Instructions

Dell Vostro laptops have a long history of integrated diagnostic indicators. The following methods are used to indicate at which point during the Power-On Self-Test (POST) a laptop is having issues:

  • Audible beeps
  • Power buttons that display different states and colors
  • Specific diagnostics LEDs
  • A combination of them all

The following article is a reference guide to the codes available on each model and what those codes mean. These change through the various models and years. These indicators are merely a starting point that narrows down any troubleshooting you must carry out to identify the cause of your current issue. You can use this to narrow down the proper troubleshooting guide you require. Alternatively, you can contact technical support for further help and they are looking for these indicators as well.


Table of Contents:

  1. Diagnostic LEDs for the Vostro laptop series (2015 to 2025)
  2. Diagnostic LEDs for the Vostro laptop series (2010 to 2015)
  3. Diagnostic LEDs for the Vostro laptop Series (Prior to 2010)
  4. Vostro laptop Audible Beep Codes
  5. Glossary of Acronyms

Note: For all the tables below, remember that the diagnostic LEDs only serve as an indicator of the progress through the POST process. These LEDs do not indicate the problem that caused the POST routine to stop.
Note: You are experiencing a No Boot if your laptop completes POST without stopping on a particular error code and then gives a black screen. The most likely reason is an issue with the operating system or storage media.

Back to Top


Diagnostic LEDs for the Vostro laptop series (2015 to 2025)

With the latest series, the diagnostics indicator Beeps have mostly been removed from these laptops. Instead the Power Button state now gives a blink and color shift pattern to indicate where it is having a problem.

Vostro prod shot 2017

Note: Click the title of the section that you want to open below, in order to see the contents.
Note: Diagnostic Error Codes always supersede any other use of the LED. For instance, battery codes for Low Battery or Battery Failure situations are not displayed when Diagnostic Error Codes are being displayed.

Vostro Battery Status LED

Power Source Status Power State Description
AC Adapter Off S0 - S5 Fully Charged
White S0 - S5 Charging
Battery Off S0 - S5 Battery Discharging
Solid Amber S0 - S5 Low to Critically Low
  • S0 - ON - System is on
  • S4 - Hibernate - System in hibernation mode
  • S5 - OFF - System is off
Note: The blinking patterns consist of two sets of numbers. These are the First Group (Amber Blinks), and the Second Group (White Blinks).
  • First Group: The Battery LED blinks in Amber up to nine times then pauses for 1.5 seconds before running the second group.
  • Second Group: The Battery LED blinks in White up to nine times then pauses for 3 seconds before running the first group again.

Example: No Memory detected (2, 3), The Battery LED blinks two times amber followed by a pause, then blinks three times white, pause, and so on. This pattern continues until the laptop is turned off.
Power LED Problem Description Suggested Resolution
Amber White
2 1 CPU Failure
  • Run the Intel CPU diagnostics tools
  • If the problem persists contact Tech Support for further help
2 2 System Board: BIOS ROM Failure
  • Flash BIOS to latest revision
  • If the problem persists contact Tech Support for further troubleshooting
2 3 No Memory/RAM detected
  • Confirm Memory installed
  • Troubleshoot memory further
2 4 Memory/RAM failure
  • Reseat the Memory
  • Troubleshoot the memory further
2 5 Invalid Memory Installed
  • Reseat the Memory
  • Troubleshoot the memory further
2 6 System board, Chipset Error
  • Flash BIOS to latest revision
  • Contact Tech Support for further troubleshooting
2 7 LCD failure
  • Flash BIOS to latest revision
  • Contact Tech Support for further troubleshooting
3 1 CMOS battery failure
  • Troubleshoot the CMOS battery
  • If the problem persists contact Tech Support for further troubleshooting
3 2 PCI or Video card/chip failure
  • Contact Tech Support for further troubleshooting
3 3 BIOS Recovery 1
  • Recovery Image not found
  • Contact Tech Support for further troubleshooting
3 4 BIOS Recovery 2
  • Recovery image found but invalid
  • Contact Tech Support for further troubleshooting
3 5 Power Rail Failure
  • EC ran into power sequencing failure
  • Contact Tech Support for further troubleshooting
3 6 SBIOS Flash Corruption
  • Flash corruption detected by SBIOS
  • Contact Tech Support for further troubleshooting
3 7 ME Error
  • Timeout waiting on ME to reply to HECI message
  • Contact Tech Support for further troubleshooting
4 1 Memory Dual Inline memory module (DIMM) Power rail failure
  • Reset and swap the memory among the available slots
  • If the issue persists, it is a memory module failure
4 2 CPU Power Cable Connection Issue
  • Run the Power Support Unit (PSU) Built-In Self-Test (BIST)
  • If the issue continues, it is an issue with the motherboard, PSU, and cabling

Back to Top


Diagnostic LEDs for the Vostro laptop series (2010 to 2015)

With this series of laptops, the Diagnostic indicators changed to use two different methods depending on the model of laptop you have:

  • One method uses only the Power LED as an indicator. The Diagnostic LED is now the state of the Power LED and how many times it blinks at you.
  • The other method uses the beep codes from the beep code section.

Vostro 5460

Power LED State Description
PowerLEDOff
  • Hibernate or Suspend to Disk (S4)
  • Power is off (S5)
PowerLEDWhite The laptop is in S0 state, the normal power state of a functioning machine. The BIOS turns the LED to this state to indicate it has started fetching opcodes.
BlinkingWhite Laptop is in a low power state, either S1 or S3. This does not indicate a fault condition.
Warning: The power LED only serves as an indicator of the progress through the POST process. These LEDs do not indicate the problem that caused the POST routine to stop.
Note: The Power button has a bicolor LED. In a No Post situation, it displays an Amber LED blinking pattern: The Power Button LED shall blink the corresponding LED codes for the corresponding fault condition. The repeated pattern has a three second long pause inserted in the middle.

Example: No Memory detected, Power Button LED blinks two times followed by a pause, blinks two times, pause, and so on. This pattern continues until the laptop is turned off.
LED Behavior Problem Description Next Steps
1 System Board: BIOS ROM Failure
  • Flash BIOS to latest revision
  • If the problem persists contact Tech Support for further troubleshooting
2 No Memory/RAM detected
  • Confirm Memory installed
  • Troubleshoot memory further
3 System board, Chipset Error, Clock Failure, Gate A20 Failure, Super I/O Failure, Keyboard controller failure
  • Contact Tech Support for further troubleshooting
4 Memory/RAM failure
  • Reseat the Memory
  • Troubleshoot the memory further
5 CMOS battery failure
  • Troubleshoot the CMOS battery
  • If the problem persists contact Tech Support for further troubleshooting
6 Video card/chip failure
  • Contact Tech Support for further troubleshooting
7 CPU Failure
  • Run the Intel CPU diagnostics tools
  • Contact Tech Support for further troubleshooting

This indicates the Battery power management LEDs codes.

Power Source; Battery Charge Off/Hibernate Standby On
Power LED (All; 0-100% charge) Off Blinking White light (repeated) Solid White
Battery LED (AC Adapter; 98-100% charged) Off Off Off
Battery LED (AC Adapter; Below 98% charging) Solid White Solid White Solid White
Battery LED (Battery; discharging) Off Solid Amber Solid Amber
Battery LED (Battery; Below 10% critically low) Off Off Off
Hard drive LED Off Off White when active
Camera LED (All sources; 0-100% charge) Off Off Sold White when streaming data

Back to Top


Diagnostic LEDs for the Vostro laptop series (Prior to 2010)

This series used power button LED states and a diagnostics LED pack on laptops.

Vostro 3700

Note: Click the title of the section that you want to open below, in order to see the contents.

These models had a block of keyboard status LEDs on the front of the chassis that either lit up solid white, flashed white or were Off. The table below shows what these indicate.

Caps Lock LEDs

Icon Description
Caps Caps Lock light - Turns on when the Caps Lock is engaged.
Scroll Scroll Lock light - Turns on when the Scroll Lock is engaged.
Num Number Lock light - Turns on when the Number Lock is enabled.
Flash Code LED Pattern Description Next Step
D1 Flash-On-On The microcontroller is handing control of the laptop to the processor. This code persists if no processor is detected.
  • Reseat the processor
  • Contact Support
D2 On-Flash-On The memory has encountered an error.
  • Reseat the memory modules
  • Contact Support
D3 Flash-Flash-Flash A system board component is faulty.
  • Contact Support
D4 Flash-Flash-On The video card is preventing the laptop from completing POST.
  • Contact Support
D5 Flash-Flash-Off The keyboard is preventing the laptop from completing POST.
  • Reseat the keyboard cable
  • Contact Support
D6 Flash-Off-Flash The USB controller encountered a problem during initialization.
  • Remove any USB devices
  • Contact Support
D7 On-Flash-Flash No SODIMMs are installed.
  • Install the memory modules
  • Reseat the memory modules
  • Contact Support
D8 Flash-On-Flash The LCD encountered a problem during initialization.
  • Reseat the LCD cable
  • Contact Support
D9 Off-Flash-Flash The modem is preventing the laptop from completing POST.
  • Reseat the modem
  • Contact Support

System Status LEDs

If the laptop is running on a battery, the battery light operates as follows:

  • Off — The battery is adequately charged (or the laptop is turned off).
  • Flashing Amber — The battery charge is low.

Back to Top


Vostro laptop audible Beep codes

In addition to the various types of diagnostics LEDs, there are some audible beep codes across some of the models of these laptops.

These codes are recognized across manufacturers and have remained the same for some time.

The key to these codes is displayed in the table below.

Note: Click the title of the section that you want to open below, in order to see the contents.
Beep Code Description Failure Coverage Suggested Action
1 System board covers BIOS corruption or ROM error. System board BIOS ROM failure Run the Dell Diagnostics
2 No Memory/RAM Detected No memory detected Troubleshoot the Memory
3
  • Chipset Error (North and South bridge error, DMA/IMR/Timer error
  • Time-of-Day Clock failure
  • Gate A20 failure
  • Super I/O Failure
  • Keyboard controller failure
System board failure Run the Dell Diagnostics
4 Memory/RAM read/write failure Memory failure Troubleshoot the Memory
5 Real-Time Clock power fail COMS battery failure Try reseating the CMOS Battery and run the Dell Diagnostics if that does not resolve the issue.
6 Video card/chip Failure Video BIOS Run the Dell Diagnostics
7 CPU Cache Test Failure CPU Failure Run the Dell Diagnostics
8 LCD LCD Failure Contact Technical Support

Back to Top


Glossary of Acronyms:

See the table for definitions of the acronyms within this article.

Acronym Definition
BIOS Basic Input/Output System
CFG Resource Configuration
CPU Central Processing Unit
DIMM Dual In-line memory module
DMA Direct Memory Access
EC Embedded Controller
HECI Host Embedded Controller Interface
LCD Liquid Crystal Display
LED Light Emitting Diode
MBF Motherboard Failure
MBIST Memory Built-in Self-Test
ME Management Engine
MEM Memory
NVRAM Non-Volatile Random Access Memory
PCI Peripheral Component Interconnect
POV Post-video Activity
PRV Pre-video Activity
PSU Power Supply Unit
RAM Random Access Memory
RCM Recovery Mode
ROM Read-Only Memory
RTC Real-Time Clock
S0 System Power State S0 - This is the Working State, where your Windows laptop is awake.
S1 System Power State S1 - In this sleep state, the CPU is stopped, and your laptop is in standby mode.
S2 System Power State S2 - This state is similar to S1 except that the CPU and system cache are lost because the processor loses power.
S3 System Power State S3 - In this state, data is saved to RAM, hard drives, and other hardware are shut down.
S4 System Power State S4 - In this state, RAM and other data are saved to the hard disk.
S5 System Power State S5 - The System is off.
SBIOS Small Board Interface Operating System
SPI Serial Peripheral Interface
STD Boot Hand Off
STO Storage Device
TPM Trusted Platform Module
USB Universal Serial Bus
VID Video

Back to Top


Note:
Follow the instructions if you are seeing a recognizable code. If you have to contact your local support, ensure that you have the code information to hand. The technician needs this information to help you further.

If you are seeing an unrecognizable code, one that is not listed above - then get in touch with your local support straight away.

If you require further assistance: Contact Dell Technical Support.

Back to Top

Additional Information

Affected Products

Vostro
Article Properties
Article Number: 000141346
Article Type: How To
Last Modified: 16 Jun 2025
Version:  9
Find answers to your questions from other Dell users
Support Services
Check if your device is covered by Support Services.