Connectrix MDS 系列:由于系统错误代码“0x42630007 mauler obt bist failure”,FC 模块处于关闭状态
Summary: 其中一个 F16 ASIC 上的内置自检 (BIST) 检测到硬件故障
Symptoms
在端口刀片模块上遇到BIST(内置自检)故障。`show module`
Mod Ports Module-Type Model Status
--- ----- ----------------------------------- ------------------ ----------
8 48 2/4/8/10/16 Gbps Advanced FC Module DS-X9448-768K9 powered-dn
`show module internal exceptionlog module 8`
Module Slot Number: 8
Device Id : 204
Device Name : F16 Generic Driver
Device Errorcode : 0xccc01400
Device ID : 204 (0xcc)
Device Instance : 01 (0x01)
Dev Type (HW/SW) : 04 (0x04)
ErrNum (devInfo) : 00 (0x00)
System Errorcode : 0x42630007 mauler obt bist failure
Error Type : Minor error
PhyPortLayer : Fibre Channel
Port(s) Affected : fc8/9-16
Error Description : hardware init failure
DSAP : 0 (0x0)
UUID : 1129 (0x469)
Time : Fri Jun 26 01:05:56 2020
(Ticks: 5EF59044 jiffies)
Mod Power-Status Reason
--- ------------ ---------------------------
8 powered-dn Reset (powered-down) because module does not boot
show logging log:
2020 Jun 26 01:04:06 CMISAN-10 %MODULE-2-MOD_SOMEPORTS_FAILED: Module 8 (Serial number: XXXXXXXXXXX) reported failure on ports fc8/9-16 (Fibre Channel) due to mauler obt bist failure in device DEV_F16_CMN (device error 0xccc01400)
2020 Jun 26 01:05:01 CMISAN-10 %PORT-5-MODULE_BRINGUP_NOT_ALLOWED: Not allowing module 8 to come up for reason: Device Name:[0xC4] Instance:[38] Error Type:[diag error] code:[0] (0xcc426300)
Cause
BIST(内置自检)是 POST(开机自检)的一部分。BIST基本上是一种诊断测试,旨在检测硬件故障。作为 MDS 平台组成部分的不同交换机支持一整套诊断测试,其中包括 BIST。
当芯片损坏时,BIST 会失败。这是端口刀片模块内的一个 F16 ASIC 上的硬件故障。
在上面的案例中,负责端口 (9-16) 的其中一个 ASIC 的 BIST 失败。
Resolution
需要更换模块,因为这是硬件 ASIC 故障。