vmkernel.log 中串流出現 PowerFlex 開機重設錯誤

Summary: ESXi vmkernel.log中填滿了「裝置注意」:開機重設發生錯誤。

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Symptoms

劇本
在具有共用數據存儲的 vSphere 環境中正常運行期間,可能會出現此問題。

症狀
vmkernel.log中的錯誤:

2020-02-26T06:37:08.094Z cpu20:2109794)WARNING: ScaleIO mapVolIO_ReportIOErrorIfNeeded:491 :[7975953082] IO-ERROR Type READ. comb: 69a3801e01c3. offsetInComb 11008920. SizeInLB 8. SDS_ID facbf26700000018. Comb Gen 1. Head Gen 12b. StartLB 19fe123
2020-02-26T06:37:08.094Z cpu20:2109794)scini: mapVolIO_ReportIOErrorIfNeeded:512: ScaleIO:Vol ID 0xecadc19600000034. Last vol TGT fault status SUCCESS(65) Reason (reservation conflict) RC (IO_FAULT_RESERVATION_CONFLICT) Retry count (0) chan (1)
2020-02-26T06:37:08.094Z cpu20:2109794)WARNING: ScaleIO blkScsi_PrintIOInfo:3333 :hCmd 0x459afefab140, OpCode 0x88, rc 53 scsiStat 24, senseCode 5, asc 0, ascq 0
2020-02-26T06:37:08.094Z cpu20:2109975)NMP: nmp_ThrottleLogForDevice:3734: last error status from device eui.36b1f928611380beecadc19600000034 repeated 1 times
2020-02-26T06:37:08.115Z cpu20:2109975)NMP: nmp_ThrottleLogForDevice:3788: Cmd 0x88 (0x459afefab140, 3042871) to dev "eui.36b1f928611380beecadc19600000034" on path "vmhba64:C0:T0:L52" Failed: H:0x0 D:0x2 P:0x0 Valid sense data: 0x6 0x29 0x2. Act:NONE
2020-02-26T06:37:08.115Z cpu20:2109975)ScsiDeviceIO: 3414: Cmd(0x459afefab140) 0x88, CmdSN 0xac from world 3042871 to dev "eui.36b1f928611380beecadc19600000034" failed H:0x0 D:0x2 P:0x0 Valid sense data: 0x6 0x29 0x2.
2020-02-26T06:37:08.115Z cpu20:2109975)ScsiCore: 1714: Power-on Reset occurred on eui.36b1f928611380beecadc19600000034

2020-02-26T06:33:25.752Z cpu23:2109794)WARNING: ScaleIO mapVolIO_ReportIOErrorIfNeeded:491 :[7975730761] IO-ERROR Type READ. comb: 69a3801e0324. offsetInComb 10939880. SizeInLB 224. SDS_ID facbf26d0000001e. Comb Gen 1. Head Gen 12b. StartLB 19ba$
2020-02-26T06:33:25.752Z cpu23:2109794)scini: mapVolIO_ReportIOErrorIfNeeded:512: ScaleIO:Vol ID 0xecadc19600000034. Last vol TGT fault status SUCCESS(65) Reason (old SCSI gen without retry) RC (IO_FAULT_OLD_SCSI_GEN) Retry count (0) chan (1)
2020-02-26T06:33:25.752Z cpu23:2109794)WARNING: ScaleIO blkScsi_PrintIOInfo:3333 :hCmd 0x459af4cbe300, OpCode 0x88, rc 51 scsiStat 2, senseCode 6, asc 41, ascq 2
2020-02-26T06:33:25.752Z cpu13:2109975)ScsiDeviceIO: 3414: Cmd(0x459af4cbe300) 0x88, CmdSN 0x8f from world 3042871 to dev "eui.36b1f928611380beecadc19600000034" failed H:0x0 D:0x2 P:0x0 Valid sense data: 0x6 0x29 0x2.
2020-02-26T06:33:25.752Z cpu13:2109975)ScsiCore: 1714: Power-on Reset occurred on eui.36b1f928611380beecadc19600000034
2020-02-26T06:33:26.557Z cpu23:2109794)WARNING: ScaleIO mapVolIO_ReportIOErrorIfNeeded:491 :[7975731566] IO-ERROR Type WRITE. comb: 69a3001d80b6. offsetInComb 2749760. SizeInLB 8. SDS_ID facbf26e0000001f. Comb Gen 1. Head Gen 136. StartLB a7c07d4
2020-02-26T06:33:26.557Z cpu23:2109794)scini: mapVolIO_ReportIOErrorIfNeeded:512: ScaleIO:Vol ID 0xecadc19500000033. Last vol TGT fault status IO_FAULT_NOT_PRI(12) Reason (old SCSI gen without retry) RC (IO_FAULT_OLD_SCSI_GEN) Retry count (0) chan (1)
2020-02-26T06:33:26.557Z cpu23:2109794)WARNING: ScaleIO blkScsi_PrintIOInfo:3333 :hCmd 0x459ac1ce5bc0, OpCode 0x2a, rc 51 scsiStat 2, senseCode 6, asc 41, ascq 2
2020-02-26T06:33:26.557Z cpu13:2109975)ScsiDeviceIO: 3414: Cmd(0x459ac1ce5bc0) 0x2a, CmdSN 0xffffe001ee83fad0 from world 3042834 to dev "eui.36b1f928611380beecadc19500000033" failed H:0x0 D:0x2 P:0x0 Valid sense data: 0x6 0x29 0x2.
2020-02-26T06:33:26.557Z cpu13:2109975)ScsiCore: 1714: Power-on Reset occurred on eui.36b1f928611380beecadc19500000033
2020-02-26T06:33:26.557Z cpu13:2109975)ScsiDeviceIO: 3414: Cmd(0x459ac1d63980) 0x2a, CmdSN 0xffffe00205830340 from world 3042834 to dev "eui.36b1f928611380beecadc19500000033" failed H:0x0 D:0x2 P:0x0 Valid sense data: 0x6 0x29 0x2.

影響

IO 不受影響,這些錯誤是可重試的。尖峰 I/O 流量可能會導致效能下降

Cause

叢集中的其中一個 ESXi 主機設定錯誤 - VMFS。未設定 HardwareAcceleratedLocked。

在 vSphere 中,可以為每個檔案系統或全域啟用 ATS 鎖定。在這種情況下,叢集中的所有主機都有其所有 VMFS 資料存放區的相符設定 (僅限 ATS),但有一個主機已全域停用:

[root@ESXI01:~] cat /etc/vmware/esx.conf |grep HardwareAcceleratedLocking
/adv/VMFS3/HardwareAcceleratedLocking = "0"

為了進行比較,已正確設定每個資料存放區的鎖定 (ATS):

root@ESX01:~] esxcli storage vmfs lockmode list
Volume Name                UUID                                 Type    Locking Mode  ATS Compatible  ATS Upgrade Modes  ATS Incompatibility Reason
-------------------------  -----------------------------------  ------  ------------  --------------  -----------------  ---------------------------
DAS149                     5dc98f40-5c2f58a8-f5e3-e4434b90b4ca  VMFS-6  ATS+SCSI               false  None               Device does not support ATS
PD1_00015         5df78825-074d4806-6836-e4434b90b4ca  VMFS-6  ATS                     true  No upgrade needed
PD2_00016         5df788a4-91dd451e-f732-e4434b421db8  VMFS-6  ATS                     true  No upgrade needed
PD1_00017         5df87e5f-b80e78fe-0c4d-e4434b904750  VMFS-6  ATS                     true  No upgrade needed
PD1_00018_NOVADP  5df87fad-2a18dd10-3c38-e4434b913086  VMFS-6  ATS                     true  No upgrade needed

Resolution

因應措施

在進階設定中啟用硬體加速鎖定。

受影響的版本

所有版本

已修正問題的版本

不適用 - 非 VxFlex 作業系統問題

Affected Products

PowerFlex rack, VxFlex Product Family
Article Properties
Article Number: 000203036
Article Type: Solution
Last Modified: 18 Mar 2025
Version:  4
Find answers to your questions from other Dell users
Support Services
Check if your device is covered by Support Services.