PowerStore: Drives Detected with Missing Encryption Keys
Summary: This article describes the PowerStore alert for "Drives detected with missing encryption keys."
Symptoms
A health check in the RxDefinitions package issues alert 0x03700103 for:
"Drives detected with missing encryption keys."
Alert raised by this RxDefinition health check:

Cause
A specific drive model may fail to have a security key properly (re)assigned to it after removal and insertion due to a delay during drive initialization. This issue has been seen when repeated drive inserts and removals while on earlier versions of the PowerStore OS. Impacted drives are usable by the system, but its security key is deleted from the internal key store before the software completes the drive initial configuration sequence.
Once this issue is encountered, the drive remains operable however, on any subsequent HA event (node reboot), the PowerStore OS detects that the drive is missing its key in the key store and the impacted drive/s may become inaccessible.
The alert is raised to inform the user that the appliance is operating with at least one drive with a missing key.
Resolution
Contact Technical Support so they can review the underlying cause of the error to determine the best course of action. Mention this KB article 000320551 to expedite processing.
Additional Information
See KB 000193518 PowerStore: Landing for Page RxDefinitions Issues for more information of the health check mechanism, the RxDefinitions package, and a complete list of RxDefinitions alerts.