VPLEX:由於儲存陣列的 SCSI 檢查狀況 07/27/07,儲存磁碟區處於嚴重故障狀態

Summary: 在嘗試淘汰 21 次後,VPLEX 會因底層儲存陣列的 SCSI 偵測代碼 07/27/07 而標記為磁碟失效。

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Symptoms



VPLEX 儲存磁碟區處於「嚴重故障」狀態,而基礎磁碟區在陣列端狀況良好。

CLI 命令「ll /clusters/cluster-1/storage-elements/storage-volumes/<storage-volume name>」的範例輸出
 
VPlexcli:/> ll /clusters/cluster-1/storage-elements/storage-volumes/Symm1234_0000
 
/clusters/cluster-1/storage-elements/storage-volumes/Symm1234_0000
Name Value
----------------------------- ------------------------------------------------
application-consistent 錯誤的
區塊計數 65798400
區塊大小 4K
容量 251G
說明 -
free chunks []
健全狀況指示 [硬體已失效]
健全狀況-狀態-嚴重-故障 <<--
io-狀態無效

ITLS 0x5000144200000010/0x5000097000000000/80、
0x5000144200000010/0x5000097000000000/80、
0x5000144200000011/0x5000097000000000/80、
0x5000144200000011/0x5000097000000000/80、
0x5000144200000110/0x5000097000000000/80,
                             0x5000144200000110/0x5000097000000000/80、
0x5000144200000111/0x5000097000000000/80、
0x5000144200000111/0x5000097000000000/80、
0x5000144200000110/0x5000097000000000/80、
0x5000144200000110/0x5000097000000000/80、...
                               (共 16 個)
最大可用區塊 0B
位置 -
作業狀態錯誤
隨需分配類型 舊版
儲存陣列名稱 EMC-SYMMETRIX-XXXXXXXXX
儲存磁碟區類型 正常
系統 ID VPD83T3:60000097000000000000000000000000
精簡型) 錯誤
精簡重建 真正的
可用總空間 0B
基礎儲存區塊大小 512
使用不可用
的 [extent_Symm1234_0000_1]
廠商專屬名稱 EMC


 
儲存磁碟區處於嚴重故障狀態
 
VPlexcli:/>storage-volume summary
(cluster-1)
StorageVolume Name IO Status 作業狀態 Health State
---------------------------------------- --------- ------------------ ----------------Symm1234_0000 dead error 嚴重-failure <<--
 


 
儲存陣列處於正常狀態

VPlexcli:/>ll **/storage-arrays

/clusters/cluster-1/storage-elements/storage-arrays:
名稱 連線能力 自動連接埠 邏輯
--------------------------- 狀態 切換------------------- 裝置
--------------------------- ------------ ------ ------------------- 計數
--------------------------- ------------ ------ ------------------- -------
EMC-SYMMETRIX-XXXXXXXXX確定 真0x5000097000000000,X
0x5000097000000000,0x5000097000000000,0x5000097000000000

,     

 
Dial Home 的摘錄示例,突出顯示了死亡的邏輯單元:
 
 <事件數據><![CDATA[磁碟 VPD83T3:60000970000000000000000000000000:磁碟死了,沒有鏡像存在

如果此儲存磁碟區不是分散式裝置的一部分,則主機將無法存取此虛擬磁碟區,從而導致資料不可用性 (DU) 情況。

VPLEX 韌體記錄顯示串流「SCSI/27」事件,其中 SCSI 感應代碼金鑰 0x7 asc 0x27 ascq 0x7 (07/27/07), 這表示 空間配置寫入保護失敗。

VPLEX 也會以 firmware.log 記錄 scsi/169事件,表示回報的精簡型儲存磁碟區空間不足。
 
128.221.252.37/cpu0/log:5988:W/“00601636f400114833-1”:113877:<2 2016/07/27 22:07:22.05: scsi/169 空間配置在 scsi 卷 VPD83T3:6000009700000000000000000000000>上失敗

來自 firmware.log 的 SCSI/27 例項範例
 
128.221.253.37/cpu0/log:5988:W/“0060166fcbfe192045-1”:3298782:<6>2016/11/11 06:50:57.94: scsi/27 tgt VPD83T3:60000097000000000000000000000000 cmd 0x2a 狀態0x2有效 0 resp 0x70 seg 0x0 位 0x0 key 0x7 info 0x0 alen 10 csi 0x0asc 0x27 ascq 0x7  fru 0x0 sks 0x0
128.221.253.37/cpu0/log:5988:W/“0060166fcbfe192045-1”3298783<>2016/11/11 06:50:58.00: SCSI/27 TGT VPD83T3:60000097000000000000000000000000 cmd 0x2a status 0x2 有效 0 resp 0x70 seg 0x0 位元 0x0 key 0x7 info 0x0 alen 10 csi 0x0 asc 0x27 ascq 0x7 fru 0x0 sks 0x0
128.128.128. 221.253.37/CPU0/log:5988:W/“0060166fcbfe192045-1”:3298784:<6>2016/11/11 06:50:58.16: SCSI/27 tgt VPD83T3:60000097000000000000000000000000 cmd 0x2a status 0x2 valid 0 resp 0x70 seg 0x0 bits 0x0 key 0x7 info 0x0 alen 10 csi 0x0 asc 0x27 ascq 0x7 fru0x0 sks 0x0
128.221.253.37/cpu0/log:5988:W/“0060166fcbfe192045-1”:3298785:<6>2016/11/11 06:50:58.30: SCSI/27 TGT VPD83T3:60000097000000000000000000000000 cmd 0x2a狀態0x2有效 0 resp 0x70 seg 0x0 位 0x0 key 0x7 info 0x0 alen 10 csi 0x0 asc 0x27 ascq 0x7 fru 0x0 sks 0x0


執行 21 次重試後,儲存磁碟區會因為連續寫入失敗而標記為失效。
 
128.221.253.37/cpu0/log:5988:W/“0060166fcbfe192045-1”:3298797:<4>2016/11/11 06:51:01.42: AMF/45 磁碟 VPD83T3:60000097000000000000000000000000:寫入失敗:標記此正在使用的磁碟已死
128.221.253.37/cpu0/log:5988:W/“0060166fcbfe192045-1”:3298798:<2>2016/11/11 06:51:01.42: AMF/97 磁碟 VPD83T3:60000097000000000000000000000000:磁碟死,無鏡像存在
 

Cause

精簡型儲存磁碟區的空間配置已失敗。後端陣列上沒有更多可用的儲存區塊可供對應至 VPLEX 發出寫入命令的位址。

Resolution

傳送 scsi 檢查狀況 (7/27/07) 至 VPLEX 的儲存陣列必須由個別陣列廠商進行調查。由於儲存陣列上的「空間分配失敗寫入保護」問題,陣列無法回應寫入 I/O 要求時,會觸發此問題。

可在 VPLEX 管理伺服器上執行下列 cli grep 命令,以取得受 7/27/07 檢查條件影響的邏輯單元清單:

grep “scsi/27” firmware.log* | grep 'key 0x#' | grep 'asc 0x##' | grep 'ascq 0x#' | awk '{print $3, $5, $18, $19, $26,$27,$28,$29}'| 排序 | uniq -c | sort -nr

範例
service@ManagementServer:/var/log/VPlex/cli>grep “scsi/27” firmware.log* | grep 'key 0x7' | grep 'asc 0x27' | grep 'ascq 0x7' | awk '{print $3, $5, $18, $19, $26,$27,$28,$29}'| 排序 | uniq -c | sort -nr

 193474 SCSI/27 VPD83T3:60000097000000000000000000000000 key 0x7 asc 0x27 ascq 0x7
42254 SCSI/27 VPD83T3:60000097000000000000000000000001 key 0x7 asc 0x27 ascq 0x7
32408 SCSI/27 VPD83T3:60000097000000000000000000000002 key 0x7 asc 0x27 ascq 0x7
26581 SCSI/27 VPD83T3:60000097000000000000000000000003 key 0x7 asc 0x27 ascq 0x7
21643 SCSI/27 VPD83T3:60000097000000000000000000000004 key 0x7 asc 0x27 ascq 0x7
19409 SCSI/27 VPD83T3:60000097000000000000000000000005 key 0x7 asc 0x27 ascq 0x7
17651 SCSI/27 VPD83T3:60000097000000000000000000000006 key 0x7 asc 0x27 ascq 0x7

如果這是非 Dell 陣列,請終端使用者接洽個別的陣列廠商。為了解決儲存陣列上存在的問題。


Additional Information

  • 在所述後端儲存集區空間已釋放後,請從 VPlexcli 執行命令「storage-volume resurrect」,以恢復顯示為「hardware dead」的任何儲存磁碟區狀態。
  • 如果後端陣列支援從 VPLEX 進行 UNMAP 作業,主機系統管理員可嘗試使用「scsi UNMAP」命令從主機回收儲存裝置。
  • 如果回收的儲存空間不足,儲存系統管理員必須將可用的區塊儲存新增至後端儲存陣列,以增加支援精簡型儲存磁碟區的可用空間。 

Affected Products

VPLEX for All Flash, VPLEX Series

Products

VPLEX Series, VPLEX VS2, VPLEX VS6
Article Properties
Article Number: 000167470
Article Type: Solution
Last Modified: 28 Oct 2025
Version:  5
Find answers to your questions from other Dell users
Support Services
Check if your device is covered by Support Services.