Data Domain: DD3300: 디스크를 교체한 후 디스크 알림이 지속됨

Summary: 디스크 교체 후 DDOS(Data Domain Operating System)에서 새 디스크 정보가 업데이트되지 않고 알림이 유지됩니다.

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Symptoms

참고: DD3300은 DD(Data Domain) DDVE(Virtual Edition) 소프트웨어의 수정된 버전을 실행합니다.
 

DDOS(Data Domain Operating System) 내에서:

1. 새 디스크 정보가 업데이트되지 않습니다.
# disk show hardware-detailed
Disk   Slot        Manufacturer/Model   Firmware   Serial No.         Capacity   Type       State  
       (pci/idx)                                                                                   
----   ---------   ------------------   --------   --------------   ----------   --------   --------
1.1    0           ST4000NM017A         CSJ7       WJG12JG9           3.64 TiB   SAS        In Use 
1.2    1           ST4000NM017A         CSJ7       WJG18M5C           3.64 TiB   SAS        In Use 
1.3    2           ST4000NM017A         CSJ7       WJG12HZN           3.64 TiB   SAS        In Use 
1.4    3           ST4000NM017A         CSJ7       WJG18M6X           3.64 TiB   SAS        In Use 
1.5    4           ST4000NM017A         CSJ7       WJG19CGX           3.64 TiB   SAS        In Use 
1.6    5           ST4000NM017A         CSJ7       WJG17136           3.64 TiB   SAS        In Use 
1.7    6           ST4000NM017A         CSJ7       WJG19B57           3.64 TiB   SAS        In Use 
1.8    7           ST4000NM017A         CSJ7       WJG19DQ3           3.64 TiB   SAS        In Use 
1.9    8           ST4000NM017A         CSJ7       WJG17YCG           3.64 TiB   SAS        In Use 
1.10   9           ST4000NM017A         CSJ7       WJG18MK0           3.64 TiB   SAS        Unknown  <<-- Old serial number
1.11   10          (absent)             (absent)   (absent)           (absent)   (absent)   Absent 
1.12   11          (absent)             (absent)   (absent)           (absent)   (absent)   Absent 
1.13   12          MZ7LH480HBHQ0D3      HG57       S5YJNE0N810008   447.13 GiB   SATA-SSD   Non-RAID 
 
2. 디스크 알림이 지워지지 않았습니다.
Current Alerts
--------------
Id      Post Time                  Severity   Class             Object                                         Message                                                                    
-----   ------------------------   --------   ---------------   --------------------------------------------   ----------------------------------------------------------------------------
p0-24   Thu Dec 30 05:00:57 2021   CRITICAL   HardwareFailure   Enclosure=1:Disk=10:Cause=NA                   EVT-STORAGE-00031: Disk has a hardware fault and may need to be replaced.  
p0-25   Thu Dec 30 11:11:29 2021   WARNING    HardwareFailure   Enclosure=1:Disk=10:Cause=Predictive failure   EVT-STORAGE-00032: Disk has a recoverable fault but may need to be replaced.
-----   ------------------------   --------   ---------------   --------------------------------------------   ----------------------------------------------------------------------------
There are 2 active alerts.
 

iDRAC(Integrated Dell Remote Access Controller) 내부:

이벤트 로그에는 디스크 교체 작업의 검색이 표시될 수 있습니다. 그러나 하드웨어 변경 사항은 DDVE로 전달되지 않습니다.
 
iDRAC 이벤트:
Timestamp           Record              Message
2022-02-04 11:47:06      7              The watchdog timer expired.
2022-01-07 22:12:46      6              Drive 9 is installed in disk drive bay 1.
2022-01-07 22:08:17      5              Drive 9 in disk drive bay 1 is operating normally.
2022-01-07 22:08:16      4              Drive 9 is removed from disk drive bay 1.
2021-12-30 11:41:02      3              Fault detected on drive 9 in disk drive bay 1.
2021-07-19 19:03:25      2              The watchdog timer expired.
 

ESXi의 경우:

PTAgent iDRAC를 수신하는 경우 통신이 끊어졌다는 증거가 없습니다.
2022-01-07 23:40:01,173 INFO - DellPTAgent service [version: 1.9.1-59] found healthy 
2022-01-07 23:45:01,182 INFO - DellPTAgent service [version: 1.9.1-59] found healthy 
2022-01-07 23:50:01,182 INFO - DellPTAgent service [version: 1.9.1-59] found healthy 
2022-01-07 23:55:01,193 INFO - DellPTAgent service [version: 1.9.1-59] found healthy 
2022-01-08 00:00:01,223 INFO - DellPTAgent service [version: 1.9.1-59] found healthy 
2022-01-08 00:05:01,222 INFO - DellPTAgent service [version: 1.9.1-59] found healthy 
2022-01-08 00:10:01,262 INFO - DellPTAgent service [version: 1.9.1-59] found healthy 
2022-01-08 00:15:01,253 INFO - DellPTAgent service [version: 1.9.1-59] found healthy 

Cause

iDRAC는 스토리지 정보를 새로 고치지 않습니다.
 
iDRAC에서는 항상 스토리지 인벤토리를 새로 고치고 올바른 최신 디스크 정보를 PTAgent (ESXi에서) 및 vulcanmon (DDOS)에서 발생한 문제를 해결합니다.
 
경우에 따라 iDRAC이 새로 고쳐지지 않으며 iDRAC를 수동으로 재설정해야 합니다.

Resolution

  1. UI를 사용하여 온라인으로 iDRAC를 재설정합니다.
  2. BMC 재설정(일명 Flea Drain) 절차에 따라 콜드 리셋(일명 "Flea Drink")을 수행합니다.
  3. 관련 알림이 지워지고 디스크 하드웨어가 예상대로 표시되는지 확인하십시오.

Affected Products

Data Domain, DD3300 Appliance
Article Properties
Article Number: 000197080
Article Type: Solution
Last Modified: 18 Jun 2026
Version:  5
Find answers to your questions from other Dell users
Support Services
Check if your device is covered by Support Services.