PowerEdge:M1000e AG 交换机端口处于 persistentdisable 状态,并显示错误:“配置不支持”
Summary: PowerEdge M1000e:AG 交换机端口处于 persistentdisable 状态。
This article applies to
This article does not apply to
This article is not tied to any specific product.
Not all product versions are identified in this article.
Symptoms
影响:
F 端口输入端口 persistentdisable 状态,并且无法更改为启用状态。
环境:
访问网关模式下
的 DELL PowerEdge M1000e
和 Brocade M6505问题:
F 端口卡在永久禁用状态。
在 Access Gateway 重新启动后,端口变为永久禁用状态。
示例:
switchshow : switchName: switchname switchType: 130.0 switchState: Online switchMode: Access Gateway Mode switchWwn: 10:00:00:00:00:00:00:00 switchBeacon: OFF Index Port Address Media Speed State Proto ================================================== <truncated> 6 6 010600 cu N16 In_Sync FC Disabled (Persistent) 7 7 010700 cu N16 Online FC F-Port <pwwn> 8 8 010800 cu N16 In_Sync FC Disabled (Persistent)
尝试更改为 persistentenabling 的端口:
switchname:admin> portcfgpersistentenable 8 Port 8: portcfgpersistentenable failed. Configuration is not capable(8).
Cause
端口卡住 persistentdisable 配置。
Resolution
步骤:
- 收集
ag --mapshow output以查看 F 端口映射到哪个 N 端口的位置。 - 使用以下命令将端口设置回出厂默认值
<portcfgdefault (port no) >。
示例: portCfgDefault 8
- 如果端口不在 中,使用命令 switchshow 检查端口状态
persistentdisable州。
示例:之后
portcfgdefault 命令,则状态更改为: In_Sync FC Disabled (No mapping for F-Port)
- 使用以下命令启用端口:
portenable (port no)。 - 使用以下命令将端口映射回原始 N 端口:
ag –mapadd (n-port) (f-port)。
示例:
ag --mapadd 20 "8"
- 使用以下命令检查端口是否映射到 N 端口:
ag --mapshow。 - 使用以下命令检查端口状态:
switchshow。预计端口处于联机状态。
示例:
Online FC F-Port
Affected Products
Brocade M6505, PowerEdge M1000EArticle Properties
Article Number: 000185988
Article Type: Solution
Last Modified: 12 Jun 2025
Version: 3
Find answers to your questions from other Dell users
Support Services
Check if your device is covered by Support Services.