PowerFlex: Disaccoppiamento continuo SDS MTU non corrispondente

Summary: L SDS entra continuamente in uno stato disaccoppiato/disconnesso dopo essere stato aggiunto a un DVS (Distributed Virtual Switch) appena creato

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Symptoms

Un aggiornamento a vCenter non è riuscito ed è stata implementata una nuova istanza di vCenter. Le SVM esistenti sono state aggiunte al nuovo vCenter e quindi al DVS (distributed virtual switch) appena creato. Una volta completata questa operazione, un SDS ha continuato a entrare in uno stato disaccoppiato/disconnesso L SDS viene visualizzato come disconnected, Join-Pending in scli --query_all_sds prodotto:

SDS ID: b7g3bd870000000aName: SIO-ESX1 State: Disconnected, Join-Pending IP: 172.21.55.110 Port: 7072 Version: 2.0.13000

Il registro eventi MDM mostra che l SDS si disaccoppia continuamente, entra in modalità di raffreddamento e quindi si riconnette.

2017-10-09 12:35:53.155 SDS_DECOUPLED ERROR SDS: SIO-ESX1 (id b7g3bd870000000a) decoupled. 2017-10-09 12:35:53.156 SDS_IN_COOL_DOWN WARNING 
SDS: SIO-ESX1 (ID b7g3bd870000000a) will disconnect from MDM for 15 seconds failed to reconnect multiple times 2017-10-09 12:36:08.155 
SDS_RECONNECTED INFO SDS: SIO-ESX1 (ID b7g3bd870000000a) reconnected 2017-10-09 12:36:13.161 SDS_RECONNECTED INFO SDS: SIO-ESX1 
(ID b7g3bd870000000a) reconnected 2017-10-09 12:36:18.255 SDS_RECONNECTED INFO SDS: SIO-ESX1 (ID b7g3bd870000000a) reconnected 
2017-10-09 12:36:23.259 SDS_RECONNECTED INFO SDS: SIO-ESX1 (ID b7g3bd870000000a) reconnected 2017-10-09 12:36:28.255 SDS_RECONNECTED 
INFO SDS: SIO-ESX1 (ID b7g3bd870000000a) reconnected ... 2017-10-09 12:38:41.153 SDS_DECOUPLED ERROR SDS: SIO-ESX1 (id b7g3bd870000000a) 
decoupled. 2017-10-09 12:38:41.155 SDS_IN_COOL_DOWN WARNING SDS: SIO-ESX1 (ID b7g3bd870000000a) will disconnect from MDM for 15 seconds
 failed to reconnect multiple times 2017-10-09 12:38:56.159 SDS_RECONNECTED INFO SDS: SIO-ESX1 (ID b7g3bd870000000a) reconnected
 2017-10-09 12:39:01.164 SDS_RECONNECTED INFO SDS: SIO-ESX1 (ID b7g3bd870000000a) reconnected 2017-10-09 12:39:06.260 SDS_RECONNECTED 
INFO SDS: SIO-ESX1 (ID b7g3bd870000000a) reconnected 2017-10-09 12:39:11.265 SDS_RECONNECTED INFO SDS: SIO-ESX1 (ID b7g3bd870000000a) 
reconnected

I registri di traccia MDM mostrano che l SDS ha problemi di comunicazione. L SDS si connette e poi si disconnette:

09/10 12:39:11.261955 0x7f66b2a32eb0:tgtMgr_CheckMsgReturnedRC:01728: Message RC is TIMEOUT, RC is COMMUNICATION_ERROR 09/10 12:39:11.261972
 0x7f66b2a32eb0:tgtMgr_ConfigureTgt:05190: TGT_CONFIG Failed to update new TGT b9f3bd870000000a on all other TGTs RC: COMMUNICATION_ERROR
 09/10 12:39:11.261981 0x7f66b2a32eb0:tgtMgr_ProcessComplete:07188: Tgt: b7g3bd870000000a RC=COMMUNICATION_ERROR type: UP upDownState: 
DOWN processState: UP_INPROGRESS mdmTgtConGen: 51897 upPend: 1 downPend: 0 devErrPend: 0 wasDown: 1 createIP: 0 reconstructIP: 0 09/10
 12:39:11.261994 0x7f66b2a32eb0:keepalive_SetTgtFenced:00331: TGT: b7g3bd870000000a 09/10 12:39:11.262015 0x7f66b0902eb0:repExtent_IO:02976:
 Writing the repository to disk and cluster. Extent: 0 Page: 186 Offset: 761856 Size: 65536 09/10 12:39:11.263420 
0x7f66b2a32eb0:tgtMgr_InitiateProcessUnlocked:07027: Tgt: b7g3bd870000000a processType: UP upDownState: DOWN processState: IDLE 
mdmTgtConGen: 51897 upPending: 0 downPending: 0 wasDown: 1 createIP: 0 reconstructIP: 0 aboutToBeRemoved: 0 09/10 12:39:11.263472
 0x7f66b2a71eb0:tgtMgr_HandleWorkReq:04511: TgtId: b7g3bd870000000a starting Up process 09/10 12:39:11.263488 0x7f66b0926eb0:
repExtent_IO:02976: Writing the repository to disk and cluster. Extent: 0 Page: 186 Offset: 761856 Size: 65536 09/10 12:39:11.264680 
0x7f66b2a71eb0:keepalive_SetTgtListenOnly:00377: TGT: b7g3bd870000000a 09/10 12:39:11.264689 0x7f66b2a71eb0:mdmTgtMsg_SendSyncAddMdm:00505
: TGT_CONFIG TgtId: b7g3bd870000000a MdmId: 47e9330a1b66a52e mdmTgtConnectionGenNum: 51898 bForceClean: 0 bQuiesce: 0 quiesceGen: 1 
09/10 12:39:11.265081 0x7f66b2a71eb0:mosEventLog_PostInternal:00590: New event added. Message: "SDS: SIO-ESX (ID b7g3bd870000000a) 
reconnected". Additional info: "" Severity: Info 09/10 12:39:11.265091 0x7f66b2a71eb0:mdmTgtMsg_SendReconfStart:00571: TGT_CONFIG 
TgtId: b7g3bd870000000a

Cause

Uno degli uplink sul DVS (Distributed Virtual Switch) è stato impostato su 1.500 MTU, mentre i restanti componenti di rete sono stati impostati su 9.000 MTU. Ciò causava problemi di comunicazione tra SDS e MDM.

Resolution

Non si tratta di un problema di ScaleIO, ma di un problema di configurazione della rete ESXi.

Modificare l'uplink DVS (Distributed Virtual Switch) e impostare la dimensione MTU su 9000 per coerenza con tutte le impostazioni MTU di rete.
Verificare che tutti i componenti nel percorso di rete siano impostati su 9000 MTU.