PowerFlex 开机重置错误在 Vmkernel 中流式传输。日志
Summary: ESXi vmkernel.log填充了“Unit Attention:发生开机重置错误。
This article applies to
This article does not apply to
This article is not tied to any specific product.
Not all product versions are identified in this article.
Symptoms
场景
在具有共享数据存储区的 vSphere 环境中执行正常作期间,可能会出现此问题。
症状
vmkernel.log中的错误:
2020-02-26T06:37:08.094Z cpu20:2109794)WARNING: ScaleIO mapVolIO_ReportIOErrorIfNeeded:491 :[7975953082] IO-ERROR Type READ. comb: 69a3801e01c3. offsetInComb 11008920. SizeInLB 8. SDS_ID facbf26700000018. Comb Gen 1. Head Gen 12b. StartLB 19fe123 2020-02-26T06:37:08.094Z cpu20:2109794)scini: mapVolIO_ReportIOErrorIfNeeded:512: ScaleIO:Vol ID 0xecadc19600000034. Last vol TGT fault status SUCCESS(65) Reason (reservation conflict) RC (IO_FAULT_RESERVATION_CONFLICT) Retry count (0) chan (1) 2020-02-26T06:37:08.094Z cpu20:2109794)WARNING: ScaleIO blkScsi_PrintIOInfo:3333 :hCmd 0x459afefab140, OpCode 0x88, rc 53 scsiStat 24, senseCode 5, asc 0, ascq 0 2020-02-26T06:37:08.094Z cpu20:2109975)NMP: nmp_ThrottleLogForDevice:3734: last error status from device eui.36b1f928611380beecadc19600000034 repeated 1 times 2020-02-26T06:37:08.115Z cpu20:2109975)NMP: nmp_ThrottleLogForDevice:3788: Cmd 0x88 (0x459afefab140, 3042871) to dev "eui.36b1f928611380beecadc19600000034" on path "vmhba64:C0:T0:L52" Failed: H:0x0 D:0x2 P:0x0 Valid sense data: 0x6 0x29 0x2. Act:NONE 2020-02-26T06:37:08.115Z cpu20:2109975)ScsiDeviceIO: 3414: Cmd(0x459afefab140) 0x88, CmdSN 0xac from world 3042871 to dev "eui.36b1f928611380beecadc19600000034" failed H:0x0 D:0x2 P:0x0 Valid sense data: 0x6 0x29 0x2. 2020-02-26T06:37:08.115Z cpu20:2109975)ScsiCore: 1714: Power-on Reset occurred on eui.36b1f928611380beecadc19600000034
或者
2020-02-26T06:33:25.752Z cpu23:2109794)WARNING: ScaleIO mapVolIO_ReportIOErrorIfNeeded:491 :[7975730761] IO-ERROR Type READ. comb: 69a3801e0324. offsetInComb 10939880. SizeInLB 224. SDS_ID facbf26d0000001e. Comb Gen 1. Head Gen 12b. StartLB 19ba$ 2020-02-26T06:33:25.752Z cpu23:2109794)scini: mapVolIO_ReportIOErrorIfNeeded:512: ScaleIO:Vol ID 0xecadc19600000034. Last vol TGT fault status SUCCESS(65) Reason (old SCSI gen without retry) RC (IO_FAULT_OLD_SCSI_GEN) Retry count (0) chan (1) 2020-02-26T06:33:25.752Z cpu23:2109794)WARNING: ScaleIO blkScsi_PrintIOInfo:3333 :hCmd 0x459af4cbe300, OpCode 0x88, rc 51 scsiStat 2, senseCode 6, asc 41, ascq 2 2020-02-26T06:33:25.752Z cpu13:2109975)ScsiDeviceIO: 3414: Cmd(0x459af4cbe300) 0x88, CmdSN 0x8f from world 3042871 to dev "eui.36b1f928611380beecadc19600000034" failed H:0x0 D:0x2 P:0x0 Valid sense data: 0x6 0x29 0x2. 2020-02-26T06:33:25.752Z cpu13:2109975)ScsiCore: 1714: Power-on Reset occurred on eui.36b1f928611380beecadc19600000034 2020-02-26T06:33:26.557Z cpu23:2109794)WARNING: ScaleIO mapVolIO_ReportIOErrorIfNeeded:491 :[7975731566] IO-ERROR Type WRITE. comb: 69a3001d80b6. offsetInComb 2749760. SizeInLB 8. SDS_ID facbf26e0000001f. Comb Gen 1. Head Gen 136. StartLB a7c07d4 2020-02-26T06:33:26.557Z cpu23:2109794)scini: mapVolIO_ReportIOErrorIfNeeded:512: ScaleIO:Vol ID 0xecadc19500000033. Last vol TGT fault status IO_FAULT_NOT_PRI(12) Reason (old SCSI gen without retry) RC (IO_FAULT_OLD_SCSI_GEN) Retry count (0) chan (1) 2020-02-26T06:33:26.557Z cpu23:2109794)WARNING: ScaleIO blkScsi_PrintIOInfo:3333 :hCmd 0x459ac1ce5bc0, OpCode 0x2a, rc 51 scsiStat 2, senseCode 6, asc 41, ascq 2 2020-02-26T06:33:26.557Z cpu13:2109975)ScsiDeviceIO: 3414: Cmd(0x459ac1ce5bc0) 0x2a, CmdSN 0xffffe001ee83fad0 from world 3042834 to dev "eui.36b1f928611380beecadc19500000033" failed H:0x0 D:0x2 P:0x0 Valid sense data: 0x6 0x29 0x2. 2020-02-26T06:33:26.557Z cpu13:2109975)ScsiCore: 1714: Power-on Reset occurred on eui.36b1f928611380beecadc19500000033 2020-02-26T06:33:26.557Z cpu13:2109975)ScsiDeviceIO: 3414: Cmd(0x459ac1d63980) 0x2a, CmdSN 0xffffe00205830340 from world 3042834 to dev "eui.36b1f928611380beecadc19500000033" failed H:0x0 D:0x2 P:0x0 Valid sense data: 0x6 0x29 0x2.
影响
IO 不受影响,这些错误是可重试的。峰值 I/O 流量可能会导致性能下降
Cause
群集中的其中一个 ESXi 主机配置错误 — VMFS。未设置 HardwareAcceleratedLocking。
在 vSphere 中,可以按文件系统或全局启用 ATS 锁定。在这种情况下,群集中的所有主机对其所有 VMFS 数据存储区都具有匹配的设置(仅限 ATS),但有一个主机全局禁用了它:
[root@ESXI01:~] cat /etc/vmware/esx.conf |grep HardwareAcceleratedLocking /adv/VMFS3/HardwareAcceleratedLocking = "0"
为了进行比较,每个数据存储的锁定设置正确 (ATS):
root@ESX01:~] esxcli storage vmfs lockmode list Volume Name UUID Type Locking Mode ATS Compatible ATS Upgrade Modes ATS Incompatibility Reason ------------------------- ----------------------------------- ------ ------------ -------------- ----------------- --------------------------- DAS149 5dc98f40-5c2f58a8-f5e3-e4434b90b4ca VMFS-6 ATS+SCSI false None Device does not support ATS PD1_00015 5df78825-074d4806-6836-e4434b90b4ca VMFS-6 ATS true No upgrade needed PD2_00016 5df788a4-91dd451e-f732-e4434b421db8 VMFS-6 ATS true No upgrade needed PD1_00017 5df87e5f-b80e78fe-0c4d-e4434b904750 VMFS-6 ATS true No upgrade needed PD1_00018_NOVADP 5df87fad-2a18dd10-3c38-e4434b913086 VMFS-6 ATS true No upgrade needed
Resolution
解决方法
在高级设置中启用 HardwareAcceleratedLocking。
受影响的版本
所有版本