Connectrix MDS 系列:由於系統錯誤代碼「0x42630007 mauler obt bist failure」,導致 FC 模組處於關閉電源狀態
Summary: 其中一個 F16 ASIC 上的內建自我測試 (BIST) 會偵測到硬體故障
Symptoms
連接埠刀鋒模組 上遇到的BIST (內建自我測試) 故障。`show module`
Mod Ports Module-Type Model Status
--- ----- ----------------------------------- ------------------ ----------
8 48 2/4/8/10/16 Gbps Advanced FC Module DS-X9448-768K9 powered-dn
`show module internal exceptionlog module 8`
Module Slot Number: 8
Device Id : 204
Device Name : F16 Generic Driver
Device Errorcode : 0xccc01400
Device ID : 204 (0xcc)
Device Instance : 01 (0x01)
Dev Type (HW/SW) : 04 (0x04)
ErrNum (devInfo) : 00 (0x00)
System Errorcode : 0x42630007 mauler obt bist failure
Error Type : Minor error
PhyPortLayer : Fibre Channel
Port(s) Affected : fc8/9-16
Error Description : hardware init failure
DSAP : 0 (0x0)
UUID : 1129 (0x469)
Time : Fri Jun 26 01:05:56 2020
(Ticks: 5EF59044 jiffies)
Mod Power-Status Reason
--- ------------ ---------------------------
8 powered-dn Reset (powered-down) because module does not boot
show logging log:
2020 Jun 26 01:04:06 CMISAN-10 %MODULE-2-MOD_SOMEPORTS_FAILED: Module 8 (Serial number: XXXXXXXXXXX) reported failure on ports fc8/9-16 (Fibre Channel) due to mauler obt bist failure in device DEV_F16_CMN (device error 0xccc01400)
2020 Jun 26 01:05:01 CMISAN-10 %PORT-5-MODULE_BRINGUP_NOT_ALLOWED: Not allowing module 8 to come up for reason: Device Name:[0xC4] Instance:[38] Error Type:[diag error] code:[0] (0xcc426300)
Cause
BIST (內建自我測試) 是 POST (開機自我測試) 的一部分。BIST 基本上是一種診斷測試,旨在偵測硬體故障。不同的交換器屬於 MDS 平台,支援一整套診斷測試,其中包括 BIST。
當晶片損毀時,BIST 會因此失敗。這是連接埠刀鋒模組內部其中一個 F16 ASIC 硬體故障的問題。
在上述情況下,負責連接埠 (9-16) 的其中一個 ASIC BIST 發生故障。
Resolution
由於這是硬體 ASIC 故障,因此需要更換模組。