Connectrix MDS 系列:由于系统错误代码“0x42630007 mauler obt bist failure”,FC 模块处于关闭状态

Summary: 其中一个 F16 ASIC 上的内置自检 (BIST) 检测到硬件故障

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Symptoms



在端口刀片模块上遇到BIST(内置自检)故障。

`show module`
Mod  Ports  Module-Type                         Model              Status
---  -----  ----------------------------------- ------------------ ----------
8    48     2/4/8/10/16 Gbps Advanced FC Module DS-X9448-768K9     powered-dn

`show module internal exceptionlog module 8`
Module Slot Number: 8
Device Id         : 204
Device Name       : F16 Generic Driver
Device Errorcode  : 0xccc01400
Device ID         : 204 (0xcc)
Device Instance   : 01 (0x01)
Dev Type (HW/SW)  : 04 (0x04)
ErrNum (devInfo)  : 00 (0x00)
System Errorcode  : 0x42630007 mauler obt bist failure
Error Type        : Minor error
PhyPortLayer      : Fibre Channel
Port(s) Affected  : fc8/9-16
Error Description : hardware init failure
DSAP              : 0 (0x0)
UUID              : 1129 (0x469)
Time              : Fri Jun 26 01:05:56 2020
                    (Ticks: 5EF59044 jiffies) 

Mod  Power-Status  Reason 
---  ------------  ---------------------------
8    powered-dn     Reset (powered-down) because module does not boot

show logging log:

2020 Jun 26 01:04:06 CMISAN-10 %MODULE-2-MOD_SOMEPORTS_FAILED: Module 8 (Serial number: XXXXXXXXXXX) reported failure on ports fc8/9-16 (Fibre Channel) due to mauler obt   bist failure in device DEV_F16_CMN (device error 0xccc01400)
2020 Jun 26 01:05:01 CMISAN-10 %PORT-5-MODULE_BRINGUP_NOT_ALLOWED: Not allowing module 8 to come up for reason: Device Name:[0xC4] Instance:[38] Error Type:[diag error]   code:[0] (0xcc426300)

 

Cause

BIST(内置自检)是 POST(开机自检)的一部分。BIST基本上是一种诊断测试,旨在检测硬件故障。作为 MDS 平台组成部分的不同交换机支持一整套诊断测试,其中包括 BIST。

当芯片损坏时,BIST 会失败。这是端口刀片模块内的一个 F16 ASIC 上的硬件故障。

在上面的案例中,负责端口 (9-16) 的其中一个 ASIC 的 BIST 失败。

Resolution

需要更换模块,因为这是硬件 ASIC 故障。

Affected Products

Connectrix MDS-Series Hardware

Products

Connectrix MDS-Series Hardware
Article Properties
Article Number: 000082173
Article Type: Solution
Last Modified: 29 Sept 2025
Version:  3
Find answers to your questions from other Dell users
Support Services
Check if your device is covered by Support Services.