VNX1 系列:SP 錯誤 (錯誤檢查代碼 0000007E 或 000000D1)

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Symptoms

 在記錄中找到的症狀:

從 /sr/143377/SPA/SPA_CKMxxxxxxxxxxx_38b007_05-21-2017_00-07-15.analysis.txt:

Stack
=====

STACK_TEXT:
fffff881'8aa77618 fffff881'8c013368:00000000'00000000 000000000'00037234 000000000'00000001 00000000'0000af28 :RPSplitter 驅動程式!
ConnectionBase_io_send fffff881'8aa77620 fffff881'8c015ef1 : fffffa80'3f438fe0 000000000'00000200 000000000'00000005 00000000'00000000 :RPSplitter 驅動程式!RPSplitterVolume::io_send+0x94
fffff881'8aa776a0 fffff881'8c016353 : fffffa80'53bb92c0 fffffa80'3f438fe0 00000000''00000034 fffff880'0a9e4e80 :RPSplitter 驅動程式!RPSplitterVolume::spl_sendToKbox+0x1a1
fffff881'8aa77740 fffff800'01ed28d1 : fffff880'0a9e5343 fffff884'00000007 00000000'00000000 fffffa80'0fc78480 :RPSplitter 驅動程式!RPSplitterVolume::spl_IoDoneCasToStorage+0x22b

==> 存取違規是在 ConnectionBase_io_send 內部完成。
這種訪問衝突也可能發生在其他函數中。例如:ConnectionBase_io_cancel (錯誤141763), ConnectionBase_uscsi_send, ...

FAULTING_IP:
RPSplitterDriver!ConnectionBase_io_send+0
fffff881'8c00d010 488b4108 mov rax,qword ptr [rcx+8]

問題:SP 錯誤 (錯誤檢查代碼 0000007E 或 000000D1)

受影響的組態 &; 設定 [複寫模式、分割器類型、壓縮、CDP/CLR/多重、FC/IP/iSCSI、原則等]:
VNX

對 RP 的影響:
單一災難。在 SP 重新開機之前,分割器將會關閉。

Cause

更多詳情:嘗試使用已釋放 RPA 的路徑時當機。這是因為指標會指向每個 IO 中儲存的路徑,而不管路徑的狀態\健全狀況如何。

Resolution

受影響的版本:
所有 CX R32 分割器。
在已修正 BZ-42061 的版本中 (例如在 R33 - BowRiver 及更新版本中

),錯誤會更容易暴露)因應措施:
處理網路問題,以盡量減少陣列與 RPA

之間的通訊問題解決方案已修正於: 
  • VNX 05.33.009.5.217
  • VNXe/Unity 4.2 SP2 (4.2.2.9632250)

Affected Products

VNX1 Series

Products

RecoverPoint, VNX1 Series, VNX2 Series
Article Properties
Article Number: 000055114
Article Type: Solution
Last Modified: 06 Nov 2025
Version:  3
Find answers to your questions from other Dell users
Support Services
Check if your device is covered by Support Services.