PowerProtect Data Manager: Data Domain-Data Domain Boost Integration Fails, NFSv3 Not Enabled

Summary: PowerProtect Data Manager ServerDR backup fails because NFSv3 is not Enabled.

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Symptoms

PowerProtect Data Manager ServerDR backup fails with the following error.

"serverdr.log: 
2025-03-25T09:22:40.031Z WARN [] [autoConfig-1] [][][][TRACE_ID:aa7cf3b8908cd0ee;JOB_ID:9cf31b97440e2cd0][] 
[c.e.d.e.c.s.c.u.ExecuteCommand.exec(146)] - Cannot mount /data01/server_backups: unexpected error, please see log for details. serverdr.log: 
2025-03-25T09:22:40.031Z ERROR [] [autoConfig-1] [][][][TRACE_ID:aa7cf3b8908cd0ee;JOB_ID:9cf31b97440e2cd0][] 
[c.e.d.e.c.s.c.s.i.AutoConfigServiceImpl.setConfiguration(963)] - Unable to switch the DD Boost Configuration for the primary source: 
com.emc.dpsg.ecdm.cs.serverdr.core.exception.SdrException: SDR_MOUNT_FAILED_WITH_ERROR code=424 reason="Make sure that the original Data Manager Hostname and admin passwords are correct." remediation="none" "

The key line to notice is: 

"Unable to switch the DD Boost Configuration for the primary source"

Cause

Dell Data Domain Boost works over NFSv3. NFSv3 must be enabled. 

  • When checking the Network File System (NFS) status on the Data Domain:
sysadmin@DD# nfs status
The NFS system is currently not active.
  • From ddfs.info log:
03/26 11:16:55.135086 [7fc9c230b590] nfsproc3_ostmntsec_3_svc(): Client 100..x.x.x authenticated successfully
03/26 11:16:55.195740 [7fc9c3cbdf90] ddboost: <xxxxxx-49326>, cipher_info: 0, cipher_strength: 2, auth_mode: 3
03/26 11:16:55.292118 [7fc9c3cc5a10] mountproc3_mnt_3_svc_internal from 100.x.x.x/xxxxx succeeded for export point /data/col1/
03/26 11:16:55.292863 [7fc9c3cc4960] WARNING: MSG-NFS-00008: Rejecting NFS/TCP request from 100.x.x.x/xxxxxxxxx (disabled)!
03/26 11:16:55.293504 [7fc9c2302d10] SSL_read get error 5 [None 0]
03/26 11:16:55.293599 [7fc9c2302d10] nfs_rpc_svc_idx0 destroyed tcp da9

Resolution

Enable the NFSv3 protocol on Data Domain to successfully integrate PowerProtect Data Manager with Data Domain, also for ServerDR and Recover PowerProtect Data Manager from server DR backups to work properly. 

  • To enable NFS on Data Domain, from Data Domain SSH type:
nfs enable

Or

  • Use PowerProtect DD System Manager UI to enable NFS:

Select Protocols > NFS > then click Enable on NFSv3 Status

Additional Information

Dell Data Domain Boost requires additional NFSv3. Ports 111, 2049, and 2052 should be open and available. 

Affected Products

PowerProtect Data Manager

Products

Avamar
Article Properties
Article Number: 000305777
Article Type: Solution
Last Modified: 10 Apr 2025
Version:  1
Find answers to your questions from other Dell users
Support Services
Check if your device is covered by Support Services.