PowerStore: Heath Check package check for asymmetric ICM connections fails
Summary: System health check detected incorrect asymmetric intracluster management (ICM) connections.
This article applies to
This article does not apply to
This article is not tied to any specific product.
Not all product versions are identified in this article.
Symptoms
System Health may display failure of the symmetric ICM connection check with one of the following messages:
- "ICM connection: Nodea: DOWN, nodeb: UP (KB#000203115)"
- "ICM connection: nodea: UP, nodeb: DOWN (KB#000203115)"
This health check may occur in one of the following scenarios:
- Running a System Check using PowerStore Manager (UI) with the Run System Check option
- Running a System Check using PowerStore Manager (UI) with the Run Upgrade Extensions option (PowerStoreOS 2.1.x only)
- Running the System Health Service Script (svc_health_check) using an SSH connection:
[SVC:root@ABCDEF-A ~]$ svc_health_check run -rhc symmetric_icm_connection -p Upgrade_Extensions
Name Location Status Description
Symmetric ICM Connec.. node_b FAILED ICM connection: nodea: DOWN, nodeb:
UP (KB#000203115)
When this issue exists, the NDU fails.
Cause
The above message indicates that one node has an ICM connection while the other node does not have an ICM connection.
Resolution
Do not proceed with NDU or maintenance operations if this condition is detected.
To resolve this issue, ensure that all ports and cables are connected properly, and all related alerts are resolved. If the issue persists, contact technical support for assistance. Reference KB #000203115 for expedited attention and resolution.
To resolve this issue, ensure that all ports and cables are connected properly, and all related alerts are resolved. If the issue persists, contact technical support for assistance. Reference KB #000203115 for expedited attention and resolution.
Additional Information
For more information about System Health Checks, see KB 000198084 PowerStore: How to use the System Check feature or KB 000192601 PowerStore: How to Check the Health of the Cluster Before Software Upgrade Using Pre-Upgrade Health Check and System Check.