PowerStore:“BBU 传感器检查失败,在节点 X 上检测到部件编号不匹配 (KB#000196197)”node_x系统运行状况检查失败

Summary: 由于“BBU Sensor Check node_x FAILED - Mismatched part number detected on node X (KB#000196197)”,运行 PowerStore 系统运行状况检查失败

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Symptoms

两个节点上的“bbu_sensor_check”系统运行状况检查 (SHC) 测试失败,并报告“检测到不匹配的部件编号”
 
[SVC:service@XXXXXXX-A user]$ svc_health_check run


 
{code}
Name                               Location  Status     Description                                                                                                                                                                    
Internal Disk Space                node_a    PASSED                                                                                                                                                                                    
Internal Disk Space                node_b    PASSED                                                                                                                                                                                    
CPU IERR Check                     node_a    PASSED                                                                                                                                                                                    
CPU IERR Check                     node_b    PASSED                                                                                                                                                                                    
ICD Network Connectivity Check     node_a    PASSED     Test not needed for Block only (Single appliance) or HCI                                                                                                                       
Drive Flags Check                  node_a    PASSED                                                                                                                                                                                    
Configuration Database             node_a    PASSED                                                                                                                                                                                    
Configuration Database             node_b    PASSED                                                                                                                                                                                    
Duplicate firmware entry Check     node_a    PASSED                                                                                                                                                                                    
Duplicate firmware entry Check     node_b    PASSED                                                                                                                          
Disk Health                        node_a    PASSED                                                                                                                                                                                    
DIMM Health                        node_a    PASSED                                                                                                                                                                                    
OS package name check              node_a    PASSED                                                                                                                                                                                    
Active System Alerts Check         node_a    PASSED                                                                                                                                                                                    
External Management Network        node_a    PASSED                                                                                                                                                                                    
Symmetric ICM Connection Check     node_a    PASSED                                                                                                                                                                                    
Time skew Check                    node_a    PASSED                                                                                                                                                                                    
I/O Ports                          node_a    PASSED                                                                                                                                                                                    
I/O Ports                          node_b    PASSED                                                                                                                                                                                    
recovery partition image check     node_a    PASSED                                                                                                                                                                                    
recovery partition image check     node_b    PASSED                                                                                                                                                                                    
REST Authorization Service         node_a    PASSED                                                                                                                                                                                    
REST Authorization Service         node_b    PASSED                                                                                                                                                                                    
Fru FW Upgrade Flag Check          node_a    PASSED                                                                                                                                                                                    
Initiator Connectivity Redundancy  node_a    PASSED                                                                                                                                                                                    
FSCK Leftover Check                node_a    PASSED                                                                                                                                                                                    
FSCK Leftover Check                node_b    PASSED                                                                                                                                                                                    
Pre-Upgrade Check                  node_a    WARNING                                                                                                                                                                                   
Pre-Upgrade Check                  node_b    PASSED                                                                                                                                                                                    
I/O Services Pre-Check             node_a    PASSED                                                                                                                                                                                    
I/O Services Pre-Check             node_b    PASSED                                                                                                                                                                                    
REST Configuration Service         node_a    PASSED                                                                                                                                                                                    
REST Data Service                  node_a    PASSED                                                                                                                                                                                    
Internal System Services           node_a    PASSED                                                                                                                                                                                    
Internal System Services           node_b    PASSED                                                                                                                                                                                    
Component SN Check                 node_a    PASSED                                                                                                                                                                                    
Component SN Check                 node_b    PASSED                                                                                                                                                                                    
DIMM correctable errors check      node_a    PASSED                                                                                                                                                                                    
DIMM correctable errors check      node_b    PASSED                                                                                                                                                                                    
kms lockbox file check             node_a    PASSED                                                                                                                                                                                    
Internal File System               node_a    PASSED                                                                                                                                                                                    
Internal File System               node_b    PASSED                                                                                                                                                                                    
DB Tmp Files Check                 node_a    PASSED                                                                                                                                                                                    
DB Tmp Files Check                 node_b    PASSED                                                                                                                                                                                    
Internal Management Network        node_a    WARNING                                                                                                                                                                                   
SAS Expansion Enclosure Check      node_a    PASSED                                                                                                                                                                                    
Operational Mode                   node_a    PASSED                                                                                                                                                                                    
Operational Mode                   node_b    PASSED                                                                                                                                                                                    
cyc_node space check               node_a    PASSED                                                                                                                                                                                    
cyc_node space check               node_b    PASSED                                                                                                                                                                                    

BBU Sensor Check                   node_a    FAILED     Mismatched part number detected on node A (KB#000196197)                                                                                                                       
BBU Sensor Check                   node_b    FAILED     Mismatched part number detected on node B (KB#000196197)
  
用户界面硬件组件内部视图显示两个节点的 BBU 运行状况良好,但每个节点上的 BBU 部件号不同。

BBU 硬件组件视图节点 A

BBU 硬件组件视图节点 B

svc_diag节点 A 和节点 B 上的硬件检查都显示 BBU 正常。
针对两个节点运行命令。
$ svc_diag list --hardware --sub_options fault_status
 
Hardware: ========== Fault Status register  ===========

Memory       dimm00: OK  | dimm01: OK  | dimm02: OK  | dimm03: OK  | dimm04: OK  | dimm05: OK  | dimm06: OK  | dimm07: OK  | 
             dimm08: OK  | dimm09: OK  | dimm10: OK  | dimm11: OK  | dimm12: OK  | dimm13: OK  | dimm14: OK  | dimm15: OK  | 
             dimm16: OK  | dimm17: OK  | dimm18: OK  | dimm19: OK  | dimm20: OK  | dimm21: OK  | dimm22: OK  | dimm23: OK  | 
EmbeddedDrve Drive00: OK  | Drive01: OK  | 
BackEndDrive Drive00: OK  | Drive01: OK  | Drive02: OK  | Drive03: OK  | Drive04: OK  | Drive05: OK  | Drive06: OK  | Drive07: OK  | 
             Drive08: OK  | Drive09: OK  | Drive10: OK  | Drive11: OK  | Drive12: OK  | Drive13: OK  | Drive14: OK  | Drive15: OK  | 
             Drive16: OK  | Drive17: OK  | Drive18: OK  | Drive19: OK  | Drive20: OK  | Drive21: OK  | Drive22: OK  | Drive23: OK  | 
             Drive24: OK  | 
I/O Module   iom00: OK  | iom01: OK  | 
Mezz         mez00: OK  | mez01: OK  | 
PSU          psu00: OK  | psu01: OK  | 

BBU          bbu00: OK  | bbu01: OK  | 
FAN          fan00: OK  | fan01: OK  | fan02: OK  | fan03: OK  | fan04: OK  | fan05: OK  | fan06: OK  | fan07: OK  | 
             fan08: OK  | fan09: OK  | fan10: OK  | fan11: OK  | fan12: OK  | fan13: OK  | 
Root I2C     i2c00: OK  | i2c01: OK  | i2c02: OK  | i2c03: OK  | i2c04: OK  | i2c05: OK  | i2c06: OK  | i2c07: OK  | 
IO I2C       i2c00: OK  | i2c01: OK  | i2c02: OK  | i2c03: OK  | i2c04: OK  | i2c05: OK  | i2c06: OK  | i2c07: OK  | 
Other I2C    i2c00: OK  | i2c01: OK  | i2c02: OK  | i2c03: OK  | i2c04: OK  | i2c05: OK  | i2c06: OK  | i2c07: OK  | 
Mezz I2C     i2c00: OK  | i2c01: OK  | i2c02: OK  | i2c03: OK  | i2c04: OK  | i2c05: OK  | i2c06: OK  | i2c07: OK  | 
Drive I2C    i2c00: OK  | i2c01: OK  | i2c02: OK  | i2c03: OK  | i2c04: OK  | i2c05: OK  | i2c06: OK  | i2c07: OK  | 
             i2c08: OK  | i2c09: OK  | i2c10: OK  | i2c11: OK  | i2c12: OK  | i2c13: OK  | i2c14: OK  | i2c15: OK  | 
             i2c16: OK  | i2c17: OK  | i2c18: OK  | i2c19: OK  | i2c20: OK  | i2c21: OK  | i2c22: OK  | i2c23: OK  | 
             i2c24: OK  | 

System       Bit  0  CPU Module: OK 
             Bit  1  Management Module: OK 
             Bit  2  Drive I/O Card 0: OK 
             Bit  3  eFlash : OK 
             Bit  4  Expansion Bay 0: OK 
             Bit  5  Enclosure: OK 
             Bit  6  CMI: OK 
             Bit  7  All Frus: OK 
             Bit  8  External: OK 
             Bit  9  Expansion Bay 1: OK 
             Bit 10  Drive I/O Card 1: OK                  

svc_diag显示了 BBU 0 和 1 的不同部件号。
针对两个节点运行命令。
$ svc_diag list --hardware --sub_options inventory |grep -A5 Battery
 
FRU Device Description : Battery0 (ID 9)
Board Mfg Date        : Tue Aug 18 00:00:00 2020
Board Mfg             : ACBEL POLYTECH INC.             
Board Product         : LITHIUM-ION, UNIVERSAL BOB      
Board Serial          : ACPW4211500063  
Board Part Number     :
078-000-177-02  
--
FRU Device Description : Battery1 (ID 10)
Board Mfg Date        : Wed Dec 11 00:00:00 2019
Board Mfg             : ACBEL POLYTECH INC.             
Board Product         : LITHIUM-ION, UNIVERSAL BOB      
Board Serial          : ACPV8200500140  
Board Part Number     :
078-000-168-02  
 

Cause

PowerStoreOS 2.1.x 和 3.x 的最新系统运行状况检查精简软件包中存在问题,该问题错误地检查两个节点之间的 BBU 部件编号,如果它们不相同,则失败。

自 PowerStore-health_check-2.1.1.1-1736451 以来适用于 PowerStoreOS 2.1.X 的所有系统运行状况检查程序包都会受到影响。
自 PowerStore-health_check-3.0.0.0-1781415 以来,所有适用于 PowerStoreOS 3.X 的系统运行状况检查软件包都会受到影响。

PowerStore 支持 11 个不同的 BBU 部件号,系统运行状况检查预计两个 BBU 的 PN 相同,但事实可能并非如此。以下任何部件号均有效且受支持。
078-000-168-02 078-000-177-02 078-000-192-00 078-000-195-03 078-000-211-01 088-000-168-02 088-000-177-02 088-000-192-00 088-000-195-03

088-000-211-00
088-000-211-01






Resolution

如果 BBU 处于正常运行状态,并且运行系统运行状况检查(该精简封装)生成的唯一错误是“BBU Sensor Check node_x FAILED Mismatched part number detected on node X (KB#000196197)”,则可以忽略该错误,并可以启动 NDU。

此问题已在开发中的系统运行状况检查精简软件包的新版本中得到修复。

Affected Products

PowerStore
Article Properties
Article Number: 000212653
Article Type: Solution
Last Modified: 29 Jul 2025
Version:  6
Find answers to your questions from other Dell users
Support Services
Check if your device is covered by Support Services.