PowerStore Alerts: Network ICMP and MTU Size issues

Summary: This article discusses Network Ping Status Alerts.

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Symptoms

When Dell PowerStore encounters a problem, an error alert is generated to help identify the issue. This article explains the different possible causes and the relevant solutions for these error alerts. If your problem is not resolved despite the solution that is provided, check the technical support contact options.

Note: Having trouble finding the information needed? Let us know using the feedback form at the bottom of this article.

 

Cause

The cause is mentioned in the Resolution section under the respective alerts.

 

Resolution

Alert ID ONV_ICC_NETWORK_PING_STATUS_UNREACHABLE
Alert Text Network ICMP connectivity issues with %(count) addresses.
Error Code (0x01807802)
Impact Network connectivity may be limited.
Resolution Cause
Network ICMP connectivity issues.

Solution
Check cabling and VLAN configuration within the nodes and switches.

Alert ID ONV_ICC_NETWORK_PING_STATUS_MTU_ISSUES
Alert Text Network MTU size issues with %(count) addresses.
Error Code (0x01807803)
Impact Network connectivity may be limited.
Resolution Cause
Network MTU size issues.

Solution
Check the port MTU sizes of switches and ensure that they correspond to the network MTU. The required MTU value appears in the alert details.

Alert ID ONV_ICC_NETWORK_PING_STATUS_UNREACHABLE_AND_MTU_ISSUES
Alert Text Network ICMP connectivity and MTU size issues with %(count) addresses.
Error Code (0x01807804)
Impact Network connectivity may be limited.
Resolution Cause
Network ICMP connectivity and MTU size issues.

Solution
Check cabling, VLAN, and MTU settings within cluster nodes and switches to ensure switch port MTU sizes match the network MTU. Find the required MTU value in the alert details.

 

Additional Information

Alert code 0x01807802

If hosts are directly connected to the PowerStore I/O ports, this alert may reappear multiple times. See the following KB for more details: PowerStore: Direct Attached Hosts are Not Supported for iSCSI and NVMe TCP Over 4-Port Card Bond0 Ports. This alert can be ignored since there is no switch between the hosts and the cluster, but it cannot be disabled.

 