PowerProtect Data Manager: Replikeringsjob mislykkes med fejlen "ARP0030-Unable to setRetentionTime"
Summary: Replikeringsjob mislykkes med fejlmeddelelse ARP0030 fejlkode: Kan ikke indstilleRetentionTime.
This article applies to
This article does not apply to
This article is not tied to any specific product.
Not all product versions are identified in this article.
Symptoms
Replikeringsjob mislykkes, når fastholdelseslåsfunktionen er aktiveret i beskyttelsespolitikken.
Fejlmeddelelser, der ligner følgende, findes i joblogfilen eller replmgr.log filen:
Fejlmeddelelser, der ligner følgende, findes i joblogfilen eller replmgr.log filen:
replmgr.log: 2024-01-08T00:15:00.314Z INFO [] [replmgr-job-worker-thread-736] [00000000-0000-4000-a000-000000000000][][TASK_ID:81984b7f083ed690][TRACE_ID:a4f5c24e99a4c2d8;JOB_ID:b0f4954143a3b8b6][plc.id:169434fd,asset.id:641cf073,pcs.id:cdd721f7] c.e.brs.replmgr.service.ServiceUtils.getRetentionTime(139) - adhoc retention 7 YEAR replmgr.log: 2024-01-08T00:15:00.314Z INFO [] [replmgr-job-worker-thread-736] [00000000-0000-4000-a000-000000000000][][TASK_ID:81984b7f083ed690][TRACE_ID:a4f5c24e99a4c2d8;JOB_ID:b0f4954143a3b8b6][plc.id:169434fd,asset.id:641cf073,pcs.id:cdd721f7] c.e.brs.replmgr.service.ServiceUtils.getRetentionTime(142) - Retention time for backupLevel=FULL to: 2031-01-09T00:00:00Z lockStatus=true tags=[OperationId||618733f7-4b37-d911-e4b3-c3ebaf8a05d8, OperationId||9d9a39f6-f927-2b4d-5786-924e940ebaf6, OperationId||b0ab63e1-1d94-7eb6-dd5c-0936df8fe5ba] replmgr.log: 2024-01-08T00:15:00.314Z INFO [] [replmgr-job-worker-thread-736] [00000000-0000-4000-a000-000000000000][][TASK_ID:81984b7f083ed690][TRACE_ID:a4f5c24e99a4c2d8;JOB_ID:b0f4954143a3b8b6][plc.id:169434fd,asset.id:641cf073,pcs.id:cdd721f7] c.e.b.d.ddboost.DDBoostAdapter.skipRetentionTime(1765) - comparing existing retention-time=1970-01-01T00:00:00Z updateTo=2031-01-09T00:00:00Z replmgr.log: 2024-01-08T00:15:00.314Z INFO [] [replmgr-job-worker-thread-736] [00000000-0000-4000-a000-000000000000][][TASK_ID:81984b7f083ed690][TRACE_ID:a4f5c24e99a4c2d8;JOB_ID:b0f4954143a3b8b6][plc.id:169434fd,asset.id:641cf073,pcs.id:cdd721f7] c.e.b.d.ddboost.DDBoostAdapter.setRetentionTime(1776) - setting retention-time=2031-01-09T00:00:00Z for SU=StorageUnitName filepath=PLCTLP-xxxxxxx-xxxx-xxxx-xxxx-xxxxxxxxxxxx/Client_HostName/14/2.0/data_ss/MSSQL2%3aUsersRestore/FULL/_ts10k_170403/1704038856.ss replmgr.log: 2024-01-08T00:15:00.343Z ERROR [] [replmgr-job-worker-thread-736] [00000000-0000-4000-a000-000000000000][][TASK_ID:81984b7f083ed690][TRACE_ID:a4f5c24e99a4c2d8;JOB_ID:b0f4954143a3b8b6][plc.id:169434fd,asset.id:641cf073,pcs.id:cdd721f7] c.e.b.d.ddboost.DDBoostAdapter.copyFileSetRetentionTime(1738) - Unable to setRetentionTime for srcStorageUnit=StorageUnitName, dstStorageUnit=StorageUnitName, dstFilePath=PLCTLP-xxxxxxx-xxxx-xxxx-xxxx-xxxxxxxxxxxx/Client_HostName/14/2.0/data_ss/MSSQL2%3aUsersRestore/FULL/_ts10k_170403/1704038856.ss replmgr.log: 2024-01-08T00:15:00.343Z INFO [] [replmgr-job-worker-thread-736] [00000000-0000-4000-a000-000000000000][][TASK_ID:81984b7f083ed690][TRACE_ID:a4f5c24e99a4c2d8;JOB_ID:b0f4954143a3b8b6][plc.id:169434fd,asset.id:641cf073,pcs.id:cdd721f7] c.e.b.d.ddboost.DDBoostAdapter.skipRetentionTime(1765) - comparing existing retention-time=1970-01-01T00:00:00Z updateTo=2031-01-09T00:00:00Z replmgr.log: 2024-01-08T00:15:00.343Z INFO [] [replmgr-job-worker-thread-736] [00000000-0000-4000-a000-000000000000][][TASK_ID:81984b7f083ed690][TRACE_ID:a4f5c24e99a4c2d8;JOB_ID:b0f4954143a3b8b6][plc.id:169434fd,asset.id:641cf073,pcs.id:cdd721f7] c.e.b.d.ddboost.DDBoostAdapter.setRetentionTime(1776) - setting retention-time=2031-01-09T00:00:00Z for SU=StorageUnitName filepath=PLCTLP-xxxxxxx-xxxx-xxxx-xxxx-xxxxxxxxxxxx/Client_HostName/14/2.0/data_ss/MSSQL2%3aUsersRestore/FULL/_ts10k_170403/1704038853.ss replmgr.log: 2024-01-08T00:15:00.378Z ERROR [] [replmgr-job-worker-thread-736] [00000000-0000-4000-a000-000000000000][][TASK_ID:81984b7f083ed690][TRACE_ID:a4f5c24e99a4c2d8;JOB_ID:b0f4954143a3b8b6][plc.id:169434fd,asset.id:641cf073,pcs.id:cdd721f7] c.e.b.d.ddboost.DDBoostAdapter.copyFileSetRetentionTime(1738) - Unable to setRetentionTime for srcStorageUnit=StorageUnitName, dstStorageUnit=StorageUnitName, dstFilePath=PLCTLP-xxxxxxx-xxxx-xxxx-xxxx-xxxxxxxxxxxx/Client_HostName/14/2.0/data_ss/MSSQL2%3aUsersRestore/FULL/_ts10k_170403/1704038853.ss replmgr.log: 2024-01-08T00:15:00.378Z INFO [] [replmgr-job-worker-thread-736] [00000000-0000-4000-a000-000000000000][][TASK_ID:81984b7f083ed690][TRACE_ID:a4f5c24e99a4c2d8;JOB_ID:b0f4954143a3b8b6][plc.id:169434fd,asset.id:641cf073,pcs.id:cdd721f7] c.e.b.d.ddboost.DDBoostAdapter.skipRetentionTime(1765) - comparing existing retention-time=1970-01-01T00:00:00Z updateTo=2031-01-09T00:00:00Z replmgr.log: 2024-01-08T00:15:00.378Z INFO [] [replmgr-job-worker-thread-736] [00000000-0000-4000-a000-000000000000][][TASK_ID:81984b7f083ed690][TRACE_ID:a4f5c24e99a4c2d8;JOB_ID:b0f4954143a3b8b6][plc.id:169434fd,asset.id:641cf073,pcs.id:cdd721f7] c.e.b.d.ddboost.DDBoostAdapter.setRetentionTime(1776) - setting retention-time=2031-01-09T00:00:00Z for SU=StorageUnitName filepath=PLCTLP-xxxxxxx-xxxx-xxxx-xxxx-xxxxxxxxxxxx/Client_HostName/14/2.0/data_ss/MSSQL2%3aUsersRestore/FULL/_ts10k_170403/1704038854.ss
Cause
På Data Domain er den maksimale opbevaringsperiodeværdi, der er indstillet på MTree, lavere end den værdi, der er konfigureret i PowerProtect Data Manager Protection Policy.
Resolution
Du kan løse dette problem ved at kontrollere den maksimale opbevaringsperiode, der er konfigureret på det Data Domain-MTree, der bruges til replikeringsdestinationen. Hvis maks. opbevaringsperiode er under den værdi, der er konfigureret i beskyttelsespolitikken, skal du ændre den maksimale opbevaringsperiode, så den opfylder de krav, der er defineret i beskyttelsespolitikken.
Du kan finde flere oplysninger om, hvordan du kontrollerer værdien for den maksimale opbevaringsperiode for MTree, og hvordan du ændrer denne værdi, i Knowledge Base-artikel 79803, Data Domain: Ofte stillede spørgsmål om fastholdelseslås
Du kan finde flere oplysninger om, hvordan du kontrollerer værdien for den maksimale opbevaringsperiode for MTree, og hvordan du ændrer denne værdi, i Knowledge Base-artikel 79803, Data Domain: Ofte stillede spørgsmål om fastholdelseslås
Affected Products
PowerProtect Data Manager Appliance, PowerProtect Data Manager, PowerProtect Data Manager Essentials, PowerProtect Data Manager Software, PowerProtect DM5500Article Properties