12-30 11:41:02 3 Fault detected on drive 9 in disk drive bay 1.
2021-07-19 19:03:25 2 The watchdog timer expired.
En ESXi:
La variable
PTAgent que escucha el iDRAC no contiene evidencia de la comunicación rota:
2022-01-07 23:40:01,173 INFO - DellPTAgent service [version: 1.9.1-59] found healthy
2022-01-07 23:45:01,182 INFO - DellPTAgent service [version: 1.9.1-59] found healthy
2022-01-07 23:50:01,182 INFO - DellPTAgent service [version: 1.9.1-59] found healthy
2022-01-07 23:55:01,193 INFO - DellPTAgent service [version: 1.9.1-59] found healthy
2022-01-08 00:00:01,223 INFO - DellPTAgent service [version: 1.9.1-59] found healthy
2022-01-08 00:05:01,222 INFO - DellPTAgent service [version: 1.9.1-59] found healthy
2022-01-08 00:10:01,262 INFO - DellPTAgent service [version: 1.9.1-59] found healthy
2022-01-08 00:15:01,253 INFO - DellPTAgent service [version: 1.9.1-59] found healthy Cause
La iDRAC no actualiza su información de almacenamiento.
La expectativa de iDRAC siempre ha sido que debe ser capaz de actualizar su inventario de almacenamiento y proporcionar la información de disco más reciente y correcta a
PTAgent (en ESXi) y vulcanmon (en DDOS) cuando se quita o inserta un disco.
En ocasiones, la iDRAC no se actualiza y se debe restablecer manualmente.
Resolution
- Restablezca iDRAC en línea mediante la interfaz de usuario.
- Realice un restablecimiento en frío (también conocido como "drenaje de aguas residuales") según el procedimiento de restablecimiento de BMC (también conocido como drenaje de aguas residuales).
- Compruebe y confirme que las alertas relacionadas se hayan borrado y que el hardware del disco se muestre según lo esperado.