Connectrix MDS: Unexpected system time after switch restart
Summary: Users may encounter unexpected system time after an MDS switch reboot.
This article applies to
This article does not apply to
This article is not tied to any specific product.
Not all product versions are identified in this article.
Symptoms
After a switch reload or ISSU/D, unexpected system time may be encountered. This issue only happens if there are no NTP servers configured on the device.
Cause
This issue is discussed in Cisco Issue CSCvr13566 .
Known Affected NX-OS releases:
8.4(2c), 8.4(2a), 8.4(1a), 8.4(1), 8.3(1a), 8.2(1), and 8.1(1)
Resolution
Once the system clock is set using the EXEC level clock set command, wait for at least 30 minutes before reloading the switch or performing ISSU/D.
If the NTP feature is disabled, enable it first using the command feature ntp.
This issue is address in NX-OS version 8.4(2) and 8.4(2.93)S0.
Affected Products
Connectrix MDS-SeriesArticle Properties
Article Number: 000216210
Article Type: Solution
Last Modified: 18 Apr 2025
Version: 3