PowerStore:系統執行狀況檢查失敗,「BBU 感應器檢查失敗node_x節點 X 上偵測到不相符的零件編號 (KB#000196197)」

Summary: 執行 PowerStore 系統執行狀況檢查失敗,因為「BBU 感應器檢查失敗node_x節點 X 上偵測到不相符的零件編號 (KB#000196197)」

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Symptoms

兩個節點上的系統執行狀況檢查 (SHC) 測試均失敗「bbu_sensor_check」,報告「偵測到的零件編號不相符」
 
[SVC:service@XXXXXXX-A user]$ svc_health_check run


 
{code}
Name                               Location  Status     Description                                                                                                                                                                    
Internal Disk Space                node_a    PASSED                                                                                                                                                                                    
Internal Disk Space                node_b    PASSED                                                                                                                                                                                    
CPU IERR Check                     node_a    PASSED                                                                                                                                                                                    
CPU IERR Check                     node_b    PASSED                                                                                                                                                                                    
ICD Network Connectivity Check     node_a    PASSED     Test not needed for Block only (Single appliance) or HCI                                                                                                                       
Drive Flags Check                  node_a    PASSED                                                                                                                                                                                    
Configuration Database             node_a    PASSED                                                                                                                                                                                    
Configuration Database             node_b    PASSED                                                                                                                                                                                    
Duplicate firmware entry Check     node_a    PASSED                                                                                                                                                                                    
Duplicate firmware entry Check     node_b    PASSED                                                                                                                          
Disk Health                        node_a    PASSED                                                                                                                                                                                    
DIMM Health                        node_a    PASSED                                                                                                                                                                                    
OS package name check              node_a    PASSED                                                                                                                                                                                    
Active System Alerts Check         node_a    PASSED                                                                                                                                                                                    
External Management Network        node_a    PASSED                                                                                                                                                                                    
Symmetric ICM Connection Check     node_a    PASSED                                                                                                                                                                                    
Time skew Check                    node_a    PASSED                                                                                                                                                                                    
I/O Ports                          node_a    PASSED                                                                                                                                                                                    
I/O Ports                          node_b    PASSED                                                                                                                                                                                    
recovery partition image check     node_a    PASSED                                                                                                                                                                                    
recovery partition image check     node_b    PASSED                                                                                                                                                                                    
REST Authorization Service         node_a    PASSED                                                                                                                                                                                    
REST Authorization Service         node_b    PASSED                                                                                                                                                                                    
Fru FW Upgrade Flag Check          node_a    PASSED                                                                                                                                                                                    
Initiator Connectivity Redundancy  node_a    PASSED                                                                                                                                                                                    
FSCK Leftover Check                node_a    PASSED                                                                                                                                                                                    
FSCK Leftover Check                node_b    PASSED                                                                                                                                                                                    
Pre-Upgrade Check                  node_a    WARNING                                                                                                                                                                                   
Pre-Upgrade Check                  node_b    PASSED                                                                                                                                                                                    
I/O Services Pre-Check             node_a    PASSED                                                                                                                                                                                    
I/O Services Pre-Check             node_b    PASSED                                                                                                                                                                                    
REST Configuration Service         node_a    PASSED                                                                                                                                                                                    
REST Data Service                  node_a    PASSED                                                                                                                                                                                    
Internal System Services           node_a    PASSED                                                                                                                                                                                    
Internal System Services           node_b    PASSED                                                                                                                                                                                    
Component SN Check                 node_a    PASSED                                                                                                                                                                                    
Component SN Check                 node_b    PASSED                                                                                                                                                                                    
DIMM correctable errors check      node_a    PASSED                                                                                                                                                                                    
DIMM correctable errors check      node_b    PASSED                                                                                                                                                                                    
kms lockbox file check             node_a    PASSED                                                                                                                                                                                    
Internal File System               node_a    PASSED                                                                                                                                                                                    
Internal File System               node_b    PASSED                                                                                                                                                                                    
DB Tmp Files Check                 node_a    PASSED                                                                                                                                                                                    
DB Tmp Files Check                 node_b    PASSED                                                                                                                                                                                    
Internal Management Network        node_a    WARNING                                                                                                                                                                                   
SAS Expansion Enclosure Check      node_a    PASSED                                                                                                                                                                                    
Operational Mode                   node_a    PASSED                                                                                                                                                                                    
Operational Mode                   node_b    PASSED                                                                                                                                                                                    
cyc_node space check               node_a    PASSED                                                                                                                                                                                    
cyc_node space check               node_b    PASSED                                                                                                                                                                                    

BBU Sensor Check                   node_a    FAILED     Mismatched part number detected on node A (KB#000196197)                                                                                                                       
BBU Sensor Check                   node_b    FAILED     Mismatched part number detected on node B (KB#000196197)
  
使用者介面硬體元件內部檢視顯示兩個節點的 BBU 狀況良好,但每個節點上的 BBU 零件編號不同。

BBU 硬體元件檢視節點 A

BBU 硬體元件檢視節點 B

svc_diag節點 A 和節點 B 上的硬體檢查顯示 BBU 正常。
針對兩個節點執行命令。
$ svc_diag list --hardware --sub_options fault_status
 
Hardware: ========== Fault Status register  ===========

Memory       dimm00: OK  | dimm01: OK  | dimm02: OK  | dimm03: OK  | dimm04: OK  | dimm05: OK  | dimm06: OK  | dimm07: OK  | 
             dimm08: OK  | dimm09: OK  | dimm10: OK  | dimm11: OK  | dimm12: OK  | dimm13: OK  | dimm14: OK  | dimm15: OK  | 
             dimm16: OK  | dimm17: OK  | dimm18: OK  | dimm19: OK  | dimm20: OK  | dimm21: OK  | dimm22: OK  | dimm23: OK  | 
EmbeddedDrve Drive00: OK  | Drive01: OK  | 
BackEndDrive Drive00: OK  | Drive01: OK  | Drive02: OK  | Drive03: OK  | Drive04: OK  | Drive05: OK  | Drive06: OK  | Drive07: OK  | 
             Drive08: OK  | Drive09: OK  | Drive10: OK  | Drive11: OK  | Drive12: OK  | Drive13: OK  | Drive14: OK  | Drive15: OK  | 
             Drive16: OK  | Drive17: OK  | Drive18: OK  | Drive19: OK  | Drive20: OK  | Drive21: OK  | Drive22: OK  | Drive23: OK  | 
             Drive24: OK  | 
I/O Module   iom00: OK  | iom01: OK  | 
Mezz         mez00: OK  | mez01: OK  | 
PSU          psu00: OK  | psu01: OK  | 

BBU          bbu00: OK  | bbu01: OK  | 
FAN          fan00: OK  | fan01: OK  | fan02: OK  | fan03: OK  | fan04: OK  | fan05: OK  | fan06: OK  | fan07: OK  | 
             fan08: OK  | fan09: OK  | fan10: OK  | fan11: OK  | fan12: OK  | fan13: OK  | 
Root I2C     i2c00: OK  | i2c01: OK  | i2c02: OK  | i2c03: OK  | i2c04: OK  | i2c05: OK  | i2c06: OK  | i2c07: OK  | 
IO I2C       i2c00: OK  | i2c01: OK  | i2c02: OK  | i2c03: OK  | i2c04: OK  | i2c05: OK  | i2c06: OK  | i2c07: OK  | 
Other I2C    i2c00: OK  | i2c01: OK  | i2c02: OK  | i2c03: OK  | i2c04: OK  | i2c05: OK  | i2c06: OK  | i2c07: OK  | 
Mezz I2C     i2c00: OK  | i2c01: OK  | i2c02: OK  | i2c03: OK  | i2c04: OK  | i2c05: OK  | i2c06: OK  | i2c07: OK  | 
Drive I2C    i2c00: OK  | i2c01: OK  | i2c02: OK  | i2c03: OK  | i2c04: OK  | i2c05: OK  | i2c06: OK  | i2c07: OK  | 
             i2c08: OK  | i2c09: OK  | i2c10: OK  | i2c11: OK  | i2c12: OK  | i2c13: OK  | i2c14: OK  | i2c15: OK  | 
             i2c16: OK  | i2c17: OK  | i2c18: OK  | i2c19: OK  | i2c20: OK  | i2c21: OK  | i2c22: OK  | i2c23: OK  | 
             i2c24: OK  | 

System       Bit  0  CPU Module: OK 
             Bit  1  Management Module: OK 
             Bit  2  Drive I/O Card 0: OK 
             Bit  3  eFlash : OK 
             Bit  4  Expansion Bay 0: OK 
             Bit  5  Enclosure: OK 
             Bit  6  CMI: OK 
             Bit  7  All Frus: OK 
             Bit  8  External: OK 
             Bit  9  Expansion Bay 1: OK 
             Bit 10  Drive I/O Card 1: OK                  

svc_diag顯示 BBU 0 和 1 的不同零件編號。
針對兩個節點執行命令。
$ svc_diag list --hardware --sub_options inventory |grep -A5 Battery
 
FRU Device Description : Battery0 (ID 9)
Board Mfg Date        : Tue Aug 18 00:00:00 2020
Board Mfg             : ACBEL POLYTECH INC.             
Board Product         : LITHIUM-ION, UNIVERSAL BOB      
Board Serial          : ACPW4211500063  
Board Part Number     :
078-000-177-02  
--
FRU Device Description : Battery1 (ID 10)
Board Mfg Date        : Wed Dec 11 00:00:00 2019
Board Mfg             : ACBEL POLYTECH INC.             
Board Product         : LITHIUM-ION, UNIVERSAL BOB      
Board Serial          : ACPV8200500140  
Board Part Number     :
078-000-168-02  
 

Cause

PowerStoreOS 2.1.x 和 3.x 的最新系統執行狀況檢查精簡型套裝發生問題,會錯誤地檢查兩個節點之間的 BBU 零件編號,如果兩者不相同,則會失敗。

自適用於 PowerStoreOS 2.1.X 的 PowerStore-health_check-2.1.1.1-1736451 以來的所有系統執行狀況檢查套件都會受到影響。
自適用於 PowerStoreOS 3.X 的 PowerStore-health_check-3.0.0.0-1781415 以來,所有系統執行狀況檢查套件都會受到影響。

PowerStore 支援 11 種不同的 BBU 零件編號,而且系統執行狀況檢查預期兩個 BBU 的 PN 相同,但事實可能並非如此。以下任何零件編號均有效且受支援。
078-000-168-02 078-000-177-02 078-000-192-00 078-000-195-03 078-000-211-01 088-000-168-02 088-000-177-02 088-000-192-00 088-000-195-03
088-000-211-00


088-000-211-01





Resolution

如果 BBU 處於健全狀況,且執行系統執行狀況檢查時產生的唯一錯誤,精簡型封裝為「BBU 感應器檢查失敗node_x節點 X 上偵測到不相符的零件編號 (KB#000196197)」,則可以忽略錯誤,並啟動 NDU。

此問題已在開發中的系統執行狀況檢查精簡套裝新版本中修正。

Affected Products

PowerStore
Article Properties
Article Number: 000212653
Article Type: Solution
Last Modified: 29 Jul 2025
Version:  6
Find answers to your questions from other Dell users
Support Services