Vmkernel.Log에서 PowerFlex 전원 켜기 재설정 오류 스트리밍

Summary: ESXi vmkernel.log는 유닛 주의로 채워집니다. 전원 켜기 재설정 오류가 발생했습니다.

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Symptoms

시나리오
이 문제는 공유 데이터 저장소가 있는 vSphere 환경에서 정상 운영 중에 발생할 수 있습니다.

조짐
vmkernel.log의 오류 :

2020-02-26T06:37:08.094Z cpu20:2109794)WARNING: ScaleIO mapVolIO_ReportIOErrorIfNeeded:491 :[7975953082] IO-ERROR Type READ. comb: 69a3801e01c3. offsetInComb 11008920. SizeInLB 8. SDS_ID facbf26700000018. Comb Gen 1. Head Gen 12b. StartLB 19fe123
2020-02-26T06:37:08.094Z cpu20:2109794)scini: mapVolIO_ReportIOErrorIfNeeded:512: ScaleIO:Vol ID 0xecadc19600000034. Last vol TGT fault status SUCCESS(65) Reason (reservation conflict) RC (IO_FAULT_RESERVATION_CONFLICT) Retry count (0) chan (1)
2020-02-26T06:37:08.094Z cpu20:2109794)WARNING: ScaleIO blkScsi_PrintIOInfo:3333 :hCmd 0x459afefab140, OpCode 0x88, rc 53 scsiStat 24, senseCode 5, asc 0, ascq 0
2020-02-26T06:37:08.094Z cpu20:2109975)NMP: nmp_ThrottleLogForDevice:3734: last error status from device eui.36b1f928611380beecadc19600000034 repeated 1 times
2020-02-26T06:37:08.115Z cpu20:2109975)NMP: nmp_ThrottleLogForDevice:3788: Cmd 0x88 (0x459afefab140, 3042871) to dev "eui.36b1f928611380beecadc19600000034" on path "vmhba64:C0:T0:L52" Failed: H:0x0 D:0x2 P:0x0 Valid sense data: 0x6 0x29 0x2. Act:NONE
2020-02-26T06:37:08.115Z cpu20:2109975)ScsiDeviceIO: 3414: Cmd(0x459afefab140) 0x88, CmdSN 0xac from world 3042871 to dev "eui.36b1f928611380beecadc19600000034" failed H:0x0 D:0x2 P:0x0 Valid sense data: 0x6 0x29 0x2.
2020-02-26T06:37:08.115Z cpu20:2109975)ScsiCore: 1714: Power-on Reset occurred on eui.36b1f928611380beecadc19600000034

또는

2020-02-26T06:33:25.752Z cpu23:2109794)WARNING: ScaleIO mapVolIO_ReportIOErrorIfNeeded:491 :[7975730761] IO-ERROR Type READ. comb: 69a3801e0324. offsetInComb 10939880. SizeInLB 224. SDS_ID facbf26d0000001e. Comb Gen 1. Head Gen 12b. StartLB 19ba$
2020-02-26T06:33:25.752Z cpu23:2109794)scini: mapVolIO_ReportIOErrorIfNeeded:512: ScaleIO:Vol ID 0xecadc19600000034. Last vol TGT fault status SUCCESS(65) Reason (old SCSI gen without retry) RC (IO_FAULT_OLD_SCSI_GEN) Retry count (0) chan (1)
2020-02-26T06:33:25.752Z cpu23:2109794)WARNING: ScaleIO blkScsi_PrintIOInfo:3333 :hCmd 0x459af4cbe300, OpCode 0x88, rc 51 scsiStat 2, senseCode 6, asc 41, ascq 2
2020-02-26T06:33:25.752Z cpu13:2109975)ScsiDeviceIO: 3414: Cmd(0x459af4cbe300) 0x88, CmdSN 0x8f from world 3042871 to dev "eui.36b1f928611380beecadc19600000034" failed H:0x0 D:0x2 P:0x0 Valid sense data: 0x6 0x29 0x2.
2020-02-26T06:33:25.752Z cpu13:2109975)ScsiCore: 1714: Power-on Reset occurred on eui.36b1f928611380beecadc19600000034
2020-02-26T06:33:26.557Z cpu23:2109794)WARNING: ScaleIO mapVolIO_ReportIOErrorIfNeeded:491 :[7975731566] IO-ERROR Type WRITE. comb: 69a3001d80b6. offsetInComb 2749760. SizeInLB 8. SDS_ID facbf26e0000001f. Comb Gen 1. Head Gen 136. StartLB a7c07d4
2020-02-26T06:33:26.557Z cpu23:2109794)scini: mapVolIO_ReportIOErrorIfNeeded:512: ScaleIO:Vol ID 0xecadc19500000033. Last vol TGT fault status IO_FAULT_NOT_PRI(12) Reason (old SCSI gen without retry) RC (IO_FAULT_OLD_SCSI_GEN) Retry count (0) chan (1)
2020-02-26T06:33:26.557Z cpu23:2109794)WARNING: ScaleIO blkScsi_PrintIOInfo:3333 :hCmd 0x459ac1ce5bc0, OpCode 0x2a, rc 51 scsiStat 2, senseCode 6, asc 41, ascq 2
2020-02-26T06:33:26.557Z cpu13:2109975)ScsiDeviceIO: 3414: Cmd(0x459ac1ce5bc0) 0x2a, CmdSN 0xffffe001ee83fad0 from world 3042834 to dev "eui.36b1f928611380beecadc19500000033" failed H:0x0 D:0x2 P:0x0 Valid sense data: 0x6 0x29 0x2.
2020-02-26T06:33:26.557Z cpu13:2109975)ScsiCore: 1714: Power-on Reset occurred on eui.36b1f928611380beecadc19500000033
2020-02-26T06:33:26.557Z cpu13:2109975)ScsiDeviceIO: 3414: Cmd(0x459ac1d63980) 0x2a, CmdSN 0xffffe00205830340 from world 3042834 to dev "eui.36b1f928611380beecadc19500000033" failed H:0x0 D:0x2 P:0x0 Valid sense data: 0x6 0x29 0x2.

영향

IO는 영향을 받지 않으며 이러한 오류는 재시도할 수 있습니다. 최대 I/O 트래픽으로 인해 성능 저하가 발생할 수 있음

Cause

클러스터의 ESXi 호스트 중 하나인 VMFS가 잘못 구성되었습니다. HardwareAcceleratedLocking이 설정되지 않았습니다.

vSphere에서 ATS 잠금은 파일 시스템별로 또는 전역적으로 활성화할 수 있습니다. 이 경우 클러스터의 모든 호스트는 모든 VMFS 데이터 저장소에 대해 일치하는 설정(ATS만 해당)을 가지고 있지만, 한 호스트는 이 설정이 전역적으로 비활성화되어 있습니다.

[root@ESXI01:~] cat /etc/vmware/esx.conf |grep HardwareAcceleratedLocking
/adv/VMFS3/HardwareAcceleratedLocking = "0"

비교를 위해 데이터 저장소별 잠금이 올바르게 설정되었습니다(ATS).

root@ESX01:~] esxcli storage vmfs lockmode list
Volume Name                UUID                                 Type    Locking Mode  ATS Compatible  ATS Upgrade Modes  ATS Incompatibility Reason
-------------------------  -----------------------------------  ------  ------------  --------------  -----------------  ---------------------------
DAS149                     5dc98f40-5c2f58a8-f5e3-e4434b90b4ca  VMFS-6  ATS+SCSI               false  None               Device does not support ATS
PD1_00015         5df78825-074d4806-6836-e4434b90b4ca  VMFS-6  ATS                     true  No upgrade needed
PD2_00016         5df788a4-91dd451e-f732-e4434b421db8  VMFS-6  ATS                     true  No upgrade needed
PD1_00017         5df87e5f-b80e78fe-0c4d-e4434b904750  VMFS-6  ATS                     true  No upgrade needed
PD1_00018_NOVADP  5df87fad-2a18dd10-3c38-e4434b913086  VMFS-6  ATS                     true  No upgrade needed

Resolution

해결 방법

고급 설정에서 HardwareAcceleratedLocking을 활성화합니다.

영향을 받는 버전

모든 버전

수정된 버전