PowerStore: System Health Checks detects recovery file
Summary: The System Health Checks detected unexpected recovery files.
Instructions
System Health may fail the FSCK Leftover Check and display a failure message such as "/cyc_var/cyc-cfg.txt.d/cyc-sys-mode-override.txt exists, please refer to (KB#000201738)" one of the following scenarios:
- Running a System Check using PowerStore Manager (UI) with the Run System Check option or with the Run Upgrade Extensions option:
- Running a System Check using PowerStore Manager (UI) with the Run Upgrade Extensions option (PowerStoreOS 2.1.x only)
- Running the System Health Service Script (svc_health_check) using an SSH connection:
[SVC:service@1KGRJM3-A user]$ svc_health_check run -rhc fsck_leftover_check Name Location Status Description FSCK Leftover Check node_a Failed /cyc_var/cyc-cfg.txt.d/cyc-sys-mode-override.txt exists, please refer to (KB#000201738) FSCK Leftover Check node_b Failed /cyc_var/cyc-cfg.txt.d/cyc-sys-mode-override.txt exists, please refer to (KB#000201738)
The above message indicates that unexpected recovery files were detected on the appliance.
If System Health detects this condition, NDU will fail resulting in a node failure. NDU and maintenance operations should not be performed until this issue is resolved.
Contact technical support for assistance. Reference KB # 000201738 for expedited attention and resolution.
Additional Information
For more information on System Health Checks, see KB 000198084 PowerStore: How to use the System Check feature or KB 000192601 PowerStore: How to Check the Health of the Cluster Before Software Upgrade Using Pre-Upgrade Health Check and System Check.
KB# 000214752 PowerStore: Landing Page for In Market (off-release) System Health Checks lists all the health checks in the Health Check thin package.