Symptoms
VPLEX depolama birimi "kritik-arıza" durumunda ve temeldeki birim Dizi tarafında iyi durumda.
ll /clusters/cluster-1/storage-elements/storage-volumes/<storage-volume name> cli komutundan örnek çıktı
VPlexcli:/> ll /clusters/cluster-1/storage-elements/storage-volumes/Symm1234_0000
/clusters/cluster-1/storage-elements/storage-volumes/Symm1234_0000:
Name Value
----------------------------- ------------------------------------------------
application-consistent false
block-count 65798400
block-size 4K
capacity 251G
description -
free-chunks []
health-indications [hardware dead]
sağlık durumu kritik-hata <<--
io-status ölü
itls 0x5000144200000010/0x5000097000000000/80,
0x5000144200000010/0x5000097000000000/80,
0x5000144200000011/0x5000097000000000/80,
0x5000144200000011/0x5000097000000000/80,
0x5000144200000110/0x5000097000000000/80,
0x5000144200000110/0x5000097000000000/80,
0x5000144200000111/0x5000097000000000/80,
0x5000144200000111/0x5000097000000000/80,
0x5000144200000110/0x5000097000000000/80,
0x5000144200000110/0x5000097000000000/80, ...
(Toplam 16)
en büyük-free-chunk 0B
locality -
operational-status error
provision-type legacy
storage-array-name EMC-SYMMETRIX-XXXXXXXXX
storage-volumetype normal
system-id VPD83T3:60000097000000000000000000000000
thin-capable false
thin-rebuild true
total-free-space 0B
underlying-storage-block-size 512
use unusable
used-by [extent_Symm1234_0000_1]
vendor-specific-name EMC
Name Value
----------------------------- ------------------------------------------------
application-consistent false
block-count 65798400
block-size 4K
capacity 251G
description -
free-chunks []
health-indications [hardware dead]
sağlık durumu kritik-hata <<--
io-status ölü
itls 0x5000144200000010/0x5000097000000000/80,
0x5000144200000010/0x5000097000000000/80,
0x5000144200000011/0x5000097000000000/80,
0x5000144200000011/0x5000097000000000/80,
0x5000144200000110/0x5000097000000000/80,
0x5000144200000110/0x5000097000000000/80,
0x5000144200000111/0x5000097000000000/80,
0x5000144200000111/0x5000097000000000/80,
0x5000144200000110/0x5000097000000000/80,
0x5000144200000110/0x5000097000000000/80, ...
(Toplam 16)
en büyük-free-chunk 0B
locality -
operational-status error
provision-type legacy
storage-array-name EMC-SYMMETRIX-XXXXXXXXX
storage-volumetype normal
system-id VPD83T3:60000097000000000000000000000000
thin-capable false
thin-rebuild true
total-free-space 0B
underlying-storage-block-size 512
use unusable
used-by [extent_Symm1234_0000_1]
vendor-specific-name EMC
Depolama Birimi kritik arıza durumunda
VPlexcli:/> storage-volume summary
SUMMARY (cluster-1)
StorageVolume Name IO Status Operational Status Health State
---------------------------------------- --------- ------------------ ----------------
Symm1234_0000 dead error critical-failure <<--
Depolama Dizisi iyi durumda
VPlexcli:/>ll **/storage-arrays
/clusters/cluster-1/storage-elements/storage-arrays:
Name Connectivity Auto Ports Logical
--------------------------- Status Switch ------------------- Unit
--------------------------- ------------ ------ ------------------- Count
--------------------------- ------------ ------ ------------------- -------
EMC-SYMMETRIX-XXXXXXXXX ok true 0x5000097000000000, X
0x5000097000000000,
0x5000097000000000,
0x5000097000000000,
Dial Home'dan ölen mantıksal birimi vurgulayan örnek bir alıntı:
<Olay Verileri><![ CDATA[disk VPD83T3:60000970000000000000000000000000: disk öldü, yansıma yok
Bu depolama birimi dağıtılmış bir aygıtın parçası değilse, ana bilgisayar bu Sanal Birime erişimini kaybederek Veri Noksanlığı (DU) durumuna neden olur.
VPLEX bellenim günlükleriasc 0x27 ascq 0x7 (07/27/07) 0x7 SCSI Algılama Kodu anahtarı ile "scsi/27" olaylarının akışını gösterirve bu da ALAN AYIRMA BAŞARISIZ YAZMA KORUMASI anlamına gelir.
VPLEX ayrıca firmware.log da bir scsi/169olayı kaydeder; bu da "Bildirilen ölçülü etkin depolama biriminde alan kalmadı." anlamına gelir.
firmware.log'dan örnek scsi/27 örnekleri
<Olay Verileri><![ CDATA[disk VPD83T3:60000970000000000000000000000000: disk öldü, yansıma yok
Bu depolama birimi dağıtılmış bir aygıtın parçası değilse, ana bilgisayar bu Sanal Birime erişimini kaybederek Veri Noksanlığı (DU) durumuna neden olur.
VPLEX bellenim günlükleriasc 0x27 ascq 0x7 (07/27/07) 0x7 SCSI Algılama Kodu anahtarı ile "scsi/27" olaylarının akışını gösterirve bu da ALAN AYIRMA BAŞARISIZ YAZMA KORUMASI anlamına gelir.
VPLEX ayrıca firmware.log da bir scsi/169olayı kaydeder; bu da "Bildirilen ölçülü etkin depolama biriminde alan kalmadı." anlamına gelir.
|
128.221.252.37/cpu0/log:5988:W/"00601636f400114833-1":113877:<2 2016/07/27 22:07:22.05: scsi/169 Space allocation failed on scsi vol VPD83T3>:6000009700000000000000000000000
|
firmware.log'dan örnek scsi/27 örnekleri
128.221.253.37/cpu0/log:5988:W/"0060166fcbfe192045-1":3298782:<6>2016/11/11 06:50:57.94: scsi/27 tgt VPD83T3:60000097000000000000000000000000 cmd 0x2a status 0x2 valid 0 resp 0x70 seg 0x0 bits 0x0 key 0x7 info 0x0 alen 10 CSI 0x0 ASC 0x27 ASCQ 0x7 FRU 0x0 SKS 0x0
128.221.253.37/cpu0/log:5988:W/"0060166fcbfe192045-1":3298783:<6>2016/11/11 06:50:58.00: scsi/27 tgt VPD83T3:60000097000000000000000000000000 cmd 0x2a status 0x2 valid 0 resp 0x70 seg 0x0 bits 0x0 key 0x7 info 0x0 alen 10 CSI 0x0 ASC 0x27 ASCQ 0x7 FRU 0x0 SKS 0x0
128.221.253.37/cpu0/log:5988:W/"0060166fcbfe192045-1":3298784:<6>2016/11/11 06:50:58.16: scsi/27 tgt VPD83T3:60000097000000000000000000000000 cmd 0x2a status 0x2 valid 0 resp 0x70 seg 0x0 bits 0x0 key 0x7 info 0x0 alen 10 CSI 0x0 ASC 0x27 ASCQ 0x7 FRU 0x0 sks 0x0
128.221.253.37/cpu0/log:5988:W/"0060166fcbfe192045-1":3298785:<6>2016/11/11 06:50:58.30: scsi/27 tgt VPD83T3:60000097000000000000000000000000 cmd 0x2a status 0x2 valid 0 resp 0x70 seg 0x0 bits 0x0 key 0x7 info 0x0 alen 10 CSI 0x0 ASC 0x27 ASCQ 0x7 FRU 0x0 SKS 0x0
128.221.253.37/cpu0/log:5988:W/"0060166fcbfe192045-1":3298783:<6>2016/11/11 06:50:58.00: scsi/27 tgt VPD83T3:60000097000000000000000000000000 cmd 0x2a status 0x2 valid 0 resp 0x70 seg 0x0 bits 0x0 key 0x7 info 0x0 alen 10 CSI 0x0 ASC 0x27 ASCQ 0x7 FRU 0x0 SKS 0x0
128.221.253.37/cpu0/log:5988:W/"0060166fcbfe192045-1":3298784:<6>2016/11/11 06:50:58.16: scsi/27 tgt VPD83T3:60000097000000000000000000000000 cmd 0x2a status 0x2 valid 0 resp 0x70 seg 0x0 bits 0x0 key 0x7 info 0x0 alen 10 CSI 0x0 ASC 0x27 ASCQ 0x7 FRU 0x0 sks 0x0
128.221.253.37/cpu0/log:5988:W/"0060166fcbfe192045-1":3298785:<6>2016/11/11 06:50:58.30: scsi/27 tgt VPD83T3:60000097000000000000000000000000 cmd 0x2a status 0x2 valid 0 resp 0x70 seg 0x0 bits 0x0 key 0x7 info 0x0 alen 10 CSI 0x0 ASC 0x27 ASCQ 0x7 FRU 0x0 SKS 0x0
21 yeniden deneme gerçekleştirildikten sonra, sürekli yazma hataları nedeniyle depolama birimi ölü olarak işaretlenir.
|
128.221.253.37/cpu0/log:5988:W/"0060166fcbfe192045-1":3298797:<4>2016/11/11 06:51:01.42: amf/45 disk VPD83T3:60000097000000000000000000000000: yazma hatası: bu kullanımdaki diski ölü
olarak işaretleme128.221.253.37/cpu0/log:5988:W/"0060166fcbfe192045-1":3298798:<2>2016/11/11 06:51:01.42: amf/97 disk VPD83T3:60000097000000000000000000000000: disk öldü, yansıma yok |
|
Cause
Ölçülü etkinleştirilmiş depolama birimlerinde alan ayırma işlemi başarısız oldu. Arka uç dizisinde, VPLEX in yazma komutu verdiği adresle eşlemek için kullanılabilir depolama bloğu kalmamıştır.
Resolution
VPLEX e 27/07/07 scsi kontrol koşulunu gönderen depolama dizisi, ilgili dizi satıcısı tarafından araştırılmalıdır. Bu sorun, dizinin depolama dizisindeki "SPACE AYIRMA FAILED WRITE PROTECT" sorunu nedeniyle yazma G/Ç isteğine hizmet verememesi tarafından tetiklenir.
27/7/07 kontrol koşulundan etkilenen mantıksal birimlerin listesini almak için VPLEX Yönetim Sunucusunda aşağıdaki cli grep komutu çalıştırılabilir:
grep "scsi/27" firmware.log* | grep 'key 0x#' | grep 'asc 0x##' | grep 'ascq 0x#' | awk '{print $3, $5, $18, $19, $26,$27,$28,$29}'| sort | uniq -c | sort -nr
Örnek:
Bu, Dell olmayan bir diziyse son kullanıcıdan ilgili dizi satıcısıyla iletişime geçmesini isteyin. Depolama dizisinde mevcut olan sorunu çözmek için:
27/7/07 kontrol koşulundan etkilenen mantıksal birimlerin listesini almak için VPLEX Yönetim Sunucusunda aşağıdaki cli grep komutu çalıştırılabilir:
grep "scsi/27" firmware.log* | grep 'key 0x#' | grep 'asc 0x##' | grep 'ascq 0x#' | awk '{print $3, $5, $18, $19, $26,$27,$28,$29}'| sort | uniq -c | sort -nr
Örnek:
service@ManagementServer:/var/log/VPlex/cli>grep "scsi/27" firmware.log* | grep 'key 0x7' | grep 'asc 0x27' | grep 'ascq 0x7' | awk '{print $3, $5, $18, $19, $26,$27,$28,$29}'| sort | uniq -c | sort -nr
193474 SCSI/27 VPD83T3:60000097000000000000000000000000 ASC 0x27 ASCQ 0x7 0x7
42254 SCSI/27 VPD83T3:60000097000000000000000000000001 anahtar 0x7 ASC 0x27 ASCQ 0x7
32408 SCSI/27 VPD83T3:60000097000000000000000000000002 anahtar 0x7 ASC 0x27 ASCQ 0x7
26581 SCSI/27 VPD83T3:60000097000000000000000000000003 anahtar 0x7 ASC 0x27 ASCQ 0x7
21643 SCSI/27 VPD83T3:60000097000000000000000000000004 anahtar 0x7 ASC 0x27 ASCQ 0x7
19409 SCSI/27 VPD83T3:ASC 0x27 ASCQ 0x7
ASC 0x7 60000097000000000000000000000005 anahtar 17651 SCSI/27 VPD83T3:60000097000000000000000000000006 anahtar 0x7 ASC 0x27 ASCQ 0x7
193474 SCSI/27 VPD83T3:60000097000000000000000000000000 ASC 0x27 ASCQ 0x7 0x7
42254 SCSI/27 VPD83T3:60000097000000000000000000000001 anahtar 0x7 ASC 0x27 ASCQ 0x7
32408 SCSI/27 VPD83T3:60000097000000000000000000000002 anahtar 0x7 ASC 0x27 ASCQ 0x7
26581 SCSI/27 VPD83T3:60000097000000000000000000000003 anahtar 0x7 ASC 0x27 ASCQ 0x7
21643 SCSI/27 VPD83T3:60000097000000000000000000000004 anahtar 0x7 ASC 0x27 ASCQ 0x7
19409 SCSI/27 VPD83T3:ASC 0x27 ASCQ 0x7
ASC 0x7 60000097000000000000000000000005 anahtar 17651 SCSI/27 VPD83T3:60000097000000000000000000000006 anahtar 0x7 ASC 0x27 ASCQ 0x7
Bu, Dell olmayan bir diziyse son kullanıcıdan ilgili dizi satıcısıyla iletişime geçmesini isteyin. Depolama dizisinde mevcut olan sorunu çözmek için:
Additional Information
- Belirtilen arka uç depolama havuzu alanı boşaltıldıktan sonra, 'donanım kullanım dışı' olarak gösterilen tüm depolama birimlerinin durumunu yeniden diriltmek için VPlexcli'den 'storage-volume resurrect' komutunu çalıştırın.
- Arka Uç Dizisinin VPLEX'den UNMAP işlemini desteklemesi koşuluyla, ana bilgisayar yöneticisi ana bilgisayardan scsi UNMAP komutunu kullanarak depolamayı geri almayı deneyebilir.
- Geri kazanılan depolama yeterli değilse depolama yöneticisi, ölçülü etkinleştirilmiş depolama disk bölümlerinin kullanabileceği alanı artırmak için arka uç depolama dizisine boş blok depolama eklemelidir.
Affected Products
VPLEX for All Flash, VPLEX SeriesProducts
VPLEX Series, VPLEX VS2, VPLEX VS6Article Properties
Article Number: 000167470
Article Type: Solution
Last Modified: 28 Oct 2025
Version: 5
Find answers to your questions from other Dell users
Support Services
Check if your device is covered by Support Services.