PowerFlex 3.5 Sunum Sunucusu: Bildirilen Ağ Uyarıları Temizlenemedi

Summary: Sunum Sunucusu tarafından bildirilen ağ uyarılarını temizleyemiyorsunuz.

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Symptoms

Senaryo
Uyarılar SCLI kullanılarak temizlenebilse de, Sunu Sunucusu bilgilerini güncelleştirmez.

Belirti -leri
SCLI'da komutların verildiğini ve olaylarda başarılı olarak işaretlendiğini görürsünüz:
scli --reset_oscillating_failure_counters --all_counters --failure_counter sdc_sds_network_disconnections --all_sdc

events.txt
2021-04-07 07:53:02.005 MDM_CLI_CONF_COMMAND_RECEIVED INFO        Command reset_oscillating_failure_counters received, User: 'admin'. [68845913] Protection domain: N/A, Storage pool: N/A, MDM: N/A, Failure counter: sdc_sds_network_disconnections, All SDS: no, All SDC: yes, All devices: no, All MDM: no, All counters: yes
2021-04-07 07:53:02.006 CLI_COMMAND_SUCCEEDED     INFO            Command reset_oscillating_failure_counters succeeded.

Sunum Sunucusu - scaleio.log
MDM ile arasında bir bağlantı sorunu var gibi görünüyor:
2021-04-20 00:23:06,622 [RxCachedThreadScheduler-5|ERROR|com.emc.vxflexos.webui.backend.connection.mdm.MdmBackendServiceImpl.getResErrorMaybe] Error in request: com.emc.ecs.api.net.gen.QueryOscillatingNetworkCountersRequest --? error code: TIMEOUT  error info: null
2021-04-20 03:41:24,163 [RxCachedThreadScheduler-3|ERROR|com.emc.vxflexos.webui.backend.connection.mdm.MdmBackendServiceImpl.getResErrorMaybe] Error in request: com.emc.ecs.api.net.gen.QueryOscillatingNetworkCountersRequest --? error code: TIMEOUT  error info: null
2021-04-20 06:46:21,235 [Repository-UpdatePool-32|ERROR|com.emc.vxflexos.webui.backend.connection.mdm.MdmBackendServiceImpl.lambda$requestInternal$21] Failed to send request QueryOscillatingNetworkCountersRequest
2021-04-20 07:00:43,197 [RxCachedThreadScheduler-5|ERROR|com.emc.vxflexos.webui.backend.connection.mdm.MdmBackendServiceImpl.getResErrorMaybe] Error in request: com.emc.ecs.api.net.gen.QueryOscillatingNetworkCountersRequest --? error code: TIMEOUT  error info: null
2021-04-20 10:11:58,912 [RxCachedThreadScheduler-5|ERROR|com.emc.vxflexos.webui.backend.connection.mdm.MdmBackendServiceImpl.getResErrorMaybe] Error in request: com.emc.ecs.api.net.gen.QueryOscillatingNetworkCountersRequest --? error code: TIMEOUT  error info: null

Sunu sunucusu MDM'de oturum açar ve sorguyu verir, ancak daha sonra oturumu kapatılır: 
2021-04-20 22:48:21,131 [LiveQueryQueueThreadV2|INFO |com.emc.vxflexos.webui.backend.services.AutoLinkService.lambda$null$35] User xxxxxxxxxxxxxxx logged in. Hashed connection token: xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx
2021-04-20 22:48:21,131 [LiveQueryQueueThreadV2|INFO |com.emc.vxflexos.webui.backend.services.RepositoryUserManager.lambda$setCredentials$7] Changing credentials for com.emc.vxflexos.webui.backend.services.TokenManagerImpl@9a20cbd[1504611649] to : xxxxxxxxxxxxxxx 
2021-04-20 22:48:21,117 [Repository-UpdatePool-11|ERROR|com.emc.vxflexos.webui.backend.connection.mdm.MdmBackendServiceImpl.lambda$requestInternal$21] Failed to send request QueryOscillatingNetworkCountersRequestjava.lang.Exception: Cleared the connection token used for the request as it was invalid. Login again is needed for a new token. at com.emc.vxflexos.webui.backend.connection.mdm.MdmBackendServiceImpl.lambda$requestInternal$15(MdmBackendServiceImpl.java:106) ~[backend-mdm-3.5.1100.105.jar:?] 

İstek sırasında ZAMAN AŞIMI var:
2021-04-13 19:20:32,788 [RxComputationThreadPool-1-ReceiveLoop-802555786|INFO |com.emc.vxflexos.webui.backend.connection.mdm.MdmConnectionImpl.emitConnectionStatus] Connection status is changing to ConnectionStatus{status=Connecting, statusInfo=Got disconnected event from connection, the LPC will try to reconnect automatically, connectionToken=null, userName=null, userRole=INVALID, passwordChangeRequired=false, hosts=[HostInfo{nameOrIp=x.x.x.x, port=6611}, HostInfo{nameOrIp=x.x.x.x, port=6611}, HostInfo{nameOrIp=x.x.x.x, port=6611}, HostInfo{nameOrIp=x.x.x.x, port=6611}, HostInfo{nameOrIp=x.x.x.x, port=6611}, HostInfo{nameOrIp=x.x.x.x, port=6611}, HostInfo{nameOrIp=x.x.x.x, port=6611}], banner=null, unAutorizedCerificate=null}
2021-04-13 19:20:32,788 [RxCachedThreadScheduler-5|ERROR|com.emc.vxflexos.webui.backend.connection.mdm.MdmBackendServiceImpl.getResErrorMaybe] Error in request: com.emc.ecs.api.net.gen.QueryPropertiesRequest --? error code: TIMEOUT  error info: null
2021-04-13 19:20:32,788 [RxComputationThreadPool-1-ReceiveLoop-802555786|INFO |com.emc.ecs.net.connection.LayeredProtocolConnection.infoWithState] LPC-802555786 #e2b5f87e729ba7fe [x.x.x.x:6611]: Attempting to re-connect

MDM - trc.x
8/04 21:08:27.693637 0x7fcf26b63db0:netPath_IsKaNeeded:02298: :: Connected Live SERVER path 0x7fcf309d8be0 of portal 0x7fcf31786320 net 0x7fcf3011c700 socket 66 inflights 0 HS:0 didn't receive message for 20 iterations from x.x.x.x:37796. Marking as down

Etki
Kozmetik sorunu

Cause

MDM ile Sunu Sunucusu arasında bağlantı sorunu

Resolution

  1. Mümkünse iletişim sorununu tespit edin ve çözün.
  2. Değilse:
    • Sunum sunucusunda oturum açın ve sistemin bağlantısını kaldırın
    • MDM'yi değiştir
    • Sunum Sunucusunu Yeniden Bağlama

Additional Information

Etkilenen Sürümler
3.5

Düzeltildi Sürüm
Yok - bir PowerFlex sorunu değil

Affected Products

PowerFlex rack, VxRack, VxFlex Ready Nodes, PowerFlex Appliance, ScaleIO
Article Properties
Article Number: 000192262
Article Type: Solution
Last Modified: 28 Apr 2025
Version:  5
Find answers to your questions from other Dell users
Support Services
Check if your device is covered by Support Services.