GW 作業記錄檔中的 PowerFlex 3.x 誤導性事件
Summary: 在 GW 上使用「在主機上執行指令檔」功能時,operations.log回報誤導性事件
This article applies to
This article does not apply to
This article is not tied to any specific product.
Not all product versions are identified in this article.
Symptoms
劇本
在 GW 上使用「在主機上執行指令檔」功能時,管理員可能只想將指令檔套用到少數 SDS。operations.log 檔案會報告它會在所有 SDS 上執行指令檔,而非選取的 SDS。
症狀
下面是該方案的範例:
節點 1 = 56.56.56.21, 57.57.57.21
節點 2 = 57.57.57.23, 56.56.56.23
節點 3 = 57.57.57.22, 56.56.56.22
Patch_script僅上傳到節點 1。
Operations.log顯示Patch_script僅存在於節點 1 上:
2021-06-23 15:41:59,312 [scheduler-1] INFO operations - ValidatePatchScriptExistenceEnd[56.56.56.21, 57.57.57.21]completed{2}{3}{4}{5}{6}{7}{8}{9}{10}{11}{12}{13}{14}{15}{16}{17}{18}{19}{20}{21}
2021-06-23 15:42:01,312 [scheduler-1] INFO operations - ValidatePatchScriptExistenceFailed[57.57.57.23, 56.56.56.23]{1}{2}{3}{4}{5}{6}{7}{8}{9}{10}{11}{12}{13}{14}{15}{16}{17}{18}{19}{20}{21}
2021-06-23 15:42:01,312 [scheduler-1] INFO operations - ValidatePatchScriptExistenceFailed[57.57.57.22, 56.56.56.22]{1}{2}{3}{4}{5}{6}{7}{8}{9}{10}{11}{12}{13}{14}{15}{16}{17}{18}{19}{20}{21}
Operations.log錯誤地報告 Patch_script 是在節點 2 和節點 3 上執行,而他們沒有上傳Patch_script:
021-06-23 15:42:16,912 [scheduler-1] INFO operations - Run patch script on node [57.57.57.22, 56.56.56.22] with timeoutMsec 900,000 has ended with result of completed 2021-06-23 15:42:17,111 [scheduler-1] INFO operations - exit of SDS [57.57.57.22, 56.56.56.22] from maintenance mode has completed with result of completed ... 2021-06-23 15:42:42,112 [scheduler-1] INFO operations - Run patch script on node [57.57.57.23, 56.56.56.23] with timeoutMsec 900,000 has ended with result of completed 2021-06-23 15:42:42,311 [scheduler-1] INFO operations - exit of SDS [57.57.57.23, 56.56.56.23] from maintenance mode has completed with result of completed
影響
無影響 Patch_script將僅在上傳它的伺服器上運行。
Cause
這是軟體記錄問題。
Resolution
opeartions.log檔中的誤導性事件可以安全地忽略。
受影響的版本
3.6.0.1 及更舊版本
3.5.1.3 及更舊版本
已修正問題的版本
3.6.0.2
3.5.1.4
Affected Products
PowerFlex Software, VxFlex Ready Node, Ready Node SeriesArticle Properties
Article Number: 000195565
Article Type: Solution
Last Modified: 11 Apr 2025
Version: 4
Find answers to your questions from other Dell users
Support Services
Check if your device is covered by Support Services.