PowerFlex: BAT1025 Integrated RAID Controller 1 is unable to recover cached data

Summary: Dial-Home Alert BAT1025 is generated in a VxRack FLEX environment. This indicates a failed RAID controller.

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Symptoms

A VxRack FLEX Alert Connector Dial-Home is generated with the following error:

BAT1025: Integrated RAID Controller 1 is unable to recover cached data from the Battery Backup Unit (BBU).



Example error from iDRAC Logs (Tesseract):
BAT1025: Integrated RAID Controller 1 is unable to recover cached data from the Battery Backup Unit (BBU). 


 

Cause

RAID Controller Hardware failure 

Resolution

Do one or all of the following:

1) Ensure that the PERC firmware version is updated.

2) Check the battery health. If there are battery issues, replace the battery. Else, replace the PERC card. 

Affected Products

PowerFlex Software, VxFlex Ready Node
Article Properties
Article Number: 000056251
Article Type: Solution
Last Modified: 24 Nov 2025