Data Domain: DD3300: Depois de substituir um disco, o alerta de disco persiste
Summary: Após uma substituição de disco, as informações do novo disco não são atualizadas no Data Domain Operating System (DDOS) e o alerta permanece.
This article applies to
This article does not apply to
This article is not tied to any specific product.
Not all product versions are identified in this article.
Symptoms
Nota: O DD3300 executa uma versão modificada do software Data Domain (DD) Virtual Edition (DDVE).
No Data Domain Operating System (DDOS):
1. As informações do novo disco não são atualizadas:
# disk show hardware-detailed
Disk Slot Manufacturer/Model Firmware Serial No. Capacity Type State
(pci/idx)
---- --------- ------------------ -------- -------------- ---------- -------- --------
1.1 0 ST4000NM017A CSJ7 WJG12JG9 3.64 TiB SAS In Use
1.2 1 ST4000NM017A CSJ7 WJG18M5C 3.64 TiB SAS In Use
1.3 2 ST4000NM017A CSJ7 WJG12HZN 3.64 TiB SAS In Use
1.4 3 ST4000NM017A CSJ7 WJG18M6X 3.64 TiB SAS In Use
1.5 4 ST4000NM017A CSJ7 WJG19CGX 3.64 TiB SAS In Use
1.6 5 ST4000NM017A CSJ7 WJG17136 3.64 TiB SAS In Use
1.7 6 ST4000NM017A CSJ7 WJG19B57 3.64 TiB SAS In Use
1.8 7 ST4000NM017A CSJ7 WJG19DQ3 3.64 TiB SAS In Use
1.9 8 ST4000NM017A CSJ7 WJG17YCG 3.64 TiB SAS In Use
1.10 9 ST4000NM017A CSJ7 WJG18MK0 3.64 TiB SAS Unknown <<-- Old serial number
1.11 10 (absent) (absent) (absent) (absent) (absent) Absent
1.12 11 (absent) (absent) (absent) (absent) (absent) Absent
1.13 12 MZ7LH480HBHQ0D3 HG57 S5YJNE0N810008 447.13 GiB SATA-SSD Non-RAID
2. O alerta de disco não foi removido:
Current Alerts
--------------
Id Post Time Severity Class Object Message
----- ------------------------ -------- --------------- -------------------------------------------- ----------------------------------------------------------------------------
p0-24 Thu Dec 30 05:00:57 2021 CRITICAL HardwareFailure Enclosure=1:Disk=10:Cause=NA EVT-STORAGE-00031: Disk has a hardware fault and may need to be replaced.
p0-25 Thu Dec 30 11:11:29 2021 WARNING HardwareFailure Enclosure=1:Disk=10:Cause=Predictive failure EVT-STORAGE-00032: Disk has a recoverable fault but may need to be replaced.
----- ------------------------ -------- --------------- -------------------------------------------- ----------------------------------------------------------------------------
There are 2 active alerts.
No Integrated Dell Remote Access Controller (iDRAC):
O registro de eventos PODE exibir a descoberta da operação de substituição de disco. No entanto, a alteração de hardware não é passada para o DDVE.
Eventos do iDRAC:
Timestamp Record Message
2022-02-04 11:47:06 7 The watchdog timer expired.
2022-01-07 22:12:46 6 Drive 9 is installed in disk drive bay 1.
2022-01-07 22:08:17 5 Drive 9 in disk drive bay 1 is operating normally.
2022-01-07 22:08:16 4 Drive 9 is removed from disk drive bay 1.
2021-12-30 11:41:02 3 Fault detected on drive 9 in disk drive bay 1.
2021-07-19 19:03:25 2 The watchdog timer expired.
No ESXi:
A coluna
PTAgent que escuta o iDRAC não contém evidências de comunicação quebrada:
2022-01-07 23:40:01,173 INFO - DellPTAgent service [version: 1.9.1-59] found healthy
2022-01-07 23:45:01,182 INFO - DellPTAgent service [version: 1.9.1-59] found healthy
2022-01-07 23:50:01,182 INFO - DellPTAgent service [version: 1.9.1-59] found healthy
2022-01-07 23:55:01,193 INFO - DellPTAgent service [version: 1.9.1-59] found healthy
2022-01-08 00:00:01,223 INFO - DellPTAgent service [version: 1.9.1-59] found healthy
2022-01-08 00:05:01,222 INFO - DellPTAgent service [version: 1.9.1-59] found healthy
2022-01-08 00:10:01,262 INFO - DellPTAgent service [version: 1.9.1-59] found healthy
2022-01-08 00:15:01,253 INFO - DellPTAgent service [version: 1.9.1-59] found healthy Cause
O iDRAC não atualiza suas informações de armazenamento.
A expectativa do iDRAC sempre foi que ele fosse capaz de atualizar seu inventário de armazenamento e fornecer as informações de disco mais recentes e corretas para
PTAgent (no ESXi) e vulcanmon (no DDOS) quando um disco é removido ou inserido.
Às vezes, o iDRAC não atualiza e o iDRAC deve ser redefinido manualmente.
Resolution
- Redefina o iDRAC on-line usando a interface do usuário do.
- Execute uma reinicialização a frio (também conhecida como "drenagem residual") de acordo com o procedimento BMC Reset (também conhecido como drenagem residual).
- Verifique e confirme se os alertas relacionados foram removidos e se o hardware do disco é exibido conforme esperado.
Affected Products
Data Domain, DD3300 ApplianceArticle Properties
Article Number: 000197080
Article Type: Solution
Last Modified: 18 Jun 2026
Version: 5
Find answers to your questions from other Dell users
Support Services