Vmkernel.Log에서 PowerFlex 전원 켜기 재설정 오류 스트리밍
Summary: ESXi vmkernel.log는 유닛 주의로 채워집니다. 전원 켜기 재설정 오류가 발생했습니다.
This article applies to
This article does not apply to
This article is not tied to any specific product.
Not all product versions are identified in this article.
Symptoms
시나리오
이 문제는 공유 데이터 저장소가 있는 vSphere 환경에서 정상 운영 중에 발생할 수 있습니다.
조짐
vmkernel.log의 오류 :
2020-02-26T06:37:08.094Z cpu20:2109794)WARNING: ScaleIO mapVolIO_ReportIOErrorIfNeeded:491 :[7975953082] IO-ERROR Type READ. comb: 69a3801e01c3. offsetInComb 11008920. SizeInLB 8. SDS_ID facbf26700000018. Comb Gen 1. Head Gen 12b. StartLB 19fe123 2020-02-26T06:37:08.094Z cpu20:2109794)scini: mapVolIO_ReportIOErrorIfNeeded:512: ScaleIO:Vol ID 0xecadc19600000034. Last vol TGT fault status SUCCESS(65) Reason (reservation conflict) RC (IO_FAULT_RESERVATION_CONFLICT) Retry count (0) chan (1) 2020-02-26T06:37:08.094Z cpu20:2109794)WARNING: ScaleIO blkScsi_PrintIOInfo:3333 :hCmd 0x459afefab140, OpCode 0x88, rc 53 scsiStat 24, senseCode 5, asc 0, ascq 0 2020-02-26T06:37:08.094Z cpu20:2109975)NMP: nmp_ThrottleLogForDevice:3734: last error status from device eui.36b1f928611380beecadc19600000034 repeated 1 times 2020-02-26T06:37:08.115Z cpu20:2109975)NMP: nmp_ThrottleLogForDevice:3788: Cmd 0x88 (0x459afefab140, 3042871) to dev "eui.36b1f928611380beecadc19600000034" on path "vmhba64:C0:T0:L52" Failed: H:0x0 D:0x2 P:0x0 Valid sense data: 0x6 0x29 0x2. Act:NONE 2020-02-26T06:37:08.115Z cpu20:2109975)ScsiDeviceIO: 3414: Cmd(0x459afefab140) 0x88, CmdSN 0xac from world 3042871 to dev "eui.36b1f928611380beecadc19600000034" failed H:0x0 D:0x2 P:0x0 Valid sense data: 0x6 0x29 0x2. 2020-02-26T06:37:08.115Z cpu20:2109975)ScsiCore: 1714: Power-on Reset occurred on eui.36b1f928611380beecadc19600000034
또는
2020-02-26T06:33:25.752Z cpu23:2109794)WARNING: ScaleIO mapVolIO_ReportIOErrorIfNeeded:491 :[7975730761] IO-ERROR Type READ. comb: 69a3801e0324. offsetInComb 10939880. SizeInLB 224. SDS_ID facbf26d0000001e. Comb Gen 1. Head Gen 12b. StartLB 19ba$ 2020-02-26T06:33:25.752Z cpu23:2109794)scini: mapVolIO_ReportIOErrorIfNeeded:512: ScaleIO:Vol ID 0xecadc19600000034. Last vol TGT fault status SUCCESS(65) Reason (old SCSI gen without retry) RC (IO_FAULT_OLD_SCSI_GEN) Retry count (0) chan (1) 2020-02-26T06:33:25.752Z cpu23:2109794)WARNING: ScaleIO blkScsi_PrintIOInfo:3333 :hCmd 0x459af4cbe300, OpCode 0x88, rc 51 scsiStat 2, senseCode 6, asc 41, ascq 2 2020-02-26T06:33:25.752Z cpu13:2109975)ScsiDeviceIO: 3414: Cmd(0x459af4cbe300) 0x88, CmdSN 0x8f from world 3042871 to dev "eui.36b1f928611380beecadc19600000034" failed H:0x0 D:0x2 P:0x0 Valid sense data: 0x6 0x29 0x2. 2020-02-26T06:33:25.752Z cpu13:2109975)ScsiCore: 1714: Power-on Reset occurred on eui.36b1f928611380beecadc19600000034 2020-02-26T06:33:26.557Z cpu23:2109794)WARNING: ScaleIO mapVolIO_ReportIOErrorIfNeeded:491 :[7975731566] IO-ERROR Type WRITE. comb: 69a3001d80b6. offsetInComb 2749760. SizeInLB 8. SDS_ID facbf26e0000001f. Comb Gen 1. Head Gen 136. StartLB a7c07d4 2020-02-26T06:33:26.557Z cpu23:2109794)scini: mapVolIO_ReportIOErrorIfNeeded:512: ScaleIO:Vol ID 0xecadc19500000033. Last vol TGT fault status IO_FAULT_NOT_PRI(12) Reason (old SCSI gen without retry) RC (IO_FAULT_OLD_SCSI_GEN) Retry count (0) chan (1) 2020-02-26T06:33:26.557Z cpu23:2109794)WARNING: ScaleIO blkScsi_PrintIOInfo:3333 :hCmd 0x459ac1ce5bc0, OpCode 0x2a, rc 51 scsiStat 2, senseCode 6, asc 41, ascq 2 2020-02-26T06:33:26.557Z cpu13:2109975)ScsiDeviceIO: 3414: Cmd(0x459ac1ce5bc0) 0x2a, CmdSN 0xffffe001ee83fad0 from world 3042834 to dev "eui.36b1f928611380beecadc19500000033" failed H:0x0 D:0x2 P:0x0 Valid sense data: 0x6 0x29 0x2. 2020-02-26T06:33:26.557Z cpu13:2109975)ScsiCore: 1714: Power-on Reset occurred on eui.36b1f928611380beecadc19500000033 2020-02-26T06:33:26.557Z cpu13:2109975)ScsiDeviceIO: 3414: Cmd(0x459ac1d63980) 0x2a, CmdSN 0xffffe00205830340 from world 3042834 to dev "eui.36b1f928611380beecadc19500000033" failed H:0x0 D:0x2 P:0x0 Valid sense data: 0x6 0x29 0x2.
영향
IO는 영향을 받지 않으며 이러한 오류는 재시도할 수 있습니다. 최대 I/O 트래픽으로 인해 성능 저하가 발생할 수 있음
Cause
클러스터의 ESXi 호스트 중 하나인 VMFS가 잘못 구성되었습니다. HardwareAcceleratedLocking이 설정되지 않았습니다.
vSphere에서 ATS 잠금은 파일 시스템별로 또는 전역적으로 활성화할 수 있습니다. 이 경우 클러스터의 모든 호스트는 모든 VMFS 데이터 저장소에 대해 일치하는 설정(ATS만 해당)을 가지고 있지만, 한 호스트는 이 설정이 전역적으로 비활성화되어 있습니다.
[root@ESXI01:~] cat /etc/vmware/esx.conf |grep HardwareAcceleratedLocking /adv/VMFS3/HardwareAcceleratedLocking = "0"
비교를 위해 데이터 저장소별 잠금이 올바르게 설정되었습니다(ATS).
root@ESX01:~] esxcli storage vmfs lockmode list Volume Name UUID Type Locking Mode ATS Compatible ATS Upgrade Modes ATS Incompatibility Reason ------------------------- ----------------------------------- ------ ------------ -------------- ----------------- --------------------------- DAS149 5dc98f40-5c2f58a8-f5e3-e4434b90b4ca VMFS-6 ATS+SCSI false None Device does not support ATS PD1_00015 5df78825-074d4806-6836-e4434b90b4ca VMFS-6 ATS true No upgrade needed PD2_00016 5df788a4-91dd451e-f732-e4434b421db8 VMFS-6 ATS true No upgrade needed PD1_00017 5df87e5f-b80e78fe-0c4d-e4434b904750 VMFS-6 ATS true No upgrade needed PD1_00018_NOVADP 5df87fad-2a18dd10-3c38-e4434b913086 VMFS-6 ATS true No upgrade needed
Resolution
해결 방법
고급 설정에서 HardwareAcceleratedLocking을 활성화합니다.
영향을 받는 버전
모든 버전
수정된 버전
해당 없음 - VxFlex OS 문제가 아님